PN-L702B IMPORTANT INFORMATION FOR SERVICING THE DISPLAY
 3 – 1
CHAPTER 3.  IMPORTANT INFORMATION FOR SERVICING THE DISPLAY 
1. I/F PWB, LCD MODULE, PARTS REPLACEMENT PROCEDURES
The following information as well as user setting information are saved to the EEPROM (IC1007) controlled by main firmware and the EEPROM
(IC401) controlled by sub firmware.
<INFORMATION STORED IN THE EEPROM’S (IC1007) CONTROLLED BY THE MAIN FIRMWARE.>
n
SERIAL NUMBER
n
USAGE TIME
*1
n
WHITE BALANCE SETTING VALUE
*1
n
GAMMA SETTING VALUE
n
CALIBRATION SETTING VALUE
n
TEMPERATURE MONITOR SETTING INFORMATION
*
1
This information is linked with the LCD module.
<INFORMATION STORED IN THE EEPROM (IC401) CONTROLLED BY THE SUB FIRMWARE.>
n
MAC ADDRESS
Therefore, when the I/F PWB, the LCD module, IC1007 is replaced, initialization and setting must be performed according to necessity. 
In addition, after completion of the work, perform “ALL RESET”.
CAUTION
n
Since the MAC address is stored in the IC401, it must not be replaced in servicing. 
There is no replacement part setting.
1 - 1. INFORMATION ITEMS
MODEL NAME
In some cases, the model name to be set may be different.
3Refer to page 4 - 8  "6 - 2. MODEL NAME SETTING FUNCTION".
3Refer to page 4 - 24  "14. MODEL NAME SETTING PROCEDURES".
SERIAL NUMBER
The machine has its own serial number which is described on the nameplate at the back of the machine. 
3Refer to page 4 - 9  "6 - 3. SERIAL NUMBER SETTING FUNCTION".
3Refer to page 4 - 22  "12. SERIAL NUMBER WRITING PROCEDURES".
USAGE TIME
This information is linked with the LCD module. When replacing the I/F PWB, read the information before replacement, 
and write it to the new I/F PWB after replacement.
3Refer to page 4 - 9  "6 - 4. USAGE TIME SETTING FUNCTION".
3Refer to page 4 - 23  "13. USAGE TIME SETTING PROCEDURE".
WHITE BALANCE 
SETTING VALUE
This information is linked with the LCD module. When replacing the I/F PWB, read the information before replacement, 
and write it to the new I/F PWB after replacement.
Execute resetting when the LCD module is replaced. 
3Refer to page 4 - 13  "8. WHITE BALANCE SETTING PROCEDURES BY OSD".
GAMMA 
SETTING VALUE
This value is linked with the LCD module. When replacing the I/F PWB, read this value before replacement and write it 
into the I/F PWB after replacement. When replacing the LCD module, reset this value. 
3Refer to page 4 - 18  "10. GAMMA SETTING PROCEDURES WITH THE OSD".
CALIBRATION 
SETTING VALUE
Since a service part I/F PWB has been adjusted, there is no need to set when replacing the I/F PWB.
Setting may be required depending on the replaced part.
3Refer to page 4 - 3  "3. CALIBRATION".
TEMPERATURE 
MONITOR SETTING 
INFORMATION
This is the setting information related to temperature watch.
Execute resetting when replacing the I/F PWB or the LCD module. 
 
3Refer to page 4 - 25  "15. TEMPERATURE MONITOR SETTING PROCEDURES".
MAC ADDRESS
The MAC address is the unique ID number assigned to the I/F PWB for LAN communication. 
The unique ID number is written into the I/F PWB (service part).
CHAPTER 3. IMPORTANT INFORMATION FOR SERVICING THE DISPLAY
PN-L702B IMPORTANT INFORMATION FOR SERVICING THE DISPLAY
 3 – 2
1 - 2. I/F PWB REPLACEMENT PROCEDURES
1 ) Read the following information from the monitor before replacement of the I/F PWB.
n
USAGE TIME
n
WHITE BALANCE VALUE
n
GAMMA SETTING VALUE
MEMO
n
If the machine does not operate before replacement and reading cannot be made, this procedure is not required. 
2 ) Replace the I/F PWB and execute FACTORY RESET. 
3Refer to page 4 - 5  "4. FACTORY RESET".
