DOWNLOAD Sharp XE-A201 (serv.man8) Service Manual ↓ Size: 1.29 MB | Pages: 71 in PDF or view online for FREE

Model
XE-A201 (serv.man8)
Pages
71
Size
1.29 MB
Type
PDF
Document
User Manual / Operation Manual
Brand
Device
ECR / Operation Manual (UK Only Version)
File
xe-a201-sm8.pdf
Date

Sharp XE-A201 (serv.man8) User Manual / Operation Manual ▷ View online

27
Item:
Selection:
Entry:
A
VAT 4 or tax 4 status
Taxable
1
Non-taxable*
0
B
VAT 3 or tax 3 status
Taxable
1
Non-taxable*
0
C
VAT 2 or tax 2 status
Taxable
1
Non-taxable*
0
D
VAT 1 or tax 1 status
Taxable*
1
Non-taxable
0
E
SICS / Normal
SICS
1
Normal*
0
F
Sign
Negative department
1
Positive department*
0
G
Entry digit limit
0-8 (default:8)
H
Type of unit price entry
Open and preset
3
Preset only
2
Open only*
1
Inhibit department key
0
VAT/tax status (taxable 1 through 4 / non-taxable)
• When any entry of a taxable department is made in a transaction, tax is automatically computed according to
the associated tax rate as soon as the transaction is completed.
SICS (Single Item Cash Sale)
• If an entry of a department programmed for SICS is made first, the sale will be finalized as a cash sale as
soon as the department key is pressed.  If the entry is made after entering a department not programmed for
SICS, the sale will not be finalized until the 
A
key is pressed.
Entry digit limit
• Set the number of allowable digits for the maximum entry amount for each department.  The limit is effective
for operations in the REG mode and can be overridden in the MGR mode.
Preset unit price
To program another department, start from the beginning without pressing the 
A
key.
For department 33-50:
d
s
Dept. code
Unit price
(max. six digits)
A
To program zero
To program zero
Dept. key
Unit price
(max. six digits)
D
*
*To program departments 17 through 32, press the department shift key.
A
Tax status
From left, EGH
Sign(F)
ABCDEFGH
00011183 
@
"
 
A
Print
Key operation example
 A201_3 FOR THE MANAGER  01.11.11 10:22 AM  Page 27
28
If a department is not programmed to allow the entry of preset unit prices in functional
programming, the department is automatically changed to allow the entry of preset unit prices by
this programming entry.
The PLU function allows speedy key entries whereby a price is automatically called up when a code is entered.
The subdepartment is a kind of “open PLU”, which requires you to enter a price after the PLU code is entered.
By default, PLU/subdepartment setting for 1 through 200 codes are possible, and can extend to 1200.  To
extend the number, please refer to “EJ memory type” on page 40.
Unit price and associated department assignment
*2: For a subdepartment, set the limit amount of unit price entry.
To program the following PLU code, start from entering a unit price or an associated department code without
pressing the 
A
key.
To program another PLU code, start from the beginning without pressing the 
A
key.
To delete a PLU code, use the following sequence:
PLU code
p
v
To delete the following PLU code
To delete another PLU code
A
PLU code
Unit price
Associated dept.
p
125 
#
A
Print
Key operation example
PLU (Price Look-Up) and Subdepartment Programming
2
Unit price
1000 
!
A
Print
Key operation example
PLU code
*1: To assign departments 17 through 32, press the department shift key.
p
To program zero
Unit price
(max. six digits)
A
D
*
1
Associated 
Dept. key
*
2
PLU code
When the associated department is department 33-50:
p
d
s
To program zero
Associated
dept. code
(33 to 50)
Unit price
(max. six digits)
A
*
2
 A201_3 FOR THE MANAGER  01.11.11 10:22 AM  Page 28
29
PLU/subdepartment selection
*: 0 for subdepartment or 1 for PLU
When you program the last PLU code, the programming sequence will be complete with a press of
the 
s
key.
The cash register provides miscellaneous keys such as 
%
&
-
f
r
R
V
C
c
b
and
A
.
Rate for 
%
&
and 
V
*:  Rate
0.00 — 100.00 (% rate)
0.000000 — 999.999999 (Currency exchange rate)
You must use a decimal point when setting fractional rates.
Percent rate
Currency 
exchange rate
10 
P
25
%
P
95583
V
A
Print
Key operation example
*Rate
or
%
V
A
&
To program another rate
To program zero
Miscellaneous Key Programming
3
PLU/subdept. 
p
s A
Print
Key operation example
PLU code
p
To program "0"
To program the following PLU code
To program another PLU code
A
s
* A
 A201_3 FOR THE MANAGER  01.11.11 10:22 AM  Page 29
30
Amount for 
-
Percent rate limitation for 
%
and 
&
You can program the upper limit of percent rates for percent entries.
• Percent entries that exceed the upper limit may be overridden in the MGR mode.
• 10.00% can be entered as
10
or  
10P00
.  The 
P
key is needed only
for fractional entry.
Percentage limit
s
29
@
15
P
00
%
A
Print
Key operation example
s
@
29
Percentage limit (0.00 -100.00%)
A
To program zero
To program for another percent key
or
% &
Discount amount
200
-
A
Print
Key operation example
Discount amount (max. six digits)
A
-
To program zero
 A201_3 FOR THE MANAGER  01.11.11 10:22 AM  Page 30
Page of 71
Display

Click on the first or last page to see other XE-A201 (serv.man8) service manuals if exist.