AL-1556/1566  TEST COMMAND, FAX SOFT SWITCH, TROUBLE CODES  10 - 25
50
01
Lead edge image position 
(LEAD EDGE)
[Function]
Used to adjust the copy image position and the lead edge void amount on copy paper. The adjust-
ment is made by adjusting the image scan start position at 100% and the print start position (resist
roller ON timing). When this test command is executed, the current set value is displayed in 2 digits.
(Center value: 50)
When [
/
] key is pressed, the setting mode and the display are changed. 
Enter the adjustment value and press [START] key to save the set value and make a copy. 
When the adjustment is made by the main cassette paper feed, the adjustment values of all the paper
feed ports become the same. (When the set value is increased by 1, shift is made by 0.1mm.)
(*): Support for the installation models. For non-installation models, skip.
[Adjustment procedure]
1) Set the print start position (A: COPY mode lamp ON), the lead edge void amount (B: PRINT mode
lamp ON), the scan start position (C: SCAN mode lamp) to zero, and make a copy of the scale at
100%.
2) Measure the image loss (Rmm) of the scale.
Set C = 10 x R (mm). (Example: Set to 40.)
When the value of C is increased by 10, the image loss is decreased by 1mm. (Default: 50)
3) Measure the distance (Hmm) from the paper lead edge to the image print start position. 
Set A = 10 x H (mm). (Example: Set to 50.)
When the value of A is increased by 10, the image lead edge is moved to the paper lead edge by
1mm. (Default: 50).
4) Set the lead edge void amount to B = 50 (2.5mm). (Default: 50)
When the value of B is increased by 10, the void is extended by about 0.1mm. (For 25 or less,
however, the void amount is regarded as 0.)
The SFP adjustment is made by adjusting the SPF image scan start position after OC adjustment.
When paper is discharged, the shifter is operated.
(Example)
[Operation]
The operation is similar to test command 46-01.
Main 
code
Sub 
code
Contents
Details of function/operation
Mode
Display item
Default
LED
Print start position (Main cassette 
paper feed)
TRAY1
50
COPY mode lamp
Main cassette lamp
(*) Print start position (2nd 
cassette paper feed)
TRAY2
50
COPY mode lamp
2nd cassette lamp
Print start position (Manual paper 
feed)
MFT
50
COPY mode lamp
Manual feed lamp
Image lead edge void amount
DEN-A
50
PRINT mode lamp
Image scan start position 
RRC-A
50
SCAN mode lamp
Image rear edge void amount
DEN-B
50
COPY mode lamp
PRINT mode lamp
SCAN mode lamp
5mm
10mm
Distance from the paper lead edge 
to the image lead edge, H = 5mm
Image loss, R = 4mm
AL-1556/1566  TEST COMMAND, FAX SOFT SWITCH, TROUBLE CODES  10 - 26
50
06
Copy lead edge position 
adjustment (SPF/RSPF) 
(SPF/RSPF EDGE)
[Function]
Used to adjust the SPF copy lead edge.
When the adjustment value of the document scan position adjustment is increased by 1, the scan
start timing is advanced by 0.1mm. 
The print result is shifted to the opposite direction of the scan start position.
The adjustment mode can be changed by pressing [
/
] key. (Adjustment range: 1 – 99, Default:50)
When scanning a back surface of document, the mode must be changed to operate the RSPF by
pressing [2-SIDED COPY] key.
(*) : Support for the installation models. For non-installation models, skip.
When there is no document in the SPF, copy is inhibited.
When paper is discharged, the shifter is operated.
[Operation]
The operation is similar to test command 46-01.
10
Print center offset 
adjustment (PRT.OFF-
CENTER)
[Function]
Used to adjust the center offset position of copy images on copy paper and that in scanning docu-
ment.
When this test command is executed, the current set value is displayed.
Enter the adjustment value and press [START] key to save the setting and make a copy. (When the
set value is changed by 1, the center is shifted by 0.1mm.)
