UP-800F/810F (V)
DIAGNOSTICS SPECIFICATIONS
4 – 8
ii. Setting master machine.
On the menu screen, select DATA Trans. (MA). The screen
looks like this:
Enter the terminal No. of the machine you want to test (a 2-digit
number from 1-64)+ Enter. The screen looks like this:
Enter the terminal No. (a 2-digit number from 1-64) of the satel-
lite machine which is to be connected to the test machine +
Enter. The screen looks like this:
When performing the test with multiple satellite machines, type
their terminal numbers (2-digit numbers within the range from
1~64) and press Enter. In addition, you specify the satellite
machines using the area specification function without typing ter-
minal numbers. This is achieved by typing the first terminal num-
ber (2 digits) and the last terminal number (2 digits) of the
satellite machines and then press Enter. For example, if you
want to specify the terminal numbers of satellite machines from
5 to 15, type "0515" for T-No. and press Enter. When executing,
press the Enter key only without typing the terminal numbers.
The display appears like this:
The terminal Nos. of the master machine and the satellite
machines must not duplicate. 
When the terminal No. is specified by using the range specifica-
tion function, the terminal No. of the master machine is excluded
from the range of the terminal No. of the satellite machines. With
above setting, data transmission between the master machine
and the satellite machines is started.
2 Checking
i. The master machine sends data of the following format consist-
ing of 2-byte sequence No. and 254-byte AAH data to the
satellite machine. The master machine displays the sequence
Nos.
Test data format (1 packet: 256 bytes)
XXXX : Sequence No. 2 bytes (4-digit binary coded decimal
number)
AA : Transfer (AAH) 
×
 254 bytes
ii. The satellite machine returns the data it has received, to the
master machine as it is. The satellite machine displays the
sequence No. on the screen.
iii. The master machine receives the data and then checks the
sequence Nos. and 254-byte AAH data. If an error occurs, the
master machine displays an error code and ends the test. If
there are multiple satellite machines, steps i and ii are repeated.
The master machine advances the sequence No. when data is
transferred successfully between it and the satellite machines.
Steps i - iii are repeated.
3 Error display
The following error codes are used (same as for TCP/IP HANDLER)
4 How to exit the program
Press the CANCEL key to exit the program.
INPUT MA T-NO. :
DATA Trans.(MA)
Enter a number
within a range
from 1~64.
INPUT MA T-NO. :  XX
DATA Trans.(MA)
INPUT SA T-NO. :
The terminal No. you
entered is displayed.
INPUT MA T-NO. :  XX
DATA Trans.(MA)
INPUT SA T-NO. :
The terminal No. you
entered is displayed.
&#6#6TCPU /#
+0276/#601㧦::
+02765#601㧦::
 :::::::::::: QT::::
&#6#5'301㧦
Entered T-No. of 
MA is displayed.  
Entered T-No, of 
SA is displayed.
When two or more 
SA T-Nos. are entered, 
all of them are displayed.
01 Command error (excluding the time when data is sent)
02 No data received
03 Received data size present
Received data left
04 Receiving station not ready for receiving (when sending)
“NRDY” is returned because the receiving station is not
ready for receiving.
05 Receiving buffer full (when sending)
The receiving side’s controller receive buffer is full.
06 Resend error (When sending)
The number of retries exceeds the setting (5 times) when
no response is obtained.
07 Collision error (When sending)
When a collision occurs during data transmission, retry over (16
times) at re-collision after random time (0 - 255ms).
08 Line busy time out
Data cannot be sent due to multiple stations communicating
09 Receiving data size over (when receiving)
Insufficient size of receiving buffer.
0A Hardware error
Interface error (No SRN interface or defective SRN controller)
XX
XX
AA
AA
AA
AA
AA
AA
1
2
3
4
5
254 255 256 byte
&#6#6TCPU /#
+0276/#601㧦::
+02765#601㧦::
::::::::::::
:::::::::::: QT::::
&#6#5'301 㧦
6%2+2'4414 㧦 ::
The error code is displayed. 
UP-800F/810F (V)
DIAGNOSTICS SPECIFICATIONS
4 – 9
3-10. MAGNETIC CARD READER DIAGNOSTICS
The program performs the read test of an optional UP-E13MR3.
The test program reads a magnet card of the ISO7811standard and
prints data on the journal.
Press the CANCEL key to return the screen to submenu.
1 Checking
The program reads tracks 1 - 3 of a magnet card of the ISO7811
standard and prints data with the ASCII codes.
2 Display
Data read by the MCR is printed in the areas XXXXX. If an error
occurs, the following error codes are displayed. 
3 How to exit the program.
Press the CANCEL key to exit the program.
3-11. DRAWER DIAGNOSTICS
This diagnostics program is used to perform the drawer open test and
the sensor test. 
(1) Drawer 1 Check
1 Checking
The program turns on the drawer 1 solenoid, senses the value of
the drawer open sensor every 100 ms, and displays the operating
status.
2 Display
3 How to exit the program
Press the CANCEL key to exit the program.
(2) Drawer 2 Check
1 Checking
The program turns on the drawer 2 solenoid, senses the value of
the drawer 2open sensor every 100 ms, and displays the operating
status. The procedure for displaying the menu and exiting the pro-
