DOWNLOAD Sharp PN-U553 (serv.man2) Service Manual ↓ Size: 5.49 MB | Pages: 99 in PDF or view online for FREE

Model
PN-U553 (serv.man2)
Pages
99
Size
5.49 MB
Type
PDF
Document
Service Manual
Brand
Device
Monitor
File
pn-u553-sm2.pdf
Date

Sharp PN-U553 (serv.man2) Service Manual ▷ View online

PN-U553/U473/U423 SERVICE MENU/VARIOUS SETTING TOOL OPERATING PROCEDURES 4 - 1 
 
CHAPTER 4. SERVICE MENU/VARIOUS SETTING TOOL OPERATING PROCEDURES 
 
1.
 
OPERATING PROCEDURES     
                                                     
After pressing [SIZE] key on remote control for approx. 5 seconds (LED is flashing, "F" appears on upper left of the screen), 
and then pressing [BRIGHT -(
←)] [VOL -(↓)] [BRIGHT +(→)][VOL +(↑)] keys in series, SERVICE MENU1 will be 
displayed.   
 
 
-1.SERVICE MENU 1   
Model name, S/N., firmware version/check sum, usage time etc 
are indicated.   
1)  When entering SERVICE MENU, the following screen 
appears: 
 
2)  When selecting MODEL/VERSION, the following screen 
appears: 
 
3) 
When selecting USAGE TIME, the following screen appears: 
 
[NOTE] 
*Right after turning ON the main power switch, “Get 
checksum. Please wait…” is displayed as check sum for a 
while, and then the result is displayed.       
* When ADJUSTMENT LOCK is set to the option other than 
“OFF”, "F" is indicated in red.    When OSA DISPLAY is set to 
“OFF”, it is indicated in blue.    In other cases, it is indicated 
in green.    (Red is prioritized as the color of "F" .) 
 
 
 
 
[MODEL/VERSION] 
MODEL 
Model name 
S/N 
Serial number 
VER(MAIN) 
Version of the main firmware 
C/S(MAIN) 
Check sum of the main firmware (capital character) 
VER(SUB) 
Version of the sub firmware 
C/S (SUB) 
Check sum of the sub firmware (capital character) 
VER(LAN) 
Version of the firmware for LAN control 
C/S (LAN) 
Check sum of the firmware for LAN control (capital 
character) 
VER(CPLD) 
Version of CPLD 
[USAGE TIME] 
RESETABLE ON 
Indicate the power-ON time (can reset) 
UNRESETABLE ON 
Indicate the power-ON time (cannot reset) 
PN-U553/U473/U423 SERVICE MENU/VARIOUS SETTING TOOL OPERATING PROCEDURES 4 - 
 
- 2SERVICE MENU 2 
AGING AGING 
→ See "2. AGING" 
CALIBRATION 
Auto adjust GAIN and OFFSET only for DVI-I 
(analog) /D-SUB [RGB]、DSUB[ 
COMPONENT]/D-SUB [VIDEO]. 
→ See "3. CALIBRATION" 
FACTORY RESET 
Reset USAGE TIME and OPERATION LOG 
etc in addition to USER ADJUSTMENT 
VALUE. 
→ See "4.FACTORY RESET" 
WHITE BALANCE SETTING 
→ See "8. How to Adjust White Balance "   
FIRMWARE UPDATE 
Run the system in Update Mode 
SOG SYNC THRESHOLD LEVEL 
Set up the threshold level of synchronization 
signal of SOG 
MODEL TYPE 
Switching of the destination: 
JP : Mode l for Japan 
US:Model for North America   
EU:Model for Europe   
 
1)  Select "SERVICE2" with [VOL - (
↓)] key while displaying 
“SERVICE MENU1” screen.    Press [ENTER] key. 
 
