(2) When the back-up master recovers from a breakdown — Recovery
declaration at the master
 1) The recovery declaration operation is done at the master.
 2) Each satellite stops sending updated GLU/PBLU data to the master temporarily.
 3) The master sends the updated GLU/PBLU data files to the back-up master.
 4) The master informs all satellites of the back-up master’s recovery.
 5) The satellites restart sending updated GLU/PBLU data to the back-up master.
Flow of a recovery declaration at the master
The recovery declaration procedure is the same as “(1) When the master recovers from a
breakdown.”
2) Transmission stops 
     temporarily.
3) Updated data file
Satellite
4) Back-up master 
      recovery information
Back-up master
Master
 1) Recovery declaration
5) Restart of updated data transmission
(Processing)
56
Error Recovery
1. Manual clear operation
With the manual clear operation, you can clear various item memories when necessary. This
operation should be done only when the master or system breaks down.
(1) Manual clearing of the clerk sign-on state — master
You can clear the clerk sign-on state in case of trouble.
This operation is effective only for the sign-on flag for clerks who are signed on at the
master.
Clearing procedure
1.
Select “PGM2 MODE” from the mode selection
window and touch the 
ENTER
 key.
2.
Select “DATA CLEAR” and touch the 
ENTER
 key.
3.
Select “SIGN ON FLAG” and touch the 
ENTER
 key.
NOTE
Clerk sales data for each satellite at which a clerk has signed on is not collected by manual
clearing of the sign-on state. Clerk sales data is collected only when sign-off operation is done
correctly at satellites.
5
57
(2) Manual clearing of the GLU/PBLU data in use — master
You can clear the GLU/PBLU data in use in the event of some trouble.
This operation clears all GLU/PBLU data that is currently in use.
Clearing procedure
After selecting “DATA CLEAR” from the PGM2 MODE menu with the same procedure as
steps 1 and 2 in “(1) Manual clearing of the sign-on state,” select “GLU USED FLAG.”
(3) Manual clearing of the drive-through data in use — master
You can clear the drive-through data in use in the event of some trouble.
This operation clears all drive-through data that is currently in use.
Clearing procedure
After selecting “DATA CLEAR” from the PGM2 MODE menu with the same procedure as
steps 1 and 2 in “(1) Manual clearing of the sign-on state,” select “D-THRU USED FLAG.”
(4) Manual clearing of the transaction memory — master and satellite
You can clear the transaction memory in the event of some trouble.
This function is available at the master and satellites.
Clearing procedure
After selecting “DATA CLEAR” from the PGM2 MODE menu with the same procedure as
steps 1 and 2 in “(1) Manual clearing of the sign-on sate,” select “TRANSACTION.”
(5) Manual clearing of the hourly sales data memory — master and satellite
You can clear the hourly sales data memory in the event of some trouble. This function is
available at the master and satellites.
Clearing procedure
After selecting “DATA CLEAR” from the PGM2 MODE menu with the same procedure as
steps 1 and 2 in “(1) Manual clearing of the sign-on state,” select “HOURLY.”
(6) Manual clearing of the clerk sales data memory — master and satellite
You can clear the clerk sales data memory in the event of some trouble. This function is
available at the master and satellites.
Clearing procedure
After selecting “DATA CLEAR” from the PGM2 MODE menu with the same procedure as
steps 1 and 2 in “(1) Manual clearing of the sign-on state,” select “CLERK.”
58
(7) Manual clearing of the daily net sales data memory — master and
satellite
You can clear the daily net sales data memory in the event of some trouble. This function is
available at the master and satellites.
Clearing procedure
After selecting “DATA CLEAR” from the PGM2 MODE menu with the same procedure as
steps 1 and 2 in “(1) Manual clearing of the sign-on state,” select “DAILY NET.”
(8) Manual clearing of the T-LOG buffer — master and satellite
You can clear the T-LOG buffer in the event of some trouble. This function is available at
the master and satellites.
Clearing procedure
After selecting “DATA CLEAR” from the PGM2 MODE menu with the same procedure as
steps 1 and 2 in “(1) Manual clearing of the sign-on state,” select “T-LOG.”
(9) Manual clearing of the electronic journal data — master and satellite
You can clear the electronic journal data in the event of some trouble. This function is
available at the master and satellites.
Clearing procedure
After selecting “DATA CLEAR” from the PGM2 MODE menu with the same procedure as
steps 1 and 2 in “(1) Manual clearing of the sign-on state,” select “E.JOURNAL.”
NOTE
For T-LOG polling, see page 18.
The above-mentioned manual clearing jobs should be performed at the advice of your
authorized SHARP dealer.
Page of 74
Display

Click on the first or last page to see other UP-3300 (serv.man20) service manuals if exist.