When the adjustment value is increased, the center is shifted to right. When decreased, the center is
shifted to left.
The modes can be selected by pressing [
/
] key.
When the set value is changed largely, the area outside the shading area may be scanned to cause
black streaks on the edges. When the RSPF is used, select the mode for use of the RSPF by [2-
SIDED COPY] key.
(*) : Support for the installation models. For non-installation models, skip.
In the 2nd print center offset adjustment, print is made forcibly as 1to2/Short Edge from OC regard-
less of duplex setting.
When paper is discharged, the shifter is operated.
[Operation]
The operation is similar to test command 46-01.
12
Document feed off-center 
adjustment (ORG.OFF-
CENTER)
[Function]
Used to adjust document scan off-center adjustment.
The adjustment modes can be selected by pressing [
/
] key. (Adjustment range: 1 – 99, Default:50)
When the adjustment value is increased, the print result is shifted to left.
(*) : Support for the installation models. For non-installation models, skip.
When paper is discharged, the shifter is operated.
[Operation]
The operation is similar to test command 46-01.
Main 
code
Sub 
code
Contents
Details of function/operation
Mode
Display item
Default
LED
Front surface document scan position 
adjustment
SIDE1
50
COPY mode lamp
(*) Back surface document scan position 
adjustment
SIDE2
50
PRINT mode lamp
Rear edge void adjustment (SPF)
END
50
SCAN mode lamp
Mode
Display item
Default
LED
Print center offset (Main cassette paper 
feed)
TRAY1
50
COPY mode lamp
Main cassette lamp
(*) Print center offset (2nd cassette paper 
feed)
TRAY2
50
COPY mode lamp
2nd cassette lamp
Print center offset (Manual paper feed)
MFT
50
COPY mode lamp
Manual feed lamp
(*) 2nd print center offset (Main cassette 
paper feed) 
SIDE2
50
PRINT mode lamp
Main cassette lamp
Mode
Display item
Default
LED
Platen document scan 
OC
50
COPY mode lamp
(*) SPF document front scan
SPF
50
PRINT mode lamp
(*) RSPF document back scan 
RSPF
50
SCAN mode lamp
AL-1556/1566  TEST COMMAND, FAX SOFT SWITCH, TROUBLE CODES  10 - 27
50
18
Memory reverse position 
adjustment in duplex copy 
(DPLX REVERSE)
[Function]
When this test command is executed, the current set correction value is displayed.
Enter the correction value and press [START] key to save the entered correction value. (Correction
value range; 1 – 99, Default: 50)
For S-D mode front surface print and print of even paged in D-S mode, reverse memory copy opera-
tion is performed from the rear edge of documents. 
When, therefore, the print position adjustment of output images is required, adjust as follows: 
In the reverse memory coping, when the document scan is made in the arrow direction, the output
image is printed from the rear edge of scan image,
When, therefore, the print lead edge is shifted, set the reference chart so that the reference position is
on the rear edge, and use this test command to adjust the set value so that the print lead edge is
matched. 
Since printing is made from the image data most lately stored in memory to the lead edge data from
the print start position, the image lead edge adjustment is made by changing the end data position
stored in memory by the set value of this test command.
Since it is performed by changing the scan end position, the image position adjustment is made by
changing the scan end position and the end data stored in memory.
The initial value of duplex setting is "1to2/Long Edge" for the duplex model, or "2to1" for the simplex
model.
When paper is discharged, the shifter is operated.
[Operation]
The operation is similar to test command 46-01.
19
Duplex copy rear edge void 
adjustment (DPLX END 
EDGE)
[Function]
Used to adjust the rear edge void amount in duplex copy. 
When this test command is executed, the current set value is displayed in 2 digits. (Center value: 50.)
The adjustment modes can be selected by pressing [
/
] key. (Adjustment range; 1 – 99)
Enter the adjustment value and press [START] key to save the set value and make a copy. (The
paper information is cleared for every copy.)
When the set value is increased by 1, the void amount is increased by about 0.1mm.
