DOWNLOAD LG LB-F3060HL / LB-F3060CL Service Manual ↓ Size: 1.07 MB | Pages: 39 in PDF or view online for FREE

Model
LB-F3060HL LB-F3060CL
Pages
39
Size
1.07 MB
Type
PDF
Document
Service Manual
Brand
Device
Air Conditioner
File
lb-f3060hl-lb-f3060cl.zip
Date

LG LB-F3060HL / LB-F3060CL Service Manual ▷ View online

Product Specifications (Cooling & Heating) 
30,000(7,560)
30,000(7,560)
30,000(7,560)
5.0
1, 220-240, 50
28
63
3,000
3,000
2,500
14 
14.2
12
10
10
1,180 x 298 x 600
870 x 800 x 320
870 x 655 x 320
46
46
55
52
2.5
1.95
L.C.D
3/8" (9.52)
5/8" (15.88)
22.6(25.4)
0.75mm
2
¤C
3.5mm
2
¤C
O
O
3 (Hi, Med, Low)
24Hrs
O
Air Circulation
m
3
/min
Dimensions
(W
¡¿
H
¡¿
D)
Net. Weight
mm
kg
W
A
LB-F3060HL
LB-F3060CL
–5–
Service Valve & 
Connecting Tube
Model Name
Unit
Item
Cooling Capacity
Btu/h(kcal/h)
Heating Capacity
Btu/h(kcal/h)
Moisture Removal
l
/h
Power Source
Ø, V, Hz
Indoor
Outdoor
Input
Cooling
Heating
Running Current
Cooling
Heating
E.E.R.
Btu/h-W
Indoor
Outdoor
Indoor
Outdoor
Refrigerant (R-22)
g
Remocon Type
Liquid
Gas
Drain Hose
ID(OD)
Connecting Wire
Main Power Cable
Time Delay Safety Function
Soft Dry
Fan Speed (Indoor)
Timer
Self-Diagnosis
Functions
ƒU
Room temperature sensor. (Thermistor)
ƒU
Maintains the room temperature in accordance with the Setting Temp. 
ƒU
Indoor fan is delayed for 5 seconds at the starting.
ƒU
Restarting is inhibited for approx. 3 minutes.
ƒU
High, Med, Low
ƒU
Intermittent operation of fan at low speed.
ƒU
Both the indoor and outdoor fan stops during defrosting.
ƒU
Hot start after defrost ends.
ƒU
The indoor fan stops until the evaporator piping temperature will be reached at 28°C.
Indoor Unit
Operation ON/OFF by Remote controller
Sensing the Room Temperature
Room temperature control
Starting Current Control
Time Delay Safety Control
Indoor Fan Speed Control
Soft Dry Operation Mode
Deice (defrost) control (Heating)
Hot-start Control (Heating)
–3–
–4–
Remote Controller
Operation ON/OFF
Operation Mode Selection
Fan Speed Selection
Room Temperature Display
Temperature Setting
Setting the Time or Timer
(Low)
(Med)
(High)
Cooling Operation Mode (       )
Heating Operation Mode (       )
Soft Dry Operation Mode (       )
Fan Operation Mode
(Heating 
model only)
(Cooling 
model only)
HI
MED
LO
Set
: High:39°C
¡Œ
LOW:11°C
: Fan Operates without cooling & heating
Although the air conditioner is turned off by a power failure, it is restarted 
automatically after a power resupply.
Cooling
Heating 
Down to 18°C
Up to 30°C
,
Down to 16°C
Up to 30°C
,
–14–
Installation of Indoor, Outdoor Unit
1. Selection of the best location
1) Indoor unit 
Select location
Install the air conditioner in the location that satis-
fies the following conditions.
• The place shall easily bear a load exceeding four
times the indoor unit’s weight.
• The place shall be able to inspect the unit as the
figure.
• The place where the unit shall be leveled.
• The place shall allow easy water drainage.(Suit-
able dimension “H” is necessary to get a slope to
drain as figure.)
• The place shall easily connect with the outdoor
unit.
• The place where the unit is not affected by an
electrical noise.
• The place where air circulation in the room will be
good .
• There should not be any heat source or steam
near the unit.
2) Outdoor unit
• If an awning is built over the unit to prevent
direct sunlight or rain exposure, be careful that
heat radiation from the condenser is not restrict-
ed. 
• There should not be any animals or plants which
could be affected by hot air discharged. 
• Ensure the spaces indicated by arrows from the
wall, ceiling, fence or other obstacles.
H
600
600
Top view
(unit: mm)
Front view
Front
Inspection hole
(600X600)
Control box
1
0
0
0
More than
30cm
More than
30cm
More than
70cm
Fen
ce o
r
obs
tacle
s
Sun
roo
f
Page of 39
Display

LG LB-F3060HL / LB-F3060CL Service Manual ▷ Download

  • DOWNLOAD LG LB-F3060HL / LB-F3060CL Service Manual ↓ Size: 1.07 MB | Pages: 39 in PDF or view online for FREE
  • Here you can View online or download the Service Manual for the LG LB-F3060HL / LB-F3060CL in PDF for free, which will help you to disassemble, recover, fix and repair LG LB-F3060HL / LB-F3060CL Air Conditioner. Information contained in LG LB-F3060HL / LB-F3060CL Service Manual (repair manual) includes:
  • Disassembly, troubleshooting, maintenance, adjustment, installation and setup instructions.
  • Schematics, Circuit, Wiring and Block diagrams.
  • Printed wiring boards (PWB) and printed circuit boards (PCB).
  • Exploded View and Parts List.