gram are the same as for the drawer 1 check.
3-12. PRINTER DIAGNOSTICS
This diagnostics program is used to test the built-in printer. 
(1) UP-810 Printer Diagnostics
Execute the diagnostics described on the UP-810 printer diagnostics
manual attached to the end of this document. 
During the diagnostics, only “RINTER DIAG” is displayed on the screen.
For the execution content, the termination conditions, etc., refer to the
printer diagnostics manual. After completion of the diagnostics, the
screen returns to the diagnostics menu. 
(2) UP-820 Printer Diagnostics
Execute the diagnostics described on the UP-820 printer diagnostics
manual attached to the end of this document. 
During the diagnostics, only “RINTER DIAG” is displayed on the screen.
For the execution content, the termination conditions, etc., refer to the
printer diagnostics manual. After completion of the diagnostics, the
screen returns to the diagnostics menu.
3-13. EFT DIAGNOSTICS
This diagnostics program is used to check the EFT (UP-104EF).
Connect the loopback cable to CH4. 
Select EFT Diagnostics on the menu, and turn OFF the power. 
(1) EFT Check
Set all DIPSW1 on the UP-104EF to OFF and turn ON the power of the
machine. The EFT check is automatically performed. 
1 Check content
i The loopback test of ER-DR, ER-CI, and RS-CS is performed for
the RS232C connector. 
ii SWITCH1-8 of DIPSW1 is turned ON one by one to perform the
test. 
iii When the test is completed normally, the sum check of the EFT
ROM is performed andv the write/read check of the RAM is per-
formed. 
2 Display (Normal completion)
3 Display (Abnormal completion)
4 Termination method
When the panel or any key is pressed, the operation is terminated. 
Open Sensor : OPEN  (or CLOSE)
DRAWER 1 Check
EFT Diagnostics
UP-800F/810F (V)
DIAGNOSTICS SPECIFICATIONS
4 – 10
3-14. KEY DIAGNOSTICS 
This diagnostics program is used to test the key codes of the UP-800
keyboard. 
(1) Key code check
1 Check content
The code of pressed key on the keyboard is displayed. 
2 Termination method
When the panel is pressed, the operation is terminated. 
(2) Key code sum check
1 Check content
The code of pressed key on the keyboard is displayed. When the
total of the key codes before pressing Total key is the same as the
key sum value, “PASS!” is displayed. If not, “ERROR!” is displayed.
2 Termination method
Press any key again after displaying PASS or ERROR, and the
operation is terminated.
3-15. SD CARD DIAGNOSTICS
This diagnostics program is used to test the SD card.
(1) SD Card Test 1
1 Check content
The AD card is detected and the write protect status is displayed. In
addition, the SD card register value is displayed. 
2 Termination method
When the panel or any key is pressed after displaying the check
result, the operation is terminated. 
(2) SD Card Test 2
1 Check content
i. The read/write test of the SD card is performed in the following
procedures.
ii. Create a file named “SD_TEST.SDA” in the SD card, and write
the logo data in the RAM into the SD card. In this case, if there is
a file of the same name, overwrite it. 
iii. After completion of writing, read the written data from the SD
card. 
iv. Verify the read data and the logo data in the RAM. If they do not
match, “Error” is displayed and the test is automatically termi-
nated. 
v. Repeat the procedures of i - iii.
Error display list
2 Termination method
When the panel or any key is pressed during error display during
the test, the operation is terminated. 
(3) SD Card Test 3
1 Check content
The SAD card is detected, and the write protect status is displayed,
and the read/write test is performed. 
i. The SD card is detected and the write protect status is dis-
played. 
ii. When any key is pressed, the procedures of iii, iv, and v are per-
formed. If no SD card is detected or write protect is detected, the
error print is made and the operation is terminated. 
iii. Create a file named “SD_TEST.SDA” in the SD card, and write
the logo data in the RAM of the machine into the SD card. In this
case, if there is a file of the same name, overwrite it. 
iv. After completion of writing, read the written data from the SD
card. 
v. Verify the read data and the logo data in the RAM. According to
the result, “PASS!” or “ERROR!” is displayed and the operation is
terminated. The error display is the same as the SD Card Test 2. 
*The register ID of the SD card is not displayed. 
2 Termination method
When the panel or any key is pressed after displaying the check
result, the operation is terminate
Error display
Error content
SD NO CONNECT
SD card not detected
SD WRITE PROTECT
SD card write protect
SD READ ERROR
SD read error
SD WRITE ERROR
SD write error
SD DATA VERIFY ERROR
Data verify error
UP-800F/810F (V)
HARDWARE DESCRIPTION
5 – 1
CHAPTER 5. HARDWARE DESCRIPTION
1. BLOCK DIAGRAM
CPU  clock
㧦 200MHz
 
Bus clock
㧦 33MHz
 
Peripheral clock
㧦 16.6667MHz
Bus endian setting 㧦 Little endian
Controller
Synchronization type serial
Synchronization type 
serial
Synchronization type serial
Synchronization type serial
Async type serial
Bus connect
Rear display
Interface
Contactless clerk 
Contactless clerk key 
Ethernet Controller
etc.
Key
Page of 86
Display

Click on the first or last page to see other UP-800 (serv.man25) service manuals if exist.