51
Part
3
 FOR THE  MANAGER
Part
2
Part
1
Programming for 
V
1. Specify the key to program.
2. Text programming (Press 
s
to skip. / Press 
A
to terminate.)
3. Rate programming (Press 
s
to skip. / Press 
A
to terminate.)
4. Open rate entry programming (Press 
s
to skip. / Press 
A
to terminate.)
PRESET RATE     
   PRESET ENABLE
s
(2) Press the 
s
key to register the setting.
Immediately after displaying guidance message for
the next step, the current setting for the next step
will be displayed.
(1) Go to (2) when the open rate entry does not need to
be changed from "OPEN ENABLE".  Otherwise,
press 
:
key to display "OPEN DISABLE".
Each time 
:
key is pressed, the display shows
"OPEN DISABLE" and "OPEN ENABLE" alternatively.
Default setting is "ENABLE".
OPEN RATE ENTRY 
     OPEN ENABLE
s
(2) Press the 
s
key to register the rate.
Immediately after displaying guidance message for
the next step, the current setting for the next step
will be displayed.
        0.939938
0.939938
(1) Enter the rate using numeric keys, using a decimal
point when setting fractional rates.
The rate can be set from 0.000000 to 999.999999.
Default setting is 0.000000.
ENTER EX RATE   
        0.000000
s
(3) Press the 
s
key to register the text.
Immediately after displaying guidance message for
the next step, the current setting for the next step
will be displayed.
EX              
EX
(2) Enter the text.
A maximum of 16 characters can be entered.
Please refer to "Guidance for text programming" on
page 13 for entering the text.
When you start entering a character, the current
text data will be overwritten by new data.
Pressing the 
P
and 
@
key moves the cursor to
the right and left respectively.
ENTER TEXT      
EXCH1           
:
(1) Press 
:
key to enter text programming.
Immediately after displaying guidance message, the
current text data will be displayed.
EXCHANGE PROG.  
ENTER[00]KEY    
V
(1) Press the 
V
key to enter 
V
programming.
Immediately after displaying "EXCHANGE PROG.",
guidance message for the next step will be displayed.
Operator display
Key operation
 A203_3 FOR THE MANAGER(SEEG)  06.5.6 8:08 PM  Page 51
52
5. Preset rate entry programming (Press 
s
to skip. / Press 
A
to terminate.)
6. Position of decimal point programming (Press 
s
to skip. / Press 
A
to terminate.)
7. Terminate programming
Item:
Selection:
Print:
A
Open rate entry
Enable*
0
Disable
1
B
Preset rate entry
Enable*
0
Disable
1
C
TAB (position of decimal point from right)
0-3 (default:2)
Programming for 
r
,
R
,
X
,
Y
,
c
and 
b
The 
X
key is used as an example below.
Programming for 
r
and 
R
, the step 3 and 4 are skipped.
1. Specify the key to program.
CH1 PROGRAMMING 
ENTER[00]KEY    
X
(1) Press the 
X
key to enter 
X
programming.
Immediately after displaying "CH1 PROGRAMMING",
guidance message for the next step will be displayed.
Operator display
Key operation
From left, ABC
Rate
Text
Print
            0.00
A
(1) Press the 
A
key to terminate the 
V
key
programming.
ENTER[TL/NS]KEY 
s
(2) Press the 
s
key to register the setting.
               2
2
(1) Enter the position of decimal point from right using
numeric key.
The position of decimal point from right can be set
from 0 to 3.
Default setting is 2.
TAB             
               2
s
(2) Press the 
s
key to register the setting.
Immediately after displaying guidance message for
the next step, the current setting for the next step
will be displayed.
(1) Go to (2) when the preset rate entry does not need
to be changed from "PRESET ENABLE".
Otherwise, press 
:
key to display "PRESEST
DISABLE".
Each time 
:
key is pressed, the display shows "PRESET
DISABLE" and "PRESET ENABLE" alternatively.
Default setting is "ENABLE".
 A203_3 FOR THE MANAGER(SEEG)  06.5.6 8:08 PM  Page 52
53
Part
3
 FOR THE  MANAGER
Part
2
Part
1
2. Text programming (Press 
s
to skip. / Press 
A
to terminate.)
