12
Clerk Keys
This POS terminal allows the operator to use the following four clerk identification systems:
•  Real clerk keys (standard 6 clerks/max. 126 clerks)
•  Clerk code entry (max. 255 clerks)
•  Clerk entry keys (max. 10 clerks)
•  WMF clerk keys (max. 127 clerks)
The standard POS terminal has been shipped with the real clerk key system being programmed. If you want
to change the clerk identification system, contact your authorized SHARP dealer.
Real clerk keys (1, 2, 3, 4, 5, and 6)
These keys serve to identify clerks. Put one of the 1 through 6 keys in the clerk switch.
Clerk code entry (1 through 9999)
Enter the clerk code by using the following procedure:
Clerk entry keys
These keys identify clerks. Press any one of these keys.
WMF clerk keys
Put one of the WMF clerk keys in the WMF clerk switch.
CLK
1
CLK
10
XXXX
Clerk code
˚
13
Display
This POS terminal is provided with an LCD operator display.
Operator display
The display can be tilted to the best viewing angle.
Do not try to force the display beyond its full opened position.
• Screen example 1 (REG mode)
Price level shift indicator (P1-P7)
Shows the PLU price level currently selected (reversing
display at the happy hour).
PLU level shift indicator (L01-L10)
Shows the PLU level currently selected.
Receipt shift indicator (r)
Shows the receipt shift status.
T-Log near full indicator ( )
Appears ( ) when the used memory is 80%.
Appears ( ) when the used memory is 90%.
Appears ( ) when the used memory is 95%.
Stock alarm indicator ( 
)
Appears when the stock of the PLU which you entered is
zero or negative.
Department shift status indicator (D1-D4)
Shows the department shift status currently selected.
NOTE
Window: In the REG mode, the window shows sales information you have just entered such as
items and media types.
Received media type 
Numeric entry: Entered figures appear at the cursor position.
Sales amount including taxes
Mode name
Clerk code
Time
14
• Screen example 2 (PGM mode)
Screen save mode
When you want to save the electric power or save the display’s life, use the screen save function. This function
can turn the LCD backlight off when any server does not operate the POS terminal for an extended period of
time. You can program the time for which your POS terminal should keep the normal status (in which the
backlight is “ON”) before it goes into the screen save mode.
To go back to the normal mode, press any key.
Window
In the PGM mode, 
programmable items are listed.
Double-size character mode indicator (W):
Appears when the double-size character 
mode is selected during text programming.
Caps lock indicator (A/a): 
The upper-case letter “A” appears when
Caps Lock is on, and the lower-case
letter “a” appears when Caps Lock is off
during text programming.
Clerk code
Mode name
Time
VAT shift status indicator (V)
Appears when the VAT status is shifted.
Electronic mail indicator (M)
Appears when an electronic mail is received.
Electronic journal near full indicator ( )
Appears ( ) when the used memory is 80%.
Appears ( ) when the used memory is 90%.
Appears ( ) when the used memory is 95%.
Receipt ON/OFF status indicator (R)
Appears when the receipt ON-OFF function signs OFF.
Sentinel mark (X)
Appears in the lower right corner of the screen when the
cash in drawer exceeds a programmed sentinel amount.
The sentinel check is performed for the total cash in drawer.
Before Operating the POS
Terminal
This chapter describes those steps required to take when you use the POS terminal for the first time.
Display Adjustment
You can adjust the brightness and contrast of the display by using the corresponding controls.
Connecting the Printer and Installing the Paper Rolls
Before using the POS terminal, connect a printer and install paper rolls. For those operations, see the
printer’s manual.
The ER-A770 may be configured with multiple types of printers offered in the market. For specific
instructions related to the handling and care of the printer, please refer to the applicable printer instruction
manual.
• Brightness control
Turning the control backwards
darkens the display and turning it
forwards brightens the display.
• Contrast control
Turning the control backwards
darkens the display and turning it
forwards lightens the display.
2
The backlight in the display is a consumable part.
When the LCD display may no longer be adjusted and becomes darker, you should change the backlight.
Consult your authorized SHARP dealer for further details.
15