DOWNLOAD Sharp AY-AP24 (serv.man12) Service Manual ↓ Size: 7.97 MB | Pages: 44 in PDF or view online for FREE

Model
AY-AP24 (serv.man12)
Pages
44
Size
7.97 MB
Type
PDF
Document
Service Manual
Brand
Device
Air Conditioner
File
ay-ap24-sm12.pdf
Date

Sharp AY-AP24 (serv.man12) Service Manual ▷ View online

9
AY-AP18CS
AY-AP24CS
AE-A18CS
AE-A24CS
Figure L-4. Printed Wiring Diagram for AY-AP18CS
C2
R44
OUT
C34
C33
TO 
TERMINAL BOARD
BOTTOM " N "
TO 
TERMINAL BOARD
TOP " N "
FROM 
TERMINAL BOARD
BOTTOM
 " 1 " , " BROWN "
FROM 
CLEANING
SWITCH 2
TO 
TERMINAL BOARD
TOP " 3 "
TO 
TERMINAL BOARD
TOP " 2 "
FROM 
CLUSTER
GENERATOR
FROM 
FAN MOTOR
TO 
TERMINAL BOARD
TOP " N "
FROM
TERMINAL BOARD
TOP " 1 ",  " BLACK "
FROM
  FAN MOTOR 
FROM
 THERMISTOR
FROM
CLUSTER
GENERATOR
FROM
CLEANING 
SWITCH 1
FROM
LOUVER MOTOR
BCN101 
(BCN201)
AY-AP18CS
AY-AP24CS
AE-A18CS
AE-A24CS
10
Figure L-5. Printed Wiring Diagram for AY-AP24CS
C2
R44
OUT
C34
C33
TO 
TERMINAL BOARD
BOTTOM " N "
TO 
TERMINAL BOARD
TOP " N "
TO 
TERMINAL BOARD
BOTTOM
 " 1 " , " BROWN "
FROM 
CLEANING
SWITCH 2
TO 
TERMINAL BOARD
TOP " 3 "
TO 
TERMINAL BOARD
TOP " 4 "
TO 
TERMINAL BOARD
TOP " 2 "
FROM 
CLUSTER
GENERATOR
FROM 
FAN MOTOR
TO 
TERMINAL BOARD
TOP " N "
FROM
FAN MOTOR 
FROM
 THERMISTOR
FROM
CLUSTER
GENERATOR
FROM
CLEANING 
SWITCH 1
FROM
LOUVER MOTOR
BCN101 
(BCN201)
11
AY-AP18CS
AY-AP24CS
AE-A18CS
AE-A24CS
FUNCTIONS
1.
Temperature control characteristic
1-1
COOL operation
In the “COOL” mode, the thermostat circuit is
controlled by five thermostat lines (C1 thru C5).
Figure Y-1
1-2
DRY operation
In the “DRY” mode, the thermostat circuit is
controlled by three thermostat lines (D1 thru D3).
Figure Y-2
1-3
HEAT operation
In the “HEAT” mode, the thermostat circuit is
controlled by six thermostat lines (H01 thru H4).
Figure Y-3
2.
Operation modes
2-1
COOL operation
The compressor turns on or off, at the thermostat
lines C3 and C4. The outdoor fan motor is also
controlled with the compressor.
18
32
C1
C2
C3
C4
17.5
18.5
19.5
19.0
20.5
31.5
33.0
32.5
33.5
34.5
Preset temperature (˚C)
Room temperature (˚C)
C5
Room temperature(˚C)
Preset temperature (˚C)
18
32
D1
D2
D3
17.5
18.5
19.5
31.5
32.5
33.5
Preset temperature (˚C)
H4
H3
H2
H1
H02
H01
17.5
18.5
20
21
22
23
31.5
32.5
34.0
35.0
36.0
37.0
18
32
Room temperature(˚C)
Room temperature
Preset temperature
Room 
temperature
transition
C4
C5
States 1 & 3 : Compressor ON
State 2 : Compressor OFF
1
2
3
Figure Y-4
AY-AP18CS
AY-AP24CS
AE-A18CS
AE-A24CS
12
2-2
DRY operation
On the switch on, the compressor always starts to
operate for 2 minutes with fan speed "DL" .
The microcomputer reads the room temperature 2
minutes after this first compressor operation.
This room temperature is set as the preset
temperature automatically.
The preset temperature ranges from 18˚C to
32˚C. When the room temperature is below 18˚C,
the preset temperature is  set to 18˚C, and when
the room temperature is over 32˚C, the preset
temperature is set to 32˚C.
Dry operation is divided into three zones (Cooling
zone, Dehumidifying zone and Circulating zone)
by thermostat lines (D1 to D3), and the
compressor and the fan motor are controlled in
each zone as shown in Table Y-1.
Table Y-1
2-3
Heat operation
The compressor turns on or off, at State  2  , turns on
continuously at State  1  &  3 .
Figure Y-5
Room temperature
Preset temperature
Room 
temperature
transition
D3
D2
D1
States 1 & 5 : Cooling zone
States 2 & 4 : Dehumidifying zone
States 3 : Circulating zone
3
4
5
1
2
Compressor
Cooling zone
Dehumidifying zone
Circulating zone
Fan speed
ON
"DH"
"DL"
"DL" or OFF
ON
OFF
Figure Y-6
Room temperature
Preset temperature
Room
temperature
transition
States 1 & 3 : Compressor ON
States 2  : Compressor OFF/(ON)
                  (Hot-keep function)
H1
H2
3
1
2
3.
Fan speed
Fan speeds are given by the indoor fan motor, "DL"~"HH" which are available in the following operation mode.
Table Y-2
Fan switch
DL
Fan speed
Fan switch (AUTO)
AY-AP18CS
(r.p.m.)
750
830
780
860
820
960
840
980
940
1030
1000
1120
1050
1210
720
730
840
930
870
960
940
1080
1010
1150
1050
1210
AY-AP24CS
DH
DRY
COOL
CL
COOL SOFT
CAL
CM
COOL LOW
CAH
CH
COOL HIGH
HUL
HL
HEAT SOFT
HEAT
HAL
HM
HEAT LOW
HAH
HH
HEAT HIGH
Page of 44
Display