3 ) Each service part has the EDID written in it. If necessary, the EDID should be updated to the latest.
3Refer to page 5 - 9  "4. EDID WRITING PROCEDURES".
4 ) Each service part has the firmware written in it.  If necessary, the firmware should be updated to the latest.
3Refer to page 5 - 1  "1. MAIN FIRMWARE UPDATE PROCEDURE".
3Refer to page 5 - 4  "2. LAN MICROCONTROLLER FIRMWARE UPDATING PROCEDURES (PN-ZB01)".
5 ) Set the MODEL TYPE depending on the destination.
The default destination of service parts is “JP.”
3Refer to page 4 - 2  "1 - 2. SERVICE MENU 2".
6 ) Set the MODEL NAME depending on the destination.
3Refer to page 4 - 8  "6 - 2. MODEL NAME SETTING FUNCTION".
3Refer to page 4 - 24  "14. MODEL NAME SETTING PROCEDURES".
7 ) Write the information read in the above step 1).
MEMO
n
When the reading cannot be executed, conduct the following operation.
--- Set “0” to USAGE TIME and perform initialization. 
--- Reset the WHITE BALANCE set values.
--- Reset the GAMMA set value.
8 ) Write the serial number.
3Refer to page 4 - 9  "6 - 3. SERIAL NUMBER SETTING FUNCTION".
3Refer to page 4 - 22  "12. SERIAL NUMBER WRITING PROCEDURES".
9 ) Reset the temperature watch setting information.
3Refer to page 4 - 10  "6 - 5. SYSTEM LOG AND TEMPERATURE LOG INITIALIZATION".
3Refer to page 4 - 25  "15. TEMPERATURE MONITOR SETTING PROCEDURES".
1 - 3. LCD MODULE REPLACEMENT PROCEDURES
1 ) Set “0” to USAGE TIME and perform initialization. 
2 ) Reset the WHITE BALANCE set values. 
3 ) Reset the GAMMA set value.
4 ) Reset the temperature watch setting information.
3Refer to page 4 - 10  "6 - 5. SYSTEM LOG AND TEMPERATURE LOG INITIALIZATION".
3Refer to page 4 - 25  "15. TEMPERATURE MONITOR SETTING PROCEDURES".
CHAPTER 3. IMPORTANT INFORMATION FOR SERVICING THE DISPLAY
PN-L702B IMPORTANT INFORMATION FOR SERVICING THE DISPLAY
 3 – 3
1 - 4. MAJOR PARTS REPLACEMENT PROCEDURES
When any one of below parts is replaced, perform the FACTORY RESET and set as shown in the table below.
■ MAIN PWB
■ EXPANSION BOARD
*
1
Both main firmware and LAN microcontroller firmware need to be updated to the latest version.
3Refer to page 5 - 1  "1. MAIN FIRMWARE UPDATE PROCEDURE".
3Refer to page 5 - 4  "2. LAN MICROCONTROLLER FIRMWARE UPDATING PROCEDURES (PN-ZB01)".
*
2
3Refer to page 4 - 3  "3. CALIBRATION".
*
3
3Refer to page 4 - 13  "8. WHITE BALANCE SETTING PROCEDURES BY OSD".
*
4
It needs to be updated to the latest version.
3Refer to page 5 - 9  "4. EDID WRITING PROCEDURES".
*
5
3Refer to page 4 - 1  "1. OPERATING PROCEDURES".
3Refer to page 4 - 9  "6 - 3. SERIAL NUMBER SETTING FUNCTION".
3Refer to page 4 - 22  "12. SERIAL NUMBER WRITING PROCEDURES".
3Refer to page 4 - 8  "6 - 2. MODEL NAME SETTING FUNCTION".
3Refer to page 4 - 24  "14. MODEL NAME SETTING PROCEDURES".
*
6
3Refer to page 4 - 9  "6 - 4. USAGE TIME SETTING FUNCTION".
3Refer to page 4 - 23  "13. USAGE TIME SETTING PROCEDURE".
*
7
3Refer to page 4 - 18  "10. GAMMA SETTING PROCEDURES WITH THE OSD".
1 - 5. WORK PROCEDURES FOR REPLACING THE TOUCH PANEL
1 ) Check the version of firmware for the Touch Panel.
3Refer to page 5 - 6  "3. TOUCH PANEL FIRMWARE UPDATE PROCEDURE".
