53
KX-TG6611RU/KX-TG6611UA/KX-TG6611CA/KX-TG6612CA/KX-TGA661RU
11.6. Adjustment Standard (Handset)
When connecting the simulator equipment for checking, please refer to below.
11.6.1. Component View
Note:
(A) - (Ris referred to Check Point (Handset) (P.38)
KX-TGA661/660 xx 
TGA806/805 xx
A
PNLB1897Z
PbF
-GW
SP-PHONE
CP_V2
RECEIVER
GND
BAT
UTX
URX
MIC-
MIC+
1.8V
CP2.8V
JTAG
CP3.0V
E
BLU
ORG
POWER
CKM
C2
C3
C1
F1
2.5A
X1
1
BATT+
BATT-
CHG(+)
CHG(-)
IC7
ORG
GRN
CN4
C190
C702
C701
C79
C52
C51
C189
C40
C55
C110
C73
C33
C14
C13
C11
C48
C47
C43
C822
C823
C820
C864
C863
C810
C805
C803
C806
C812
L803
C837
C866
C45
STM
C814
C152
C72
C76
C32
C86
C185
C343
C340
C8
C19
C7
C150
C113
ANT-Short-GND
ANT-Short
AT1
R203
R807
R806
R19
R76
R32 R34
R215
R306
R10
R8
R6
R9
L48
L74
IC1
IC3
RA4
RA40
RA30 RA31
RA61
DA801
D3
D2
Q7
Q6
Q5
Q9
C96
C17
C18
C97
C12
C16
C184
C39
C83
C53
C44
C865
C138
C139
C175
C174
C71
C70
C173
C804
C802
C46
C811
C825
C813
L802
C826
C54
C809
C49
C188
C10
C78
C50
C127
C82
C77
C704
C172
C341
C342
C344
C345
C35
C34
C74
C5
C75
R5
R66
R63
R64
RF-SHIELD
R7
R25
R28
R27
R23
R29
R22
R18
R77
R20
R100
R101
R1
R33
R31
R45
R31
R4
R30
L46
L9
L47
L308
L72
IC4
C9
RA1
RA32
D21
D22
D14
D13
D1
Q2
Q4
AF
Generator
MIC-
MIC+
+
+
DC Power
5.0V
2.7 V
Zener
Frequency
Counter
GND
CP_V2
CKM
U-ART
22pF
100
DECT Tester
CMD60
Oscilloscope
AF Volt Meter
34
8
56
1F
DC POWER
2.00 - 2.25 V
(at battery low)
Power key
CHG+
CHG-
56
VDD
1.8V
CP3.0V
ANT
(I)(J)(K)(L)
(M)(N)
(O)
(P)
(Q)
CP2.8V (S)
(O)
(D)
(E)
(F) 
(G)
(A)
(H)
(R)
(A)
(B)(C)(F)
(H)(I)
GND
RX
TX
GND
DC Power
2.30 - 2.60 V
PC
Connect between ANT-Short and ANT-Short GND.
54
KX-TG6611RU/KX-TG6611UA/KX-TG6611CA/KX-TG6612CA/KX-TGA661RU
11.7. Things to Do after Replacing IC or X'tal
If repairing or replacing BBIC (FLASH type), EEPROM and X'tal, it is necessary to download the required data such as
Programming data or adjustment data, etc in memory.
The set doesn't operate if it is not executed.
11.7.1. How to download the data
11.7.1.1. Base Unit
First, operate the PC setting according to The Setting Method of JIG (Base Unit)(P.47).
Then download the appropriate data according to the following procedures.
Note:
(*1) XXX_YYY: revision number, WW: destination code
“XXX_YYY” vary depending on the country version. You can find them in the batch file, PNZZ- mentioned in The Setting
Method of JIG (Base Unit)
 (P.47).
(*2) Refer to Check Point (Base Unit) (P.35)
Items
How to download/Required adjustment
FLASH(IC431)
Programming data is stored in memory.
1) Make sure to connect the JIG cable, then disconnect the DC
Power in order to download the data.
2) Execute the command “flw441 *********.hex”.
3) Connect the DC Power.
4) Press the PC Enter key once.
5) After a few minutes, “Successful upgrade” is displayed on the
PC indicating downloading has finished.
6) Detach the JIG cable, then disconnect the DC Power.
7) Connect the DC Power.
8) Connect the JIG cable again, and execute the command
“getchk”, then confirm the checksum value is correct.
• If the downloading fails, start again from step 1).
9) Default batch file: Execute the command “default.bat”.
10) Country version batch file: Execute the command
“TG6611EU_WW_RevXXX_YYY.bat”. (*1)
11) Clock adjustment: Refer to Check Point (G). (*2)
EEPROM (IC401)
Adjusted parameter data is stored in memory.
(country version batch file, default batch file,
etc.)
1) Change the address “0001” of EEPROM to “55” to download
the data.