3. Footer print on receipt programming (Press 
s
to skip. / Press 
A
to terminate.)
4. Entry of amount tendered programming (Press 
s
to skip. / Press 
A
to terminate.)
LIMIT DIGITS    
               8
s
(2) Press the 
s
key to register the setting.
Immediately after displaying guidance message for
the next step, the current setting for the next step
will be displayed.
(1) Go to (2) when the entry of amount tendered does
not need to be changed from "NON
COMPULSORY".  Otherwise, press 
:
key to
display "COMPULSORY".
Each time 
:
key is pressed, the display shows
"COMPULSORY" and "NON COMPULSORY"
alternatively.  In case of 
c
and 
b
programming,
"INHIBIT" is displayed instead of "NON
COMPULSORY".
Default setting is "NON COMPULSORY" or "INHIBIT".
AMOUNT TENDERED 
  NON COMPULSORY
s
(2) Press the 
s
key to register the setting.
Immediately after displaying guidance message for
the next step, the current setting for the next step
will be displayed.
(1) Go to (2) when the footer print on receipt does not
need to be changed from "NO".  Otherwise, press
:
key to display "YES".
Each time 
:
key is pressed, the display shows
"YES" and "NO" alternatively.
Default setting is "NO".
This programming decides whether or not the
machine should print a message at the foot of a
receipt when a specified key is used.  With regard
to programming method of footer logo message,
refer to "Logo messages" section on page 23.
FOOTER PRINT    
              NO
s
(3) Press the 
s
key to register the text.
Immediately after displaying guidance message for
the next step, the current setting for the next step
will be displayed.
CHEQUE          
CHEQUE
(2) Enter the text.
A maximum of 16 characters can be entered.
Please refer to "Guidance for text programming" on
page 13 for entering the text.
When you start entering a character, the current
text data will be overwritten by new data.
Pressing the 
P
and 
@
key moves the cursor to
the right and left respectively.
ENTER TEXT      
CHECK1          
:
(1) Press 
:
key to enter text programming.
Immediately after displaying guidance message, the
current text data will be displayed.
 A203_3 FOR THE MANAGER(SEEG)  06.5.6 8:08 PM  Page 53
54
5. Entry digit limit programming (Press 
s
to skip. / Press 
A
to terminate.)
6. Terminate programming
Item:
Selection:
Print:
A
Footer print
No*
0
Yes
1
B
Amount tendered entry
Non compulsory (for 
X
and 
Y
)*
0
Inhibit (for 
c
and 
b
)*
0
Compulsory 1
C
Entry digit limit
0-8 (default:8)
Function parameters for 
A
*1:Item:
Selection:
Entry:
A
Footer printing*
Allow
1
Disallow*
0
B
Amount tendered entry*
Compulsory
1
Non-compulsory*
0
C
Entry digit limit
0-8 (default:8)
*
1
ABC 
A
To program   0  for all items
To program for another key
@
s
From left, ABC
Text
Print
            0.00
A
(1) Press the 
A
key to terminate the 
X
key
programming.
CH2 PROGRAMMING 
ENTER[00]KEY    
s
(2) Press the 
s
key to register the setting.
In the case of programming for the 
X
and 
c
keys, the display shows "CH2 PROGRAMMING"
and "CR2 PROGRAMMING" respectively.  Go to
step 2 to program the 
Y
and 
b
keys.
In the case of programming for the 
r
R
Y
and 
b
keys, the display shows
"ENTER[TL/NS]KEY".  Go to step 6.
               7
7
(1) Enter entry digit limit using numeric key.
The entry digit limit can be set up to 8.
Default setting is 8.
The entry digit limit is in effect for REG mode
operation but can be overridden in the MGR mode.
The entry digit limit is represented by the number of
allowable digits for the maximum entry or total
amount.  When "0" is set, the operation of the
corresponding key is prohibited.
 A203_3 FOR THE MANAGER(SEEG)  06.5.6 8:08 PM  Page 54
Page of 93
Display

Click on the first or last page to see other XE-A203 (serv.man7) service manuals if exist.