What to Odor Sensor react to ?
Odor Sensor reacts to tobacco smole, motor exhaust,
odor emitted from animals, etc.
Allergen sensor an Odor Sensor also may react to
vapour of insecticides, cosmetics, alcohol, hemicals
and the like, and to extreme change of temperature /
humidity.
(2) Detection of the air contamination by the fluctuation ratio of sensor resistance
The output voltage from the odor sensor is input into the indoor unitÅfs microcomputer to detect the air
contamination.
This method detects the air contamination by converting sensor output voltage into the sensor resistance value
and calculating its fluctuation ratio per unit of time. Therefore, the sensor determines that the air is contaminated
when the sensor resistance value drops abruptly.
(3) Operation of the indoor unitÅfs microcomputer
When the air conditioner is plugged in, the indoor unitÅfs microcomputer starts operating and, after 1 minute,
starts detecting the air contamination.
(4) Switching sensitivity of the odor sensor
The sensitivity of the odor sensor can be adjusted when the sensor is too responsive or unresponsive.
It is set as standard at the factory.
Sensitivity is divided into three levels: high, standard, and low.
The contamination is detected when the sensor resistance drops below following percentages compared to the
reference value in a clean state.
(This is equal to the description of the resistance of the allergen sensor.)
3. DESCRIPTION OF THE OPTIAL ALLERGEN SENSOR
(1) Outline of the optical allergen sensor
As with the odor sensor, this sensor is used to display the clean sign during the operation. The pulse signal is output
from the microcomputer into the basic circuit show in the figure below, and the sensor signal is input into the
microcomputer according to the size or amount of the dust.
Output
Output
R39
1
2
3
4
5
6
12V
C29
C30
Q6
R38
R40
R72
Input
Input
50Hz : 20.0 ms
60Hz : 16.6 ms
Basic circuit
Allergen 
sensor
Clean
Contaminated
Reference value (R0)
Smoking start
Determined value K
New reference value (R0)
Additional operation
1 min.
Time
Determined 
clean
Determined 
contaminated
High (85%)
Standard (80%)
Low (75%)
15k
15k
13k
13k
R7
R6
P.W.B.
34
AY-XM7/9/12CR
AY-XPM7/9/12CR
AE-XM18/24CR
(2) Dust detection by using the sensor
The output voltage from the optical allergen sensor is input into the indoor unitÅfs microcomputer to detect the air
contamination (dust). This method inputs the sensor voltage per unit of time and calculates the relative fluctuation
to determine whether the air is contaminated or not.
(3) Operation of the indoor unit's microcomputer
As with the odor sensor, the indoor unitÅfs microcomputer starts constantly detecting the air contamination level
after 1 minute of the operation start.
(4) Switching sensitivity of the optical allergen sensor
The sensitivity can be adjusted. However, both sensors will be adjusted to the same level. The air contamination is
detected in the following seconds at each sensor level.
Clean
Contaminated
Determined 
clean
Determined 
contaminated
Reference 
value
High (2 sec.)
Med (3 sec.)
Low (4 sec.)
15k
15k
13k
13k
R7
R6
35
AY-XM7/9/12CR
AY-XPM7/9/12CR
AE-XM18/24CR
TIPS ABOUT INDICATOR PANEL
The indicator panel will change each time you press
the DISPLAY button in the following manner.
The room
temperature and
POWER MONITOR
are displayed.
The outdoor
temperature and
POWER MONITOR
are displayed.
No display.
POWER MONITOR
When the room temperature or the outdoor temperature is displayed, the POWER MONITOR
will light up in 4 levels for COOL and HEAT modes (3 levels for DRY mode), to indicate the
operation power. When the air conditioner is operating at maximum power in the COOL and
HEAT modes, "POWER" will light and "ECO" will turn off on the indicator panel.
NOTES:
• The displayed temperatures are rough estimates and may vary from the actual tempera-
tures.
• Temperature display ranges
Room temperature: 0
°C ~ 40°C (   is displayed when less than 0°C and   when higher
than 40
°C)
Outdoor temperature: -9
°C ~ 45°C (    is displayed when less than -9°C and    when
higher than 45
°C)
 is displayed during the first 120 seconds of operation while the temperatures are being
detected. (Temperature detection may more than 120seconds when other unit(s) is/are
already being operated.)
 is displayed for 5 seconds when the unit is not in operation.
DISPLAY
FULL
POWER
ECO
ECO
Room Temp. 
Lamp
Outdoor Temp.
Lamp
temperature
Indiactor
POWER 
MONITOR
ECO
ECO
Room Temp. Lamp
Outdoor Temp. Lamp
temperature
Indiactor
POWER MONITOR
(AY-XPM7CR/AY-XPM9CR/AY-XPM12CR)
(AY-XM7CR/AY-XM9CR/AY-XM12CR)
36
AY-XM7/9/12CR
AY-XPM7/9/12CR
AE-XM18/24CR
 ".
• The red OPERATION lamp ( 
The red OPERATION lamp ( 
Press the SELF CLEAN button when the unit is not
operating.
  ) and the blue
PLASMACLUSTER lamp on the unit will light up.
• The unit will stop operation after forty minutes.
• The remaining operation time will be indicated on the
TEMPERATURE INDICATOR of the indoor unit in
minute decrements.
TO CANCEL
Press the SELF CLEAN button.
Or, turn the unit off by pressing the ON/OFF button.
• The red OPERATION lamp ( 
  ),the blue
PLASMACLUSTER lamp and the TEMPERATURE
INDICATOR on the unit will turn off.
1
When the unit is in operation, press the
PLASMACLUSTER button to select the mode.
PLASMACLUSTER AUTO
AIR CLEAN
REFRESHING
CANCEL
• In the AIR CLEAN operation, the blue
PLASMACLUSTER lamp on the unit will light up.
• In the REFRESHING operation, the green
PLASMACLUSTER lamp on the unit will light up.
TO CANCEL
Press the PLASMACLUSTER button until
PLASMACLUSTER symbol on the remote control
display goes off.
• The PLASMACLUSTER lamp on the unit will turn off.
NOTE
:
• You cannot set the temperature, fan speed, air flow direction or timer setting during the SELF
CLEAN operation.
1
SWING
CLEAN
FAN
SET/C
AM
NOTES:
You can choose PLASMACLUSTER AUTO OPERATION, AIR CLEAN OPERATION or
REFRESHING OPERATION
• Setting of the PLASMACLUSTER operation will be memorized and will operate in the same
mode, the next time you turn on the air conditioner.
• To turn off the PLASMACLUSTER lamp, press the DISPLAY button.
• When the PLASMACLUSTER button is pressed while the unit is not operating, the
PLASMACLUSTER operation will be performed without accompanying air conditioning mode
(eg. HEATING or COOLING).The mode symbol of the remote control will go off and the fan
speed can not be set AUTO. At this time, you may feel HEATING is performed with units in other
rooms. Indoor fan will decrease its rotating speed and will ture ON and OFF depending on the
room temperature.
SWING
CLEAN
FAN
MODE
SET/C
1h
AM
AUTO
PLASMACLUSTER OPERATION
SELF CLEAN OPERATION
1
1
(only for models AY-XPM7CR/AY-XPM9CR/AY-XPM12CR)
(only for models AY-XPM7CR/AY-XPM9CR/AY-XPM12CR)
Page of 88
Display

Click on the first or last page to see other AE-XM24CR (serv.man17) service manuals if exist.