Sharp PN-R603 Handy Guide ▷ View online
PN-R603/R703 Installation Guidelines <Rev1.0> February 2013
CONFIDENTIAL
Precautions for carrying
16
Precautions for carrying
Carrying the display with wheeled cart needs at least 2 people.
-Please carry package with a wheeled cart.
( Carrying the package with a wheeled cart needs at least 2 people. )
- Please do not carry this display with vertical orientation.
Please carry it with horizontal orientation.
-The package can be put temporality-vertical orientation when carrying with the elevator.
Please do not carry
the display with
vertical orientation.
the display with
vertical orientation.
Width(mm)
Depth(mm) Height(mm) Weight(kg)
PN-R603
1,630
285
960
42(approx.)
PN-R703
1,835
286
1,083
53(approx.)
<Packing size>
Elevator size :
Width : more than 1,400mm
Depth : more than 1,400mm
800mm
2,100mm
×
The package can be put temporality-vertical
orientation when carrying with the elevator.
orientation when carrying with the elevator.
PN-R603/R703 Installation Guidelines <Rev1.0> February 2013
CONFIDENTIAL
17
Precautions for installing protection glass
Precautions for installing protection glass
Please read deeply the setup manual for
PN-ZH603/ZH703
when installing them.
- After installing the protection glass, the range temperature for around the display must be within
0 - 35℃
.
- Minimum 2 persons are required for installing the protection glass. It is big and heavy so please install it carefully.
- The protection glass for PN-ZH603/ZH703 is attached with a frame but for PN-E802/E702/E602/E601/E521/E471R/E421 have
only protection glass.
only protection glass.
- Please wear clean gloves for installing the protection glass to prevent the glass and LCD panel from fingerprints or dirt.
- Please make sure all the screws are lock tight with screwdriver. Do not use impact driver.
- Be aware that after installing the protection glass, you can no longer use the original display package for shipment.
Protection Glass
(with frame)
Protection Glass
Display
Protection Glass 【PN-ZH603/ZH703】
<Reference>
Protection Glass of PN-E802/E702/
E602/E601/E521/E471R/E421
The structure for the model above is to lay the
display facing up, remove the front bezel, attach
the protection glass to the display and reattach
the front bezel. This is different for model PN-
R603/R703.
display facing up, remove the front bezel, attach
the protection glass to the display and reattach
the front bezel. This is different for model PN-
R603/R703.
- The structure for protection
glass with frame is to overlay the
glass to the display.
- The screws for this glass are
from the side of the display so it is
possible to install it for both wall-
mounted and with a stand.
glass with frame is to overlay the
glass to the display.
- The screws for this glass are
from the side of the display so it is
possible to install it for both wall-
mounted and with a stand.
Display
PN-R603/R703 Installation Guidelines <Rev1.0> February 2013
CONFIDENTIAL
18
PN-R603/R703 Installation Guidelines <Rev1.0> February 2013
CONFIDENTIAL
18