DOWNLOAD Sharp AY-AP24 (serv.man12) Service Manual ↓ Size: 7.97 MB | Pages: 44 in PDF or view online for FREE

Model
AY-AP24 (serv.man12)
Pages
44
Size
7.97 MB
Type
PDF
Document
Service Manual
Brand
Device
Air Conditioner
File
ay-ap24-sm12.pdf
Date

Sharp AY-AP24 (serv.man12) Service Manual ▷ View online

25
AY-AP18CS
AY-AP24CS
AE-A18CS
AE-A24CS
PERFORMANCE CURVES
Figure P-1. At Cooling for AY-AP18CS
Figure P-2. At Heating for AY-AP18CS
15000
Cooling capacity (BTU/h)
2500
4.0
4.5
5.0
(kW)
(kW)
2000
Power input (W)
16
1500
15
14
13
12
11
Outside air temp.(˚C)
Inside outlet air temp. (˚C)
3 0
3 2
3 4
3 6
3 8
4 0
4 2
4 4
4 6
Indoor air temp. : 29˚C
Indoor humidity : 39RH%
Indoor fan speed : Hi
Power supply : 60Hz, 220V
Pipe length : 7.5 m
Indoor air temp. : 21˚C
Indoor fan speed : Hi
Power supply : 60Hz, 220V
Pipe length : 7.5 m
16000
17000
14000
Heating capacity (BTU/h)
Power input (W)
35
40
1500
2000
4.0
5.0
6.0
30
Outside air temp.(˚C)
Inside outlet air temp. (˚C)
- 1 0 - 8
- 6
- 4
- 2
0
2
4
6
8
1 0
13000
14000
15000
16000
17000
18000
19000
20000
AY-AP18CS
AY-AP24CS
AE-A18CS
AE-A24CS
26
Figure P-3. At Cooling for AY-AP24CS
Figure P-4. At Heating for AY-AP24CS
REFRIGERANT PIPE INSTALLATION WORKS
Refrigerant pipe length and level difference between the indoor and outdoor units.
The shorter refrigerant pipe, the highter the machine capabillity. Keep the pipe line as short as possible.
If actual pipe length exceeds 7.5m, and refrigerant (R22) 15g per 1m.
MODEL 
AY-AP18CS
AY-AP24CS
PIPE SIZE
GAS
LIQUID
STANDARD PERMISSIBLE
LENGTH
PERMISSIBLE LEVEL
DIFERENCE
1/2"
5/8"
1/4"
1/4"
15m
10m
15m
10m
22000
Cooling capacity (BTU/h)
3500
6.0
6.5
7.0
(kW)
(kW)
3000
Power input (W)
14
2500
13
12
11
10
9
Outside air temp.(˚C)
Inside outlet air temp. (˚C)
3 0
3 2
3 4
3 6
3 8
4 0
4 2
4 4
4 6
Indoor air temp. : 29˚C
Indoor humidity : 39RH%
Indoor fan speed : Hi
Power supply : 60Hz, 220V
Pipe length : 7.5 m
Indoor air temp. : 21˚C
Indoor fan speed : Hi
Power supply : 60Hz, 220V
Pipe length : 7.5 m
23000
24000
21000
Heating capacity (BTU/h)
Power input (W)
40
45
2000
2500
3000
4.0
5.0
6.0
7.0
8.0
9.0
35
Outside air temp.(˚C)
Inside outlet air temp. (˚C)
- 1 0 - 8
- 6
- 4
- 2
0
2
4
6
8
1 0
13000
14000
15000
16000
17000
18000
19000
20000
27
AY-AP18CS
AY-AP24CS
AE-A18CS
AE-A24CS
DISASSEMBLING PROCEDURE
FOR INDOOR UNIT MODEL [AY-AP18CS / AY-AP24CS]
CAUTION:DISCONNECT THE UNIT FROM THE POWER SUPPLY BEFORE ANY SERVICING
1.
Open the Opne panel, remove 2 Air Filters.
2.
Open the Louver frame.unlook the hooks,and pull
the unit.
3.
Remove 6 screws fixing the Front panel.
4.
Remove the screw fixing the Cord holder.
AY-AP18CS
AY-AP24CS
AE-A18CS
AE-A24CS
28
5.
Close the Open panel. pushing the nail of the
Front panel, and lift the Front panel up.
6.
Remove the unit-to-unit wiring from the Terminal
board.
7.
Remove a screw fixing the Control box cover.
8.
Cut the fixing band and Remove the Cover B.
9.
Remove a screw fixing the ground wire.
Page of 44
Display

Click on the first or last page to see other AY-AP24 (serv.man12) service manuals if exist.