2)Select the setting item with [VOL - (
↑)], [VOL + (↓)] keys. 
3)Make adjustment with [BRIGHT - (
←)],[BRIGHT + (→)] keys.     
As for items with => mark, press [ENTER] key to go on to the next 
screen.  
4)  Press [MENU] key to exit. 
PN-U553/U473/U423 SERVICE MENU/VARIOUS SETTING TOOL OPERATING PROCEDURES 4 - 
 
1-3SERVICE MENU 3 
 
STANDBY OPTION 
Whether to set up the condition that the backlight is 
turned OFF before switching to Input signal Waiting 
Mode and before switching to Standby Mode 
0: Not set up 10~720: set up by 10 minutes. 
*This setting is activated when turning ON the main 
power switch next time. 
BACKLIGHT OFF COLOR 
Select the color during the operation when the 
backlight is turned OFF. 
WHITE/BLACK PERIOD 
Set up the time interval (ms) between WHITE and 
BLACK when BACKLIGHT OFF COLOR is 
WHITE/BLACK. 
SYSTEM LOG INITIALIZE 
Initialize System Log. 
TEMP LOG INITIALIZE 
Initialize Temperature Log. 
1) 
Select "SERVICE 3" with [VOL - (↓)] key while displaying 
“SERVICE MENU1” screen.    Press [BRIGHT + (→) ] key. 
 
* Items inside the frame are supported with R/C. 
 
2)Select the setting item with [VOL - (
↑)], [VOL + (↓)] keys. 
3)Press [ENTER] key to go on to the next screen. 
4)Press [MENU] key to exit. 
 
[MEMO] 
-
 
Can not change the model name in the PN-U series. 
-
 
Can not be set in "SERVICE MENU" serial number. 
 
1-4SERVICE MENU 4 
 
THERML 1 
Check result with Thermal sensor1 and 
its value are indicated.    Value is taken 
every 5-second and then updated. 
THERML 2 
Check result with Thermal sensor2 and 
its value are indicated.    Value is taken 
every 5-second and then updated. 
BRIGHT DOWN LAST TIME 
USAGE TIME, date & time, and the 
temperature at the time when the 
backlight is down previous time are 
indicated.  
POWER OFF LAST TIME 
USAGE TIME, date & time, and the 
temperature at the time when the power 
is turned OFF due to the high 
temperature previous time are indicated. 
1)  Select "SERVICE 3" with [VOL - (↓)] key while displaying 
“SERVICE MENU1” screen.    Press [BRIGHT +(→) ] key. 
 
2)Select the setting item with [VOL - (
↑)], [VOL + (↓)] keys. 
3)Press [ENTER] key to go on to the next screen. 
4)Press [MENU] key to exit. 
 
PN-U SERVICE MENU/VARIOUS SETTING TOOL OPERATING PROCEDURES 4 - 4 
 
2.
 
AGING                                                                               
1) Display SERVICE MENU 2. 
2) Select "AGING" with [VOL - (
↑)], [VOL + (↓)] keys.    Press [BRIGHT +(→) ] key. 
3) AGING screen appears. 
 
Color of whole screen automatically changes every 3 seconds. 
 
 
4) When finishing AGING, set this to OFF. 
3.
 
CALIBRATION                                                                         
Make adjustment of GAIN and OFFSET of A/D converter with Input modes below: 
 ANALOG 
mode 
 
 
D-SUB 
  COMPONENT mode   
COMPONENT terminal 
 
VIDEO mode     
 
VIDEO terminal 
1) 
Switch the Input mode to be adjusted with [INPUT] key. 
2) 
Show the video signal for adjustment on the screen. 
[NOTE] 
 
Be sure to make adjustment using the video signal in the table below: 
 
Calibration result differs between DVH (Analog) and D-SUB[RGB].    Be sure to make adjustment using each input mode. 
Input Mode 
Signal Type 
Input Signal Level 
(Adjust to standard value) 
Signal Timing 
Input Image 
D-SUB 
PC ANALOG signal 
RGB level:0.7 Vp-p 
1920×1080 60Hz 
or XGA(1024x768)
60Hz 
Adjustment image displayed by executing 
Adj_uty.exe in CD-ROM supplied with the 
product or the image with RGB WHITE 
0~255 gradation being indicated. 
COMPONENT COMPONENT 
signal 
Y level:0.7 Vp-p 
(From Pedestal to 
White) 
Pb/Pr level:0.7 Vp-p 
1080i 60Hz 
Full color bar (WHITE100%/ Degree of 
Color saturation 100%) 
*Recommended signal generator: 
ASTRODESIGN Products VG-849, 
VG-859 
 
 
Page of 99
Display

Click on the first or last page to see other PN-U553 (serv.man2) service manuals if exist.