45
DVD-Series
TRAYMECHA Timing Chart (24)
Condition of working
While Tray 2 is open and MECHAPICK moves from the Tray 1 to the Tray 2 side
Working Mode
Tray 2 open 
_
Tray 2 closed 
_
MECHAPICK moves from the Tray 1
to the Tray 2 side
SW1B
SW1A
SW2A
MECHASW
LOAD ( + )
LOAD ( – )
*1. Point of loading to start with key operation
*2. Active point of SW1B
*3. Recognition time of SW1B”H”
*4. Switching point from high-speed mode to low-speed mode.
*5. Pulse driving (low-speed mode) time
*6. Recognition time of SW1A switching from “L” to “H”
*7. Switching point from low-speed to high-speed mode
*8. Switching point from high-speed mode to low-speed mode.
*9. Pulse driving (low-speed mode) time
*10. Active point of MECHASW
*11. Recognition time of SW2A”L”
*12. Short break time for loading motor (During this time, 100mS period after 50mS passes, overrun check for motor stop
position is performed.  If SW2A turns to “H” during this time, forward pulse drive is operated.  When SW2A turns to “L”
again, it goes back to Break Mode.  This action will be repeated a maximum of 3 times.)
*13. Waiting time before moving to the next mode.
∗ 
1
∗ 
2
 3
100ms
∗ 
5
∗ 
9
∗ 
6
∗ 
13
∗ 
7
∗ 
4
∗ 
8
∗ 
11
∗ 
10
∗ 
12
1200ms
150ms
1200ms
46
DVD-Series
TRAYMECHA Timing Chart (25)
Condition of working
From the position of Tray 2 Closed to the time for Tray 1 to be discharged
Working Mode
Tray 2 closed 
_
 MECHAPICK moves from the Tray 1 to the Tray 2
side 
_
Tray 1 open
SW1A
SW2A
SW2B
MECHASW
LOAD ( + )
LOAD ( – )
*1. Point of loading to start with key operation
*2. Active point of SW1A
*3. Recognition time of SW1A”H”
*4. Switching point from high-speed mode to low-speed mode.
*5. Pulse driving (low-speed mode) time
*6. Active point of MECHASW
*7. Recognition time of SW2A switching from “L” to “H”
*8. Switching point from low-speed to high-speed mode
*9. Switching point from high-speed mode to low-speed mode.
*10. Pulse driving (low-speed mode) time
*11. Recognition time of SW2B”L”
*12. Short break time for loading motor
*13. Waiting time before moving to the next mode.
∗ 
1
 2
∗ 
3
100ms
∗ 
5
∗ 
10
∗ 
6
∗ 
13
∗ 
8
∗ 
4
∗ 
9
∗ 
11
∗ 
7
∗ 
12
1200ms
150ms
1200ms
47
DVD-Series
TRAYMECHA Timing Chart (26)
Condition of working
From the position of Tray 2 Open to the time of Tray 1 to be discharged
Working Mode
Tray 2 open 
_
Tray 2 closed 
_
MECHAPICK moves from the Tray 1
to the Tray 2 side 
_
Tray 1 open
SW1B
SW1A
SW2A
SW2B
MECHASW
LOAD ( + )
LOAD ( – )
*1. Point of loading to start with key operation
*2. Active point of SW1B
*3. Recognition time of SW1B”H”
*4. Switching point from high-speed mode to low-speed mode.
*5. Pulse driving (low-speed mode) time
*6. Recognition time of SW1A switching from “L” to “H”
*7. Switching point from low-speed to high-speed mode
*8. Switching point from high-speed mode to low-speed mode.
*9. Pulse driving (low-speed mode) time
*10. Active point of MECHASW
*11. Recognition time of SW2A switching from “L” to “H”
*12. Switching point from low-speed to high-speed mode
*13. Switching point from high-speed mode to low-speed mode.
*14. Pulse driving (low-speed mode) time
*15. Recognition time of SW2B”L”
*16. Short break time for loading motor
*17. Waiting time before moving to the next mode.
∗ 
1
∗ 
2
∗ 
3
∗ 
7
∗ 
12
∗ 
17
∗ 
8
∗ 
10
∗ 
13
∗ 
6
∗ 
11
∗ 
4
∗ 
15
∗ 
16
∗ 
5
1200ms
1200ms
150ms
1200ms
∗ 
9
∗ 
14
100ms
48