DOWNLOAD Sharp ER-A490 (serv.man4) Service Manual ↓ Size: 375.67 KB | Pages: 35 in PDF or view online for FREE

Model
ER-A490 (serv.man4)
Pages
35
Size
375.67 KB
Type
PDF
Document
Service Manual
Brand
Device
ECR / ERA490 Option Service Manual
File
er-a490-sm4.pdf
Date

Sharp ER-A490 (serv.man4) Service Manual ▷ View online

#913-D:
1. Drawer closing compulsory
2. Error mode
3. Key catch sound
1. Drawer closing
compulsory
2. Error mode
3. Key
catch
sound
913-D
Non-compulsory
All lock error
Enable
0
Disable
1
Miss operation
(One shot error)
Enable
2
Disable
3
Compulsory
All lock error
Enable
4
Disable
5
Miss operation
(One shot error)
Enable
6
Disable
7
[JOB#928] MRS = 0104
#928-A:
1. Printing of slip logo text
1. Printing of slip logo text
928-A
No
0
Yes
1
#928-B:
1. VP message printing on slip
2. Header line on slip paper when a reorder is made
printed
1.  VP message
printing on slip
2. Header line on slip
paper when a
reorder is made
printed
928-B 
Check only
Printed
0
Not
1
Check, Credit & Charge
Printed
2
Not
3
#928-C:
1. Printing of PLU on Bill when it is 0
2. Printing of text of a tied PLU in set PLU on Bill
1.  Printing of PLU on
Bill when it is 0
2.  Printing of text of a
tied PLU in set PLU
on Bill
928-C 
Yes
Yes
0
No
2
No
Yes
4
No
6
*
When SRV#928-C is set to 4, in this case the PLU printing on the
slip is depend on the 919-C preset.
#928-D:
1. Printing of PB/NBAL on slip
2. Compulsory Bill print system
1. Printing of
PB/NBAL
on slip
2. Compulsory Bill print system
928-D
Yes
According to each media’s preset
0
Compulsory for every entry
1
Compulsory for PB
2
No
According to each media’s preset
4
Compulsory for every entry
5
Compulsory for PB
6
*
The slip printing at NBAL in GLU system is not compulsory always.
[JOB#929] MRS = 0000
#929-A:
1. The solid line printing under item printing
2. Sorted printing on Bill (Receipt/Slip) when sorted receipt
type
1. The solid line
printing under item
printing
2.  Sorted printing on
Bill (Receipt/Slip)
when sorted receipt
type
929-A 
No
No
0
Yes
2
Yes
No
4
Yes
6
#929-B:
1. Clerk-Z report with open GLU (#181)
1. Clerk-Z report with open GLU (#181)
929-B
Disable
0
Enable
1
#929-C, D: Not used (Fixed at "00")
[JOB#947] MRS = 0000
#947-A: 1. Not used (Fixed at "0")
#947-B: 1. Channel No. for Slip printer = 0 to 7
#947-C, D: Not used (Fixed at "00")
*
When channel No. for online is zero, online system is nothing.
*
Do not select the same channel No. for two or more devices.
*
Use the switches on the I/F board to set the channel No. for the I/F
board connector. (Refer to the RS-232 channel setting in IV.
HARDWARE DESCRIPTION FOR ER-A5RS.)
[JOB#950]
Cleat the "SLIP" key.
Refer to the PROGRAMMING MANUAL for ER-A495G.
2) PGM programming
[JOB#2320]
Media key programming
XXX: Function No.
Functio
n No.
Function
A
B
C
D
E
F
G
H
I
J
K
L
46
CA1
É
F
F
F
F
F
É
É
É
É
F
F
47
CA2
É
F
F
F
F
F
É
É
É
É
F
F
48
CHK
É
F
F
F
F
F
É
É
É
É
F
F
49
CHK2
É
F
F
F
F
F
É
É
É
É
F
F
50
CHK3
É
F
F
F
F
F
É
É
É
É
F
F
51
CHK4
É
F
F
F
F
F
É
É
É
É
F
F
52
CR1
É
F
F
F
F
F
É
É
É
É
F
F
53
CR2
É
F
F
F
F
F
É
É
É
É
F
F
54
CR3
É
F
F
F
F
F
É
É
É
É
F
F
55
CR4
É
F
F
F
F
F
É
É
É
É
F
F
56
CR5
É
F
F
F
F
F
É
É
É
É
F
F
57
CR6
É
F
F
F
F
F
É
É
É
É
F
F
58
CR7
É
F
F
F
F
F
É
É
É
É
F
F
59
CR8
É
F
F
F
F
F
É
É
É
É
F
F
2320
XXX
x
ABCDEFGHIJKL
No change
x
ST
TL
1 – 20
*
Items marked with on (*) are programmable.
A:
EFT function
A
Non compulsory
0
Compulsory
1
B:
Slip print
B
Non compulsory
0
Compulsory
1
C:
Footer print
C
No
0
Yes
1
D:
Non-add code entry
D
Non compulsory
0
Compulsory
1
E:
Change due
E
Enable
0
Disable
1
F:
VP
F
Non compulsory
0
Compulsory
1
  G, H, I, J: Not used (Fixed at "0000")
K:
Drawer opening
K
Yes
0
No
1
L:
Entry of amount tended
L
Non compulsory (Cash, Check)