The initial value for duplex setting is "1to2/Short Edge" for the OC/SPF setting, or "2to2" for the
RSPF setting.
When paper is discharged, the shifter is operated.
[Operation]
The operation is similar to test command 46-01.
Main 
code
Sub 
code
Contents
Details of function/operation
*1: Only when SPF/RSPF is installed. If installed, skipped.
Mode
Display item
Default
LED
OC memory reverse output position 
OC
50
COPY mode lamp
SPF memory reverse output position *1
SPF
50
PRINT mode lamp
Document transport direction
Document transport direction
Scan lead edge
Print lead edge
Lead edge void (1)
Print start position
Scan end position
(Default: Scan cut by void (1))   
Rear edge void
Print rear edge
Scan direction
Scan rear edge
Mode
Display item
Default
LED
Paper rear edge void amount
DEN-B
50
PRINT mode lamp
Print start position (Duplex back surface)
RRC-D
50
SCAN mode lamp
AL-1556/1566  TEST COMMAND, FAX SOFT SWITCH, TROUBLE CODES  10 - 28
51
02
Resist amount adjustment 
(RESIST ADJ.)
[Function]
Used to adjust the contact pressure of the main unit resist roller and the RSPF resist roller onto paper.
When this test command is executed, the current set value is displayed. 
The adjustment modes can be selected by pressing [
/
] key.
Enter the adjustment value with [10KEY] and press [START] key to save the set value and make a
copy.
(*): Support for the installation models. For non-installation models, skip.
[Operation]
The operation is similar to test command 46-01.
53
08
SPF scan position automatic 
adjustment (SPF AUTO)
[Function]
Place a black chart so that it covers the SPF scan glass and the OC glass together, and close the OC
cover.
When this test command is executed, the current adjustment value is displayed as the initial display.
Default is 1. Adjustment range is 1 – 99. Adjustment unit 1 = about 0.127mm
If the values are kept as the default values, SPF scan is not performed properly. The front area of
the proper scan position may be scanned.
In case of AUTO, press [START] key, and the mirror unit scans from the home position to the SPF
scan position with the adjustment value displayed. The SPF glass cover edge position is calculated
from the difference between the SPFG glass cover edge and the OC side document glass CCD out-
put level. If the adjustment is normal, the adjusted value is displayed. If abnormal, the error LED lights
up with the current set value displayed. 
During the error LED is lighted, when [START] key is pressed again, execution is performed again.
[Operation]
The operation is similar to test command 46-01.  (In MANUAL)
OK/ERR display in AUTO
61
03
HSYNC output check (LSU 
CHK)
[Function]
When [OK/START] key is pressed, HSYNC is performed and the polygon motor is rotated for 30sec. 
At that time, the COPY mode lamp is lighted for 100msec every time when HSYNC is detected.
[Operation]
Main 
code
Sub 
code
Contents
Details of function/operation
Mode
Display item
Default
LED
Main cassette paper fed
TRAY1
50
COPY mode lamp
Main cassette lamp
(*) 2nd cassette paper feed
TRAY2
50
COPY mode lamp
2nd cassette lamp
Manual paper feed
MFT
50
COPY mode lamp
Manual feed lamp
(*) RSPF document paper feed 
(Front surface)
SIDE1
50
COPY mode lamp
PRINT mode lamp
SCAN mode lamp
(*) RSPF document paper feed 
(Back surface) 
SIDE2
50
COPY mode lamp
PRINT mode lamp
(*) Duplex back surface
DUP-2
50
PRINT mode lamp
SCAN mode lamp
Mode
Display item
Default
LED
SPF scan position auto adjustment 
AUTO
1
COPY mode lamp
SPF scan position manual adjustment 
MANU
1
PRINT mode lamp
<When OK>
<When ERR>
53-08 SPF AUTO
AUTO  100% **    OK
53-08 SPF AUTO
AUTO  100% **    ERR
1) Initial display
61-03 LSU CHK