INF-12
5-2. Adjust Menu
NOTE 1: It isn't possible to do the setting of the item of DEFFECT COMP", "TEST PATTERN", "VTR DEBUG" and
"DEBUG INF". This is for factory use only.
NOTE 2: The Adjust menu screen can not be shifted to Page 2 in the CAMERA mode.
The menu screen can be shifted to Page 2, when connecting EVR tools in the VCR mode and making
VTR_TEST SW of the measurement board set to L position.
VTR_TEST SW of the measurement board set to L position.
5-2-1. Connection of EVR tools
< Required Tools >
NAME Part
Number
Pcs.
Remark
Measuring Board
VFK1308P
1
EVR Connector Board
VFK1309A
1
NOTE: VFK1309 also can be use
Connection Adapter
VFK1763
1
60 to 30pin
30pin Flat Cable
VFK1317
2
Connect the EVR tools as follows.
1. Unscrew 2 screws and remove the EVR cover.
ADJUST MENU
ATF GAIN ------------YES
LINEARITY ------------YES
Y LEVEL A1
C LEVEL 6B
DEFECT COMP 0
TEST PATTERN OFF
VTR DEBUG 0
DEBUG INF OFF
PRESS MENU TO EXIT
Setting item for LISTA Measurement
Setting item for VIDEO OUTPUT Level
VTR Debug Information
White Blemish Compensation
Setting item for CAMERA Debug Information
display ON/OFF
display ON/OFF
Setting item for TEST PATTERN signal
RESET MENU
THREADING RESET
TAPE RUN RESET
CYLINDER RESET
AUTO OFF LOG RESET
AUTO OFF & HOUR RESET
CAUTION !
USE FACTORY ONLY
PRESS MENU TO EXIT
The individual reset of the Hour Meter
Reset of AUTO OFF LOG
(Page 2)
(Page 1)
The individual reset of the Hour Meter and AUTO OFF LOG
EVR Cover
SCREWS
INF-13
2. Connect the 2 pcs. of 30 pin flat cables (VFK1317) between P101/P102 on the Measuring Board (VFK1308P),
and 2 connectors on the EVR Connector Board (VFK1309A). Make sure that the contact surface of 2 pcs. of 30
pin Flat Cables are inner side and direction of the EVR Connector Board is as shown in Figure. Then connect
the Connection Adapter (VFK1763).
pin Flat Cables are inner side and direction of the EVR Connector Board is as shown in Figure. Then connect
the Connection Adapter (VFK1763).
3. Connect the Connection Adapter (VFK1763) to EVR connector in Unit. Then make sure that the direction of the
VFK1309A and VFK1763 are correct as shown in Figure.
5-2-2. Setting item for LISTA Measurement (Only VCR mode)
ATF GAIN
To confirm the ATF sensitivity, change the tape speed.
By pressing MULTI-DIAL button, enter the adjustment mode and then exit the menu once. The VTR mode is
operated when the menu mode is exited temporarily. The screen below is displayed.
NOW SERVO ADJUST
PUSH MENU TO RETURN
It will be returned to ADJUST MENU when the MENU key is pressed in this condition.
LINEARITY
To confirm the LINEARITY, change the ATF sensitivity.
By pressing MULTI-DIAL button, enter the adjustment mode and then exit the menu once. The VTR mode is
operated when the menu mode is exited temporarily. The screen below is displayed.
NOW SERVO ADJUST
PUSH MENU TO RETURN
It will be returned to ADJUST MENU when the MENU key is pressed in this condition.
NOTE: ATF GAIN and LINEARITY can not be selected on CAMERA mode.
Connect VFK1763 with VFK1309A as
shown in picture.
If the connector is attached backward,
it will not work.
shown in picture.
If the connector is attached backward,
it will not work.
VFK1763
VFK1309A
Part side
30 pin Flat Cable
VFK1308P
Connect the
VFK1763
VFK1763
When the VFK1763 is connected
to EVR connector, be careful of
the direction of VFK1309A.
Please follow as shown in the
figure.
to EVR connector, be careful of
the direction of VFK1309A.
Please follow as shown in the
figure.
INF-14
5-2-3. Adjustment item for Video Level
Y LEVEL
Y level of AV OUT and S-VIDEO OUTPUT signal can be adjusted on this item.
The displayed value is the same as value for Luminance level adjustment in EVR adjustment.
C LEVEL
C level of AV OUT and S-VIDEO OUTPUT signal can be adjusted on this item.
The displayed value is the same as value for Chroma level adjustment in EVR adjustment.
5-2-4. Hour Meter Reset and LOG Clear(Only VCR mode)
The Hour Meter and Auto Off Log data can be reset by items on page 2 in Adjust menu screen. To shift page 2
screen, connect the EVR tools and set VTR_TEST SW of the measurement board to L position follow the item
“5-2-1. Connection of EVR Tools”.
THREADING RESET
It resets the threading number of times.
TAPE RUN RESET
It resets tape running time.
CYLINDER RESET
It resets cylinder rotating time.
< How to reset Hour Meter >
1. The following message is displayed when choosing the item to reset with MULTI-DIAL and pushing MULTI-DIAL.
2. Select YES and when pushing MULTI-DIAL, reset is executed and the following message is displayed.
CYLINDER RESET
EXECUTE ?
NO PUSH JOG
NO PUSH JOG
YES
(In case select the item CYLINDER)
CYLINDER RESET
INITIAL
COMPLETED !
INF-15
AUTO OFF LOG RESET
It resets auto off log information.
< How to reset Auto Off Log >
1. The following message is displayed when choosing the item “AUTO OFF LOG RESET” and pushing
MULTI-DIAL.
2. Select YES and when pushing MULTI-DIAL, reset is executed and the following message is displayed.
AUTO OFF & HOUR METER RESET
It resets auto off log information and hour meter at the same time.
The procedure of resetting is same as the item auto off log and the hour meter.
AUTO OFF CLEAR
EXECUTE ?
NO PUSH JOG
NO PUSH JOG
YES
AUTO OFF CLEAR
INITIAL
COMPLETED !