2 ) Check the amount of light using the LED Sensor Failure Diagnostic Tool.
3Refer to page 4 - 40  "20. LED SENSOR FAILURE DIAGNOSTIC TOOL".
3 ) Check the performance of the touch pen.  (drawing, reaction of buttons)
Reference
Parts name
Parts function
OPERATION
Firmware 
update
*1
Calibration 
setting
*2
WHITE 
BALANCE 
setting
*3
GAMMA 
setting
*7
EDID 
writing
*4
Model 
name, 
serial 
number 
setting
*5
USAGE 
TIME 
setting
*6
IC300
STDP8028-AB 
(MARS)
Microcontroller-
equipped scaler IC
F
IC304
R1EX24002AS
AS0A
I
2
C compliant 
EEPROM 
(Stores EDID data 
for D-SUB.)
F
IC401
R1EX24002AS
AS0A
I
2
C compliant 
EEPROM 
(Stores EDID data 
for HDMI.)
F
IC1007
R1EX24128AS
AS0A
I
2
C compliant 
EEPROM 
(Stores settings 
data.)
F
F
F
F
F
IC1004
SST25VF032B
-66-4I-S2AF-T
Serial flash memory 
(Stores program.)
F
Reference
Parts name
Parts function
OPERATION
Firmware 
update
*1
Calibration 
setting
*2
WHITE 
BALANCE 
setting
*3
EDID 
writing
*4
Model name, 
serial number 
setting
*5
USAGE 
TIME 
setting
*6
IC204
R1EX24002
ASAS0A
I
2
C compliant EEPROM 
(Stores EDID data for DVI.)
F
PN-L702B SERVICE MENU/VARIOUS SETTING TOOL OPERATING PROCEDURES
 4 – 1
CHAPTER 4.  SERVICE MENU/VARIOUS SETTING TOOL OPER-
ATING PROCEDURES
1. OPERATING PROCEDURES
1 - 1. SERVICE MENU 1
Used to display the model name, the manufacturing No., the firmware
version/checksum, and the usage time.
1 ) Press the [SIZE] button of the remote control for about 5 seconds
(the LED blinks, and the “F” mark is displayed in the upper left cor-
ner of screen.), press the [BRIGHT- ( 
1 )], [VOL- ( 4 )], [BRIGHT+
3 )] and [VOL+ ( 2 )] button in sequence.
MEMO
n
Immediately after turning on the power, “CALCULATING” is dis-
played for the checksum for a while, and the result is dipslayed.
n
“F” mark is displayed in red when the adjustment lock is set to
other than “Not” and displayed in blue when the OSD display is
set to “Not.” For the other cases, it is displayed in green. (The red
color of “F” mark takes priority.)
MODEL
Model name
S/N
Serial number
FIRM VERSION 
(MAIN)
Main firmware version
When the combination with the sub firm-
ware is not proper, “NG” is displayed.
CHECK SUM(MAIN)
Main firmware check sum
FIRM VERSION 
(SUB)
Sub firmware version
When combination with the main firmware 
is not proper, “NG” is displayed.
CHECK SUM(SUB)
Sub firmware check sum
USAGE TIME
Usage time
ADJUSTMENT 
CHECK
When the white balance setting is reset to 
the initial value after replacement of the 
PWB or the panel, “W/BW” is displayed. 
When the calibration setting value is reset 
to the initial value, “CALIB” is displayed. 
(Normally it is not displayed.)
LVDS CABLE 
CHECK
When the cable between the I/F PWB and 
the liquid crystal module is not connected 
properly, it is displayed. 
(Normally it is not displayed.)
SERVICE1
SERVICE2
SERVICE3
MODEL
S/N
SERVICE MENU1
FIRM VERSION (MAIN)
CHECK SUM (MAIN) 
FIRM VERSION (SUB)
CHECK SUM (SUB)
USAGE TIME
1/1
: PN-XXXX
: XXXXXXXX
: OK Ver 1.00 (110801)
: OK 1234ABCDEF
: OK Ver 1.00 (110801)
: OK 1234ABCD
: 999999H
END
̖[MENU]
ADJUSTMENT CHECK
: W/B CALIB
Only when the expansion board is equipped.
Only when the whitebalance
adjustment, calibration
adjustment, and is not excuted.