Panasonic TX-29P250T Service Manual ▷ View online

5.8. COLOUR PURITY
 1. Operate the TV set for over 60 minutes.
 2. Receive a purity pattern signal. (white pattern)
 3. Set Bright and Contrast controls to their maximum
positions.
 4. Set V-POS to 128.
 5. Adjust roughly the static convergence magnets.
 6. Fully
degauss
the
picture
tube
using
an
external
degaussing coil.
 7. Loosen a clamp screw for the deflection yoke and move the
deflection yoke as close to the purity magnet as possible.
 8. Adjust the purity magnet so that a vertical green field is
obtained at the center of the screen.
 9. Slowly press the deflection yoke and set it where a uniform
green field is obtained.
 10. Adjust roughly the Low Light controls and make sure that a
uniform white field is obtained.
 11. Tighten the clamp screw.
5.9. CONVERGENCE
 1. INSTRUMENT
 a. Helmhortz device
 2. PREPARATION
 a. Set the Helmhortz device to local magnetic field.
Horizontal : 0 ± 0.03 x10
-4
T
 b. Receive the cross hatch pattern.
 c. 
Picture menu : DYNAMIC Normal and adjust BRIGHT
DAC until gray portion of cross hatch.
 d. Set DY to CRT not to tilt (up and down and left and
right).
 3. ADJUSTMENT
 a. Static convergence Adjustment
 a. Make sure that magnets are positioned shown in
Fig. 1.
 b. Adjust 4-pole magnets (Fig. 1) to align center dots of
R and B and adjust 6-pole magnets to align center
dots to G.
 c. 
After adjustment, secure magnets with magnet lock
of white lacquer.
*Beams move with rotating when static magnets are
turned.
Rotational reduce of beams differs by angle of two
magnets.
Therefore, repeat magnet adjustments several times
so that all are aligned completely.
Fig. 1
 b. YHC, YV, XV, Adjustment (Fig. 2)
 a. Adjust so that Static and Dynamic convergence is
best with YHC, VR, YV and XV coil.
In case of static convergence is tilted, repeat (1)
Static convergence Adjustment.
Fig. 2
 c. 
Dynamic convergence Adjustment
 a. When dynamic convergence is bad, fixing permalloy
between neck and DY so that dynamic convergence
is best.
 4. Confirm that left upper side line is straight.
When left upper side line isn’t straight, put magnet on DY
and adjust the left upper side line to straight.
17
             TX-29P250T
5.10. CUT OFF
Preparation
 1. Receive a colour bar signal with colour “OFF”, and operate
the TV set more than 15 minutes.
 2. Set the picture menu to “DYNAMIC NORMAL” and the AI to
off.
 3. Connect an oscilloscope to TPL7 with DC mode.
 4. Set the TV set to Service Mode 1.
 5. Screen VR : Min.
 6. Set the data level of SUB BRIGHT, R, G, B-CUTOFF and
R, G, B-DRIVE to the table values.
Display
Date Level
R High (R-CUT OFF)
128
G High (G-CUT OFF)
128
B High (B-CUT OFF)
128
R Low (R-DRIVE)
175
G Low (G-DRIVE)
175
B Low (B-DRIVE)
175
SUB BRIGHT
128
Adjustment
 1. Select G-CUTOFF adjustment mode and collapse vertical
scan.
 2. Adjust G-CUTOFF control to become the DC=0V to video
level at 180V as shown below.
 3. Slowly turn the screen control clockwise until a green colour
horizontal line appears on the picture tube. This is the
setting point for the screen control.
Note that do not adjust the G-CUTOFF setting in the
following procedure.
 4. Adjust the remained R and B-CUTOFF controls so as to get
a white horizontal line on the screen.
 5. Return to full field SCAN by pushing the position 5 key on
the remote control.
 6. Adjust the R-Drive and B-Drive controls as to obtain uniform
white on the white bar of the greyscale pattern.
 7. Confirm correct B/W rendition and greyscale tracking or
repeat CUTOFF and drive control setup.
Note:
Write down the original value for each address adjustment
before adjusting anything.
 8. Wedge A shown in Fig. 1 should be fixed within a range of
45° to the left of the vertical line as shown.
 9. After inserting wedge A, insert wedges B, C and D.
The wedges should be set 90° apart from each other.
 10. Be certain that the four wedges are firmly fixed and the
deflection yoke is tightly clamped in place otherwise the
deflection yoke may shift its position and cause a loss of
convergence and purity.
18
             TX-29P250T
5.11. WHITE BALANCE
Item/Preparation
Adjustment Procedure
 1. 
Select Service Mode 1.
 2. 
