Sharp PN-R603 Handy Guide ▷ View online
PN-R603/R703 Installation Guidelines <Rev1.0> February 2013
CONFIDENTIAL
12
Precautions for orientation
About orientation
- Only vertical installation perpendicular to level surface is recommended.
-The limitation of the inclination angle is between 0 to 20 degrees upward/downward.
Only vertical installation
is recommended.
Within 20
degrees
Installing with inclination more than
20 degrees is impossible.
More than 20
degrees
○ × ×
More than 20
degrees
Within 20
degrees
○ ○
PN-R603/R703 Installation Guidelines <Rev1.0> February 2013
CONFIDENTIAL
13
Precautions for opening package
Precautions for Opening package
- Please open the package with at least
2 persons
.
- Remove joints from the package. (4 points)
-Take the upper part of the package off, and remove the display from the package.
Please remove joint directed downwards with
keeping holding inner tabs from each side.
keeping holding inner tabs from each side.
Please remove 4 joints which attached on
lower parts of the package.
Lift up the upper part of the package and take
off it.
lower parts of the package.
Lift up the upper part of the package and take
off it.
Please take package materials off and remove
the display from the packaging bag.
the display from the packaging bag.
PN-R603/R703 Installation Guidelines <Rev1.0> February 2013
CONFIDENTIAL
Precautions in installing and handling 1
Caution for Installing
Prior to installing the PN-R603/R703, please refer to following items carefully in order to use PN-R603/R703 for long term reliable service.
- Please use a mounting bracket which can support 4 times weight of the display. The wall on which displays are mounted must support 4 times total
weight of the display and mounting bracket (etc. concrete wall / concrete pillar).
- Only vertical installation perpendicular to level surface is recommended, and the limitation of the inclination angle is between 0 to 20 degrees
upward/downward.
- Usable temperature range of this display is 0℃-40℃. Using in other condition may cause failure and deterioration.
Please keep enough space to avoid heating.
- Please set this display keeping out of direct sunlight. It may cause failure and deterioration.
- It is necessary to take measures against dust such as regular cleaning in a dusty area.
- For safety, please give measures for preventing fall of display.
- The ground connection is necessary when the power plug is connected.
weight of the display and mounting bracket (etc. concrete wall / concrete pillar).
- Only vertical installation perpendicular to level surface is recommended, and the limitation of the inclination angle is between 0 to 20 degrees
upward/downward.
- Usable temperature range of this display is 0℃-40℃. Using in other condition may cause failure and deterioration.
Please keep enough space to avoid heating.
- Please set this display keeping out of direct sunlight. It may cause failure and deterioration.
- It is necessary to take measures against dust such as regular cleaning in a dusty area.
- For safety, please give measures for preventing fall of display.
- The ground connection is necessary when the power plug is connected.
Please ask the professional dealer/contractor if you can’t keep the ground connection.
-
Please refer to the “SAFETY PRECAUTIONS”, “TIPS AND SAFETY INSTRUCTION” and “MOUNTING
PRECAUTIONS” which is described in the operation manual of the display as well.
-
Please be careful that the warranty can’t be applied if these precautions are not kept.
14
The display surface is made of glass.
Please do not hold surface of the display.
Please do not hold surface of the display.
When installing or moving, please hold the
designated part as following left image.
Please do not hold surface, reception unit in left
below, designated part in back of the display.
It is possible to cause damage and malfunction of
display. Please be careful not to drop the display.
designated part as following left image.
Please do not hold surface, reception unit in left
below, designated part in back of the display.
It is possible to cause damage and malfunction of
display. Please be careful not to drop the display.
Precautions in installing and moving
PN-R603/R703 Installation Guidelines <Rev1.0> February 2013
CONFIDENTIAL
15
Precautions in installing and handling 2
Worker position, assignment of work and cautions at lifting up the display.
Please wear gloves and safety shoes when you lift up this display.
For lifting up the display
2 people(“60” inch) or 3 people(“70” inch)
is required.
Following the image below, please check the position and assignment for each worker.
WorkerA
(For “60” / ”70”);
Hold the side(short side) of the main
body with left hand.
hold the underside(long side) of the
main body with right hand.
body with left hand.
hold the underside(long side) of the
main body with right hand.
WorkerB
(For “60” / ”70”);
Hold the side(short side) of the main
body with right hand.
hold the underside(long side) of the
main body with left hand.
body with right hand.
hold the underside(long side) of the
main body with left hand.
PN-R603/R703 are no handle design, and it is
possible to hold any parts of bezel. When holding,
please hold the display with the bottom hand, and the
top hand hold to support the display balance.
Please install PN-
possible to hold any parts of bezel. When holding,
please hold the display with the bottom hand, and the
top hand hold to support the display balance.
Please install PN-
R603/R703 refer to “UP” mark label
in vertical orientation.
Width
(mm)
Depth
(mm)
Height
(mm)
Weight
(kg)
PN-R603
1,378
39.4
794
32(approx.)
PN-R703
1,578
39.4
916
43(approx.)
<Main body size>
This is reception unit.
Please do not hold it.
Please do not hold it.
WorkerC
(Only for ”70”);
Hold the top side(long side) of the main body with left hand.
hold the underside(long side) of the main body with right hand.
hold the underside(long side) of the main body with right hand.
“UP” mark label
Click on the first or last page to see other PN-R603 service manuals if exist.