Inhibit (CR1 to CR8)
0
Compulsory
1
MRS = 000000000000
[JOB#2615]
Programming of the limits to initial slip feed line, No. of times of slip
printing, try ST feed line and No. of times of Validation printing.
XX: Minimum length for bill on receipt = 0 - 30
BB: Initial slip feed line = 0 - 64
CC: Slip print max. line No. = 0 - 99
X
X: No. of times of validation printing = 0 - 9
Y
Y: Feed line after depression of differ ST key = 0 - 9
*
It can be programmed in the SRV mode whether or not to validate
the limits to slip initial feed, the No. of times of slip printing, and the
number of times of validation printing.
MRS = 00009910
[JOB#2616] MRS = 00000000
Programming of the bill printing on slip.
MRS = 00000000
A:
VAT/TAX amount printing on Bill
A
Yes
0
No
1
B:
Taxable amount printing on Bill
B
Yes
0
No
1
C:
Net amount printing on Bill
C
Yes
0
No
1
D:
Printing of time on Bill
D
Yes
0
No
1
E:
Bill printing on slip
E
Yes
0
No
1
F:
Bill printing on receipt
F
Yes
0
No
1
G:
Intermediate reading on slip
G
Yes
0
No
1
H:
Intermediate reading on receipt
H
Yes
0
No
1
[JOB#2995]
Slip printer baud rate programming
A:
Slip printer baud rate (bps)
A
1200
0
2400
1
4800
2
9600
3
MRS = 3
2515
AABBCCXY
x
TL
2616
6
x
ABCDEFGH
0
x
ST
TL
2995
A
0
x
TL
1 – 21
II.  TEST FUNCTION FOR ER-A5RS
CHAPTER 1. General
This test program, is contained in the ER-A49R1 (option control
ROM), has been developed for the purpose of confirming the opera-
tions of the I/F board check conducted by the ER-A5RS mounted in
the ER-A490.
CHAPTER 2. Structure (RS-232 test
& inline test)
1
RS-232 test (RS-232 port test conducted by ER-A5RS
The following structure is required to execute RS-232 test pro-
gram.
ER-A490
ER-A5RS (I/F PWB Unit)
Loopback connector for testing (UKOG-6705 RCZZ)
ER-A49R1 (option control ROM)
Diagram of the loopback connector
CHAPTER 3. Activation
This test program can be activated by inputting 3-digit number 
 TL  with the mode switch in the "SRV" position.
CHAPTER 4. Test Job & Code
1
RS-232 I/F check
JOB & CODE
Contents
500
Channel check
501
RS-232 channel 1 check
502
RS-232 channel 2 check
503
RS-232 channel 3 check
504
RS-232 channel 4 check
505
RS-232 channel 5 check
506
RS-232 channel 6 check
507
RS-232 channel 7 check
CHAPTER 5. Cautions
Options should be installed with the power supply turned off. 
When setting the RS232C channels, avoid setting two or more
ports to the same channel. The ER-A490 allows installation of max.
two units of the ER-A5RS. In this case also, avoid setting two ports
of the ER-A5RS to the same channel. If not, the hardware may be
damaged. 
Concerning the inspection items whose display formats are not
presented in this test function, nothing appears on the display
screen. (blank display)
CHAPTER 6. RS-232 Test
1. Channel check
1
Activation
The program is activated by JOB#500
SRV mode: 500 
 TL 
2
Contents to be tested
Information about connected RS-232 channel is printed.
Printing 
digit
21
20
19
18
17
16
15
3 2 1
CH7 CH6 CH5 CH4 CH3 CH2 CH1
5 0 0
CHn = 0  :  Presence of channel
1  :  Ansence of channel
3
Confirmed content
Printed contents and the setting of channel changeover switch on
PWB are compared and confirmed.
4
Release
The program is terminated after the above contents are printed.
RS-232 channel setting (SW OFF: 1, SW ON: 0)
*
Refer to the silk print on the I/F board.
ER-A5RS CN2
ER-A5RS CN1
SW1
Channel
SW1
Channel
6
5
4
3
2
1
0
0
0
Invalid
0
0
0
Invalid
0
0
1
Channel 1
0
0
1
Channel 1
0
1
0
Channel 2
0
1
0
Channel 2
0
1
1
Channel 3
0
1
1
Channel 3
1
0
0
Channel 4
1
0
0
Channel 4
1
0
1
Channel 5
1
0
1
Channel 5
1
1
0
Channel 6
1
1
0
Channel 6
1
1
1
Channel 7
1
1
1
Channel 7
ER-A5RS: 2PCS
UKOG-6705RCZZ:
ER-A490
+ ER-A49R1
1
CD
