DOWNLOAD Sharp ER-A220 (serv.man3) Service Manual ↓ Size: 918.91 KB | Pages: 64 in PDF or view online for FREE

Model
ER-A220 (serv.man3)
Pages
64
Size
918.91 KB
Type
PDF
Document
User Manual / Operation Manual
Brand
Device
ECR
File
er-a220-sm3.pdf
Date

Sharp ER-A220 (serv.man3) User Manual / Operation Manual ▷ View online

11
* Item:
Selection:
Entry:
A
VAT4 or TAX4
Yes
1
No
0
B
VAT3 or TAX3
Yes
1
No
0
C
VAT2 or TAX2
Yes
1
No
0
D
VAT1 or TAX1
Yes
1
No
0
E
SICS / Normal
SICS
1
Normal
0
F
Sign
Minus department
1
Plus department
0
G
Always enter 0.
0
H
HALO
0-7
I
Type of unit price entry
Open and preset
3
Preset only
2
Open only
1
Inhibit department key
0
•  The tax system of your machine has been factory–set to automatic VAT1–4. If you desire to
select any of automatic tax 1–4, manual VAT1–4, manual VAT1, manual tax 1–4, and the
combination of the automatic VAT 1 and the automatic tax 2–4, consult your dealer.
•  When the combination of the automatic VAT1 and automatic tax 2–4 system is selected, one of
the VAT1(D) can be selected in combination with tax 2–4.
Example: ABCD = 1001, 1010, 1100
Unit price
You can program unit prices up to a maximum of six digits (9999.99).  Even if a department is not programmed
to allow the entry of preset unit prices in functional programming, the department is automatically changed to
allow the entry of preset unit prices by this programming entry.
*To program departments 16 through 30, press the department shift key at this point.
Unit price
1000 
¯
É
Print
Key operation example
To set zero
To program another dept.
Dept. key
Unit price(max. six digits)
É
Ó
*
Tax status
From left, EHI
Sign(F)
011011073
ú É
Print
Key operation example
12
Each PLU requires you to program the following:
PLU code (three digits: 1 to 500)
Associated department
When a PLU is associated with a department, the following functions of the PLU depend on the
programming for the corresponding department.
• Tax status
• HALO (only for the subdepartment)
• Single item cash sale
• Sign
Unit price (max. six digits)
You will usually have unit prices programmed for individual PLUs as PLU preset unit prices. If you program
unit price “0” for a PLU, you can enter only the selling quantity of the PLU, i.e. the PLU can be used only
as a counter.
PLU or subdepartment mode
• If the PLU mode (i.e. automatic preset unit price entry) is selected, individual PLU entries can be made by
entering the assigned code and depressing the 
Ö
key.
• If the subdepartment mode is selected, the following key operations must be performed:  Enter the price,
press the 
å
key, enter the PLU code, and press the 
Ö
key.
Unit price and associated department assignment
*1: 1 through 500
*2: To assign departments 16 through 30, press the department shift key at this point.
PLU code
Unit price
Associated dept.
Ö
125 
˘
É
Print
Key operation example
PLU code*
1
Dept. key
Unit price 
(max. six digits)
Ö
?
To program zero
To inhibit
To program the following PLU
To program another PLU
É
Ó
*
2
Price lookup (PLU) programming
5
13
PLU/subdepartment mode
*1:   1 through 500
*2:   0 for subdepartment mode or 1 for PLU mode
Programming the rate (
%
e
*:
Rate
0.00 — 100.00 (% rate)
0.000000 — 999.999999 (Currency exchange rate)
You must use a decimal point when setting rates that are fractional.
Percent rate
Currency 
exchange rate
10 
.
25
.
6068
e
É
Print
Key operation example
*Rate
or
e
É
§
To program another rate
To program zero
Programming for miscellaneous keys
6
PLU/subdept. 
mode
Ö
Ñ É
Print
Key operation example
*
1
PLU code
Ö
To program "0"
To program the following PLU
To program another PLU
É
Ñ
*
2
A
14
Programming the discount key amount (
-
Programming the percent rate limitation (
%
)
You can program the upper limit of percent rates for percent entries.
(Percent entries that exceed the upper limit may be overridden in the MGR mode.)
10.00% can be entered as
1 0
or 
1 0 . 0 0
.  The 
.
key is needed only for
fractional entry.
Programming function parameters for 
-
and 
%
keys
+/- sign
Programming of the +/- sign assigns the premium or discount function for each key.
Item % / Item 
â
Percent/discount calculation for the individual department and PLU
Subtotal % / Subtotal 
â
Percent/discount calculation for the subtotals
Limit amount (HALO) (For discount key only)
The HALO limit is in effect for the REG-mode operations but can be overridden in the MGR mode.  The
HALO limit is represented by the number of allowable digit for the maximum entry amount for discount
key.
*ABCD
or
-
É
§
To program for another key
To program “0” for all items
Percentage limit
Ñ
29
15
.
00
É
Print
Key operation example
Ñ
29
Percentage limit (0.00 -100.00)
É
To program zero
To program for another percent key
or
∞ §
Discount amount
1000
-
É
Print
Key operation example
Discount amount (max. six digits)
É
-
To program zero
Page of 64
Display

Click on the first or last page to see other ER-A220 (serv.man3) service manuals if exist.