DOWNLOAD Sharp AL-1566 (serv.man13) Service Manual ↓ Size: 450.17 KB | Pages: 72 in PDF or view online for FREE

Model
AL-1566 (serv.man13)
Pages
72
Size
450.17 KB
Type
PDF
Document
Service Manual
Brand
Device
Copying Equipment / Test command, fax soft switch, trouble codes
File
al-1566-sm13.pdf
Date

Sharp AL-1566 (serv.man13) Service Manual ▷ View online

AL-1556/1566  TEST COMMAND, FAX SOFT SWITCH, TROUBLE CODES  10 - 13
26
38
Cancel of stop at drum life 
over (DRUM LIFE END)
[Function]
When this test command is executed, the current setting is displayed. Enter the code number corre-
sponding to the desired setting and press [OK/START] key to save the setting.
[Operation]
The operation is similar to test command 21-01.
39
Memory capacity check 
(MEM.CHK)
[Function]
When the test command is executed, the currently installed SDRAM of the main unit is displayed.
[Operation]
40
Polygon motor OFF time 
setting (Time required from 
completion of printing to 
turning OFF the motor) (LSU 
MOTOR OFF)
[Function]
When this test command is executed, the current setting is displayed. Enter the code number corre-
sponding to the desired setting and press [OK/START] key to save the setting.
[Operation]
The operation is similar to test command 21-01.
42
Transfer ON timing control 
setting (TC ON TIMING)
[Function]
When this test command is executed, the currently set value of the transfer ON timing is displayed
(initial display), and the set value is saved. (Setting range: 0 – 9, Default: 5)
The default “5” of transfer ON timing is “330ms passed from PS release.”
When set to “0,” it is the same as setting to “5.”
[Operation]
The operation is similar to test command 21-01.
Main 
code
Sub 
code
Contents
Details of function/operation
Code number
Setting
Display item
Remark
0
Stop at drum life over
STOP
Default
1
Cancel of stop at drum life over
NONSTOP
Code number
Setting
Remark
8
8  MBYTE
1) Memory capacity display 
26-39 MEM.CHK
8 MBYTE
Code number
Setting
Display item
Remark
0
0sec
0  SEC.
1
30sec
30 SEC.
Default
2
60sec
60 SEC.
3
90sec
90 SEC.
Code
Setting
Remark
0
0  msec
1
–40 msec
2
–30 msec
3
–20 msec
4
–10 msec
5
0 msec
Default
6
+10 msec
7
+20 msec
8
+30 msec
9
+40 msec
AL-1556/1566  TEST COMMAND, FAX SOFT SWITCH, TROUBLE CODES  10 - 14
26
43
Side void amount setting 
(SIDE VOID)
[Function]
When this test command is executed, the currently set code of the side void quantity is displayed (ini-
tial display), and the set data are saved. (Setting range: 0 – 10, Default: 4 (= One side 2.0mm)) 
When the adjustment value is increased by 1, the side void is changed as follows:
Side void adjustment: The side void is increased by 0.5mm. (The side void of “Set value x 0.5mm”
is made.)
[Operation]
62
Energy-save mode copy 
lamp setting (C-LAMP E-S)
[Function]
Used to set half-ON /OFF of the copy lamp in the pre-heat mode.
When this test command is executed, the current set code number is displayed. Enter the desired
code number and press [OK/START] key to save the setting.
[Operation]
The operation is similar to test command 21-01.
30
01
Paper sensor status display 
(P-SENSOR)
[Function]
The paper sensor status is displayed on the LCD.
Since the manual paper feed sensor is a single bypass sensor, its status is not displayed.
The width sensor is available only in the FAX models.
[Operation]
Main 
code
Sub 
code
Contents
Details of function/operation
9
Code
Setting
Remark
0
0  mm
1
0.5  mm
2
1.0  mm
3
1.5  mm
4
2.0 mm
Default
5
2.5  mm
6
3.0  mm
7
3.5  mm
8
4.0  mm
9
4.5  mm
10
5.5 mm
1) Initial display
2) [10KEY]
3) [OK/START]
26-43 SIDE VOID
            4( 0-10)
26-43 SIDE VOID
            5( 0-10)
26-43 SIDE VOID
            5( 0-10)
Code number
Setting
Display item
Remark
0
Copy lamp OFF
OFF
1
Copy lamp half-ON
ON
Default
Sensor
Display item
Remark
Paper exit sensor
POD
No. 1 tray paper width sensor
PD1
Paper entry sensor
PPD1
Duplex sensor
PPD2
No. 2 tray paper feed sensor
PPD3
New drum cartridge sensor
DRST
1) Initial display
2) When sensor ON
30-01 P-SENSOR
30-01 POD  PD1  PD2
PPD1 PPD2 PPD3 DRST 
AL-1556/1566  TEST COMMAND, FAX SOFT SWITCH, TROUBLE CODES  10 - 15
41
06
OC cover float detection 
level (OC FLOAT LEVEL)
[Function]