2) Default batch file: Execute the command “default.bat”.
3) Country version batch file: Execute the command
“TG6611EU_WW_RevXXX_YYY.bat”. (*1)
4) Clock adjustment: Refer to Check Point (G). (*2)
X'tal (X1)
System clock
Clock  adjustment  data is in EEPROM, adjust the data again
after replacing it.
1) Refer to Check Point (F). (*2)
55
KX-TG6611RU/KX-TG6611UA/KX-TG6611CA/KX-TG6612CA/KX-TGA661RU
11.7.1.2. Handset
First, operate the PC setting according to The Setting Method of JIG (Handset)(P.51).
Then download the appropriate data according to the following procedures.
Note:
(*3) XXX_YYY: revision number, WW: country code
“XXX_YYY” vary depending on the country version. You can find them in the batch file, PNZZ- mentioned in The Setting
Method of JIG (Handset)
 (P.51)
.
(*4) Refer to Check Point (Handset) (P.38)
Items
How to download/Required adjustment
FLASH(IC4)
Programming data is stored in memory.
1) Make sure to connect the JIG cable, then disconnect the DC
Power in order to download the data.
2) Execute the command “flw441 *********.hex”.
3) Connect the DC Power.
4) Press and hold the handset Power key.
5) While holding down the handset Power key, press the PC
Enter key once.
6) After a few minutes, “Successful upgrade” is displayed  on
the PC indicating downloading has finished.
7) Detach the JIG cable, then press the handset Power key to
turn it on.
8) Connect the JIG cable again, and execute the command
"getchk”, then confirm the checksum value is correct.
• If the downloading fails, start again from step 1).
9) Default batch file: Execute the command “default.bat”.
10) Default batch file (remaining): Execute the command
“TGA660RU_DEF_RevXXX_YYY.bat”. (*3).
11) Country version batch file: Execute the command
“TGA660RU_WW_RevXXX_YYY.bat”. (*3).
12) Clock adjustment: Refer to Check Point (H). (*4).
13) 1.8 V setting and battery low detection: Refer to Check
Point (A), (F) and (G). (*4).
EEPROM (IC3)
Adjusted parameter data is stored in memory.
(country version batch file, default batch file,
etc.)
1) Change the address “0001” of EEPROM to “55” to download 
the data.
2) Default batch file: Execute the command “default.bat”.
3) Default batch file (remaining): Execute the command 
“TGA660RU_DEF_RevXXX_YYY.bat”. (*3)
4) Country version batch file: Execute the command 
“TGA660RU_WW_RevXXX_YYY.bat”. (*3)
5) Clock adjustment: Refer to Check Point (H). (*4)
6) 1.8 V setting and battery low detection: Refer to Check Point 
(A), (F) and (G). (*4)
X'tal (X1)
System clock
Clock adjustment data is in EEPROM, adjust the data again
after replacing it.
1) Refer to Check Point (C). (*4)
56
KX-TG6611RU/KX-TG6611UA/KX-TG6611CA/KX-TG6612CA/KX-TGA661RU
11.8. RF Specification
11.8.1. Base Unit
*: Refer to Check Point (Base Unit) (P.35)
11.8.2. Handset
**: Refer to Check Point (Handset) (P.38)
Item
Value
Refer to -. *
TX Power
19 dBm ~ 25 dBm
Check Point (Base Unit) (J)
Modulation
-350 ± 50/+350 ± 50 kHz/div & Modulated
width   610 kHz
Check Point (Base Unit) (K)
Frequency Offset
< ± 20 kHz
Check Point (Base Unit) (L)
Frequency Drift 
< ± 20 kHz / msec
Check Point (Base Unit) (M)
RX Sensitivity
< 1000 ppm
Check Point (Base Unit) (N)
Timing Accuracy
< ± 5.0 ppm/<±15.0ppm
Check Point (Base Unit) (O)
Power RAMP
Power RAMP is matching
Check Point (Base Unit) (P)
Item
Value
Refer to -. **
TX Power
19 dBm ~ 25 dBm
Check Point (Handset) (I)
Modulation
-350 ± 50/+350 ± 50 kHz/div & Modulated
width   610 kHz
Check Point (Handset) (J)
Frequency Offset
< ± 20 kHz
Check Point (Handset) (K)
Frequency Drift 
< ± 20 kHz / msec
Check Point (Handset) (L)
RX Sensitivity
< 1000 ppm
Check Point (Handset) (M)
Power RAMP
Power RAMP is matching
Check Point (Handset) (N)
Page of 82
Display

Click on the first or last page to see other KX-TG6611RUB / KX-TG6611RUM / KX-TG6611UAB / KX-TG6611UAM / KX-TG6611CAB / KX-TG6611CAM / KX-TG6612CAB / KX-TGA661RUB / KX-TGA661RUM service manuals if exist.