Aging should have been performed over 30 minutes
 3. 
Receive the white balance pattern.
 4. 
Picture menu : DYNAMIC NORMAL
AI : OFF
 5. 
Degauss the CRT face.
 6. 
Connect the photo sensors of the Colour Analyser to the
CRT.
Note:
CRT cut off adjustment is completed.
 1. 
Adjustment of Low Light
 a. 
Adjustment SUB BRIGHT, so that “Y” axis indicates 6.5
 b. Adjustment R-CUT OFF, so that y axis indicates 0.267.
 c. Adjustment B-CUT OFF, so that x axis indicates 0.269.
 2. 
Adjustment of High Light
 a. 
Adjust SUB BRIGHT, so that “Y” axis indicates 150.
 b. Adjust R-DRIVE, so that y axis indicates 0.272.
 c. Adjust B-DRIVE, so that x axis indicates 0.2.
5.12. Focus
Item/Preparation
Adjustment Procedure
 1. 
Receive a cross-hatch pattern signal.
 1. 
Adjust the Focus to thin all the Lines by Focus 1 Control.
(Prefer to thin the Vertical Lines than Horizontal Line.)
 2. 
Adjust the Focus to thin the Horizontal Lines by Focus 2
Control.
5.13. Geomagnetic
Item/Preparation
Adjustment Procedure
 1. 
Demagnetize the GM-Board around its perimeter with the
Demagnetizer.
 1. 
Connect a DC voltage meter to TPGM1-2pin (GM-Board)
 2. 
Adjust the R4863 (GM-Board) so that the Vx Out at TPGM1-
2pin becomes 4.9 ± 0.05 V
 3. 
Connect a DC voltage meter to TPGM1-1pin (GM Board).
 4. 
Adjust the R4861 (GM-Board) so that the Vy Out at TPGM1-
1pin becomes 4.9 ± 0.05 V
5.14. SUB BRIGHT
Item/Preparation
Adjustment Procedure
 1. 
Receive the sub bright pattern.
 2. 
Picture Menu:
BRT.......... ........CENTER
COLOUR..........CENTER
CONT...............MAX
 3. 
Connect the photo sensor of the Colour Analyser to the
center of the CRT.
 1. 
Adjust Sub Bright so that brightness level becomes 1 ± 0.2
cd/m
2
.
19
               TX-29P250T
6 DEFLECTION ADJUSTMENT
6.1. V-ADJUSTMENT/CONFIRMATION (4:3 MODE)
6.1.1. V-HOLD CONFIRMATION
 1. Receive PAL monoscope pattern
 2. Set scan mode to 100Hz by remote control key
 3. Set aspect to 4:3
 4. Confirm that V-hold is normal
 5. Set the fix data in the table 1.
6.1.2. V-CENTER ADJUSTMENT (4:3 MODE)
6.1.2.1. 100I V-POS ADJUSTMENT
 1. Receive PAL monoscope pattern.
 2. Set scan mode to 100Hz by remote control key.
 3. Adjust V-POS (100i / 4:3) so that the scale of the top and bottom side is equal.
6.1.2.2. 120i V-POS ADJUSTMENT
 1. Receive NTSC monoscope pattern.
 2. Set scan mode to 100Hz by remote control key.
 3. Adjust V-POS (120i / 4:3) so that the scale of the top and bottom side is equal.
6.1.2.3. 50p V-POS ADJUSTMENT
 1. Receive PAL monoscope pattern.
 2. Set scan mode to progressive by remote control key.
 3. Adjust V-POS (50p / 4:3) so that the scale of the top and bottom side is equal.
6.1.2.4. 60p V-POS ADJUSTMENT
 1. Receive NTSC monoscope pattern.
 2. Set scan mode to progressive by remote control key.
 3. Adjust V-POS (60p / 4:3) so that the scale of the top and bottom side is equal.
Fig. 1
6.1.3. V-HEIGHT ADJUSTMENT (4:3 MODE)
6.1.3.1. 100i V-AMP ADJUSTMENT
 1. Receive PAL monoscope pattern.
 2. Set scan mode to 100 Hz by remote control key.
 3. Adjust V-AMP (100i / 4:3) so that B, D (Fig. 2) is 2.1± 0.1.
6.1.3.2. 120i V-AMP ADJUSTMENT
 1. Receive NTSC monoscope pattern.
 2. Set scan mode to 100 Hz by remote control key.
 3. Adjust V-AMP (120i / 4:3) so that B, D (Fig. 2) is 2.1± 0.1.
6.1.3.3. 50p V-AMP ADJUSTMENT
 1. Receive PAL monoscope pattern.
20
             TX-29P250T
Page of 67
Display