DOWNLOAD Sharp ER-A490 (serv.man4) Service Manual ↓ Size: 375.67 KB | Pages: 35 in PDF or view online for FREE

Model
ER-A490 (serv.man4)
Pages
35
Size
375.67 KB
Type
PDF
Document
Service Manual
Brand
Device
ECR / ERA490 Option Service Manual
File
er-a490-sm4.pdf
Date

Sharp ER-A490 (serv.man4) Service Manual ▷ View online

2.  Connection between the terminal and
MODEM
SD : TRANSMITTED DATA
RD : RECEIVED DATA
DTR : DATA TERMINAL READY
DSR :  DATA SET READY
RTS :  REQUEST TO SEND
DCD:  DATA CARRIER DETECTOR
CTS :  CLEAR TO SEND
CI
: CALLING INDICATOR
FG : FRAME GROUND
3.  Connection between the ECR and
Kitchen printer: ER-02RP
Wiring diagram
[Kitchen printer (ER-02RP)]
SD
: TRANSMITTED DATA
RD
: RECEIVED DATA
SG
:  SIGNAL GROUND
PE
: PATER END
FAULT : MOTOR LOCK
BUSY
: BUSY
DCD
:  DATA CARRIER DETECTOR
DSR
:  DATA SET READY
CTS
:  CLEAR TO SEND
FG
: FRAME GROUND
SD
SD
RD
SG
RD
3
2
4
6
7
1
8
5
2
3
20
6
4
8
5
7
RTS
DCD
DTR
DSR
CTS
CI
22
9
SG
RTS
DCD
DTR
DSR
CTS
CI
FG
1
FRAME GROUND is connected
to the shield of the cable.
MODEM
TERMINAL
25PIN D-SUB
9PIN D-SUB
SD
2
DCD
R D
FG
R D
3
20
1
1
2
8
KITCHEN PRINTER: ER-02RP
SG
7
PE
10
FAULT
12
BUSY
3
5
6
ECR
SD
SG
DSR
CTS
25PIN D-SUB
9PIN D-SUB
FRAME GROUND is connected
to the shield of the cable.
1 – 4
4.  Connection between the ECR and Slip
printer: TM-295 (By EPSON)
1. Data transmission format
8bits ASCII code
No start bit
Non parity
One stop bit
Rate: 9600 asynchronous (PGM programming: #6412, #6552)
2. Handshaking
DTR/DSR control
SD : TRANSMITTED DATA
RD : RECEIVED DATA
DTR : DATA TERMINAL READY
DSR :  DATA SET READY
RTS :  REQUEST TO SEND
DCD:  DATA CARRIER DETECTOR
CTS :  CLEAR TO SEND
INIT : PRINTER INITIAL
FG : FRAME GROUND
*
NOTE:
Slip printer:
Set TM-295 DIP switch to ON for use.
 
FG
1
R D
TXD
DTR
SD
2
7
20
2
3
7
8
SLIP
25
INIT
RXD
3
RTS
4
DSR
6
SG
4
5
6
ECR
CTS
ER
GND
DSR
INIT
25PIN D-SUB
9PIN D-SUB
1 – 5
CHAPTER 6. RS-232 PROTOCOL
1. Basic protocol specification
1) Data transmission from the host to a satellite
ACK
EOT
( 1 )  Inquines of the satellite.
( 4 )  Receives ACK.
( 5 )  Sends the text.block.
( 7 )  Resends the text block if NAK is received.
        Resends the text block up to two times.
        Sends EOT and terminates the operation
        with error if NAK is still received after the
        second resending of text block.
( 9 )  Sends the next text if ACK is received and
        sends EOT and terminates the operation if
        data transfer is finaiized.
( 2 )  Receives ENQ.
        Check the terminal No.
        to see if it is its own.
( 3 )  Sends ACK.
( 6 )  Receives text.
        Checks the check sum,text
        data,etc. And goes to (8)
        if there is no error in them.
( 8 )  Sends ACK.
( 10 )  Terminates the operation if EOT
          is received.
ENQ
Host
Satellite
Dummy
(3bytes)
Terminal No.
(6bytes)
Start code
Text (parameter)
End code
Text (FDS)
Text (DATA)
Three types of
text block formats
are available
NCK
ACK
( 8 )'  Sends NAK if any error
         occurs.
1 – 6
2) Data transmission from satellite to the host
ACK
EOT
( 1 )  Inquines of the satellite.
( 4 )  Receives ACK.
( 5 )  Sends the text.block.
( 7 )  Resends the text block if NAK is received.
        Resends the text block up to two times.
        Sends EOT and terminates the operation
        with error if NAK is still received after the
        second resending of text block.
( 9 )  Sends the next text if ACK is received and
        sends EOT and waits for ENQ.
( 2 )  Receives ENQ.
        Checks the terminal No.
        to see if it is its own.
( 3 )  Sends ACK.
( 6 )  Receives text.
        Checks the check sum,text
        data,etc. And goes to (8)
        if there is no error in them.
( 8 )  Sends ACK.
( 10 )  Terminates the operation if EOT
          is received.
ENQ
Host
Satellite
Dummy
(3bytes)
Terminal No.
(6bytes)
Start code
Text (parameter)
End code
Text (DATA)
NAK
ACK
( 8 )'  Sends NAK if any error
         occurs.
ENQ
ACK
Continued on the
next page
1 – 7
Page of 35
Display

Click on the first or last page to see other ER-A490 (serv.man4) service manuals if exist.