2
RD
3
TD
4
ER
5
GND
6
DR
7
RS
8
CS
9
CI
2 – 1
2. RS-232 Channel 1 ~ 7 check
1
Activation
The program is activated by JOB#501~507.
SRV mode:
501  
 TL  : Channel 1
502  
 TL  : Channel 2
503  
 TL  : Channel 3
504  
 TL  : Channel 4
505  
 TL  : Channel 5
506  
 TL  : Channel 6
507  
 TL  : Channel 7
2
Contents to be tested
If the channel specified by JOB#CODE is not set, the machine
performs the mis-operation processing. When the channel is set,
the machine conducts the loop check concerning the channel
specified by JOB#CODE by using the loopback connector.
The following three items are checked:
1
Control signal check
2
Data transfer check
3
Timer check (RS-232 onboard timer)
Check 
1
Control signal check (ERn-DRn
CIn, RSn-CDn
CSn loop
check)
OUTPUT
INPUT
ERn
RSn
DRn
CIn
CDn
CSn
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
OFF
ON
ON
ON
OFF
ON
ON
OFF
OFF
ON
ON
ON
ON
ON
ON
The read check about the above INPUT items and interrupt check of
CS, CI and CD are performed.
Read check:
ER and RS are switched over in the order as
shown in the above table to confirm the logic of
DR, CI, CD and CS.If the read logic is different
from the one in the table, error print-outs occur.
Interrupt check: Allows the interruption of either of CS, CI and CD
one by one. (The mask is released.)
The interruption does not take place when each
signal is turned on. Or if the interruption occurs
when a signal is turned off, error print-outs occur.
Each of the above checks should be made in four cycles.
Note) ERn control selector jumper switch on the I/F  board must be
switched to the software control side. 
Check 
2
Data transfer check (SDn-RDn loop check)
In this check, transfer 256-byte loopback data of $00 ~ $FF.
Note) The above check should be made with the baud rate set at
9600BPS.
Check 
3
Timer check
Before making check 
2
, set the corresponding timer at 10ms
for RCVDT activation, and check to see that:
1) TRQ1 is not generated during the execution of  check 
2
.
2) TRQ1 is generated in 10msec. after check 
2
 is  finished.
3
Contents to be checked
If an error occurs during the above checks, following error print-
outs occur. Even if an error occurs during check 
1
, the test is
continued after the corresponding error print-out has occurred, but
if an error occurs during the execution of check 
2
 or 
3
, the test is
terminated after the corresponding error print-out has occurred.
Note that when check 
1
2
 or 
3
 terminates, the termination print-out
occurs irrespective of any errors that have occurred during the
check. (The program terminates normally only when no error print-
out has occurred.)
ERROR
ERROR PRINT
Contents
1
E1-ER DR
ERn-DRn ERR
2
E2-ER CI
ERn-CIn ERR
3
E3-RS CD
RSn-CDn ERR
4
E4-RS CS
RSn-CSn ERR
5
E5-CI INT
Interruption error of CIn
6
E6-CD INT
Interruption error of CDn
7
E7-CS INT
Interruption error of CSn
8
E8-TXEMP
TXEMPn error
9
E9-TXEMP I
Interruption error of TXEMPn
10
E10-TXRDY
TXRDYn error
11
E11-TXRDY I
Interruption error of TXRDYn
12
E12-RCVRDY
RCVRDYn error
(Reception is impossible. TRQ1 has
occurred during execution of check
2
.)
13
E13-RCVRDY I
Interruption error of RCVRDY
14
E14-SD RD
SDn-RDn ERR
(Data error)
15
E15-SD RD
SDn-RDn ERR
(Data error, Flaming error)
16
E16-TIMER
TIMERn error
(TMRQn cannot be set after
termination of check 
2
.)
17
E17-TIMER I
Interruption error of TRQ1
Errors that may occur during check 
(control signal check): E1 ~ E7
Errors that may occur during check 
2
 (data transfer check): E8 ~ E15
Errors that may occur during check 
3
 (timer check): E12, E16 and E17
4
Cancellation
The program automatically terminates when a check is finished.
 Termination print-out:
 
50n 
  
n  :  1 ~ 7
2 – 2
Page of 35
Display