When this test command is executed, the current set value is displayed. When [OK/START] key is
pressed, the mirror base unit moves to the SPF scan position to acquire the OC cover float detection
level.
When the mirror base unit returns to the home position, the acquired value is displayed.
If the detection level is not acquired, ERR display is made. (Default: 0)
Note that, this test command must be executed with the OC cover closed.
If the value is 0, float detection is not performed in normal jobs.
[Operation]
43
01
Fusing temperature setting 
(Normal copy) (FU TEMP)
[Function]
When this test command is executed, the current set code number is displayed. Press [
/
/10KEY]
key to change the setting and press [OK/START] key to save the setting into the EERPOM. The
machine goes into the sub code entry standby mode.
[Operation]
The operation is similar to test command 21-01.
04
Fusing temperature setting 
in multi coy (FU TEMP 
MULTI)
[Function]
For 20th sheet or later in multi copy, the fusing temperature is automatically changed from the temper-
ature set with test command 43-1 to the temperature set with this test command. 
When this test command is executed, the current set code number is displayed. Enter the code num-
ber and press [OK/START] key to change the setting.
[Operation]
The operation is similar to test command 21-01.
Main 
code
Sub 
code
Contents
Details of function/operation
1) Initial display
2) [OK/START]
41-06 OC FLOAT LEVEL
               0    
41-06 OC FLOAT LEVEL
EXECUTING...
<Canceling - when C/CA key is pressed->
After canceling, the machine goes into the sub code entry
standby mode.
3) When the level is acquired:
3) When the level is not acquired:
THE JOB IS BEING
CANCELED.
41-06 OC FLOAT LEVEL
             **** OK 
41-06 OC FLOAT LEVEL
             **** ERR
Code
Set temperature (°C)
Remark
0
160
1
165
2
170
3
175
4
180
5
185
6
190
Default
7
195
8
200
Code
Set temperature (°C)
Remark
0
155
1
160
2
165
3
170
Default
4
175
5
180
AL-1556/1566  TEST COMMAND, FAX SOFT SWITCH, TROUBLE CODES  10 - 16
43
05
Fusing temperature setting 
in duplex copy (FU TEMP 
DPLX)
[Function]
In the case of duplex copy, the shift temperature set with this test command is applied to the fusing
temperature.
When this test command is executed, the current set code number is displayed. 
Enter the desired code number and press [OK/START] key to save the setting.
[Operation]
The operation is similar to test command 21-01.
09
Postcard size paper fusing 
control setting (FU CTR P-
CARD) (Japan model only)
[Function]
When this test command is executed, the current set code number is displayed. 
Enter the desired code number and press [OK/START] key to save the setting.
Setting" is default for Japan. However, there is no schedule for production of the Japan model.
[Operation]
The operation is similar to test command 21-01.
11
Postcard size paper fusing 
temperature setting (FU 
TEMP P-CARD) (Japan 
model only)
[Function]
When this test command is executed, the current set code number is displayed. 
When [
/
/10KEY] key is pressed, setting is changed. When [OK/START] key is pressed, setting is
written into the EEPROM. The machine goes into the sub code entry standby mode. 
Applied only to the Japan model. However, there is no schedule to produce the Japan model. Set-
ting is reflected only when ON with test command 43-09.
[Operation]
The operation is similar to test command 21-01.
14
Fusing start temperature 
setting (FU TEMP START)
[Function]
When this test command is started, the currently set code number is displayed.
Press [
/
/10KEY] to switch the setting, and press [OK/START] key to save it to the EEPROM. The
machine goes to the sub code entry standby mode.
[Operation]
The operation is similar to test command 21-01.
Main 
code
Sub 
code
Contents
Details of function/operation
Code
Shift temperature (°C)
Remark
0
±0
Default
1
-8
2
-6
3
-4
4
-2
5
±0
6
+2
7
+4
8
+6
9
+8
Code
Shift temperature (°C)
Display item
Remark
0
Cancel
OFF
Default
1
Setting
ON
Code
Shift temperature (°C)
Remark
0
160
1
165
2
170
3
175
4
180
5
185
6
190
7
195
Default
8
200
Code
Set temperature (°C)
Remark
0
160
1
165
2
170
3
175
4
180
5
185
6
190
7
195
Default
8
200
Page of 72