DOWNLOAD Sharp AE-XM24CR (serv.man17) Service Manual ↓ Size: 7.74 MB | Pages: 88 in PDF or view online for FREE

Model
AE-XM24CR (serv.man17)
Pages
88
Size
7.74 MB
Type
PDF
Document
Service Manual
Brand
Device
Air Conditioner
File
ae-xm24cr-sm17.pdf
Date

Sharp AE-XM24CR (serv.man17) Service Manual ▷ View online

69
AY-XM7/9/12CR
AY-XPM7/9/12CR
AE-XM18/24CR
How to disassemble the control box
assembly
15. Cut the 3 wire fixing bands.
Disconnect the 5 connectors.
(CN6,CN15,CN5B,CN9B,CN7)
CAUTION: Fix the connector of the power module
securely.
Then lift up the control board unit (PWB) and remove it.
16 .Unscrew the 3 screws fixing the power supply board
unit (PWB).
Unscrew the 1 screw fixing the PTC thermistor.
Unscrew the 1 screw fixing the fan motor capacitor.
17. Disconnect the 2 terminals (Blue). (A3AEXM24CR
only). Disconnect the 2 terminals (Brown).
And unscrew the 3 screws fixing the terminal board
angle assembly then turn it inside out.
18. Unscrew the 2 screws fixing the transformer then
remove the power supply board unit (PWB).
19. Disconnect 2 connectors (CN1,CN9). Then lift up the
relay board unit (PWB) and remove it.
Power 
transistor 
module
NG
OK
20. Unscrew the 2 screws fixing the heat sink cover then
remove it.
70
AY-XM7/9/12CR
AY-XPM7/9/12CR
AE-XM18/24CR
21. Disconnect the 6 terminals(IN+,IN-,L+,L-,OUT+,
OUT-) and 1 connector (CN13) on the active filter.
And unscrew the 2 screws fixing the active filter and
remove it.
Note : When the active filter re-install, silicone
grease must be paste to the back face of the
active filter.
22. Unscrew the 4 screws fixing the heat sink
Note : Seal the 4 burring holes with silicone sealer
before re-installing.
23. Disconnect the 5 terminals(P(+),N(-),U,V,W) and 2
connectors (CN5A,CN14) on the power transistor
module (IPM). And unscrew the 4 screws fixing the
power module and remove it.
Note : When the power module re-install, silicone
grease must be paste to the back face of the
power module.
71
AY-XM7/9/12CR
AY-XPM7/9/12CR
AE-XM18/24CR
1
Take out the air filters.
  Open the open panel.
  Push the air filters up slightly to unlock
them.
Pull the air filters down to remove
Take of the old dust collection filter 
and the deodorant filter from the air filter. 
Snap out in the arrow marked direction. 
Set the new dust collection filter and 
the deodorant filter with filter stoperts 
located on the air filters.
them.
2
Check the filters.
3
Reinstall the air filters
  Reinstall the air filters in the original
positions.
Close the open panel.
Push the arrow-marked of the panel
firmly to lock it in place.
DUST COLLECTION FILTER (gray)
Set the black side facing upward.
Filter stopper
DEODORANT FILTER (green)
Filter stopper
2
3
3
1
2
HOW TO  REPLACE THE 
DUST COLLECTION FILTER AND DEODORANT FILTER
(only for models AY-XPM7CR/AY-XPM9CR/AY-XPM12CR)
Precautions
The dust collection filter and the deodorant filter are packed as accessory of this unit.
During operation of the air conditioner, the filters remove dust and tobacco smoke
from the air and discharges clean air.
• The filters are sealed in a plastic bag to keep their dust collection effect.
  Do not open the bag until using the filters. (Otherwise the filters life may get shorter.)
• Do not expose the filters to direct sunlight. (Otherwise they may deteriorate.)
1
3
2
 
 
1
  1
3
2
 2
2
72
AY-XM7/9/12CR
AY-XPM7/9/12CR
AE-XM18/24CR
CLEANING THE DEODORANT FILTER (GREEN)
The filter should be cleaned every 3~6 months
1
REMOVE THE AIR FILTERS
2
CLEAN THE DEODORANT FILTER
Take off the deodorant filter from the air
filters.
Soak the deodorant filter in mild detergent
dilution for 10 to 20 minutes.
Rinse thoroughly with water, dry completely
under sunlight.
Set the clean deodorant filter under the fil-
ter stoppers located on the air filters.
3
REINSTALL THE AIR FILTERS
NOTE
:
• Replacement is necessary at the interval of 3 years, as the deodorising effect will
deteriorate.
The new filters are available at your nearest dealer.
Replacement filter: Type AZ-F910C
CHANGING THE DUST COLLECTION FILTER (GRAY)
The filter should be changed every 3~6 months
1
REMOVE THE AIR FILTERS
2
CHANGE THE DUST COLLECTION FILTER
Take off the old dust collection filter from
the air filters.
Set the new dust collection filter, the black
side facing upward, under the filter stop-
pers located on the air filters.
3
REINSTALL THE AIR FILTERS
NOTE
:
• The dirty dust collection filter is not washable for reuse.
The new filters are available at your nearest dealer.
Replacement filter: Type AZ-F900C
Filter stopper
Filter stopper
Page of 88
Display

Click on the first or last page to see other AE-XM24CR (serv.man17) service manuals if exist.