DIS-11
SECTION 2 DISASSEMBLY PROCEDURES
2.9. Top panel duct assy removal
1. Remove 2 screws-A and remove the earth_metal1, 
   earth_metal2,earth_metal3 and lens shift_earth_metal.
2. Remove 1 screw-B and remove the [M2]-P.C.Board.
3. Remove 2 screws-C and 2 screws-D and remove the top panel duct assy.
A
XYC3+FG10FJK
B
C
SFPDN308R0SV-
D
SFPDN30140SV-
A
A A
A
A A
B
2.10. Intake fan removal
1. Remove 6 screws-A and remove the intake fan1,intake
   fan2,intake fan3 and intake fan4.
2. Remove 1 screw-B and remove the [M1]-P.C.Board.
A
SFPDN30140SV-
B
SFPDN308R0SV-
Intake fan2
Intake fan3
Intake fan4
Intake fan1
[M1]-P.C.Board
A
B
A
C
C
D
D
Earth_metal3
Earth_metal2
Earth_metal1
Top_panel_duct_assy
Lens shift_earth_metal
[M2]-P.C.Board
DIS-12
SECTION 2 DISASSEMBLY PROCEDURES
3. Optical Parts Disassembly
3.1. Disassembly flow chart
Completed Product
3.2.4. Lens shift unit disassembly
3.2.3. Polarizer-out replacement
3.2.2. Optical block mounting (only for VW535N/VX605N)
3.2.1 Optical block removal (only for VW535N/VX605N)
2.7. Lighting assy removal
3.3 Polarizer-in removel
3.4. Condenser lens-out removal
3.5. PBS and Integrators removal
3.6. Lighting case top removal
3.7. Parts location and direction in the lighting case
3.2. Projection lens and optical block assy removal
2.5. [A]-P.C.Board unit removal
2.4. Top cover unit removal
DIS-13
SECTION 2 DISASSEMBLY PROCEDURES
Important notice on optical block replacement
 LCD panels used for this model cannot be replaced separately. Do not disassemble the optical block. These LCD panels 
are installed with precision at the factory. When replacing the LCD panel, should be replaced whole of the LCD panels and 
prism assy at once. 
When replacing optical block, take the optical and electrical adjustments following to the chapter "Adjustment".
Note for model PT-VZ575N
Do not remove the optical block from the 
base mounter of the projection lens, doing 
so may cause degradation of focus per-
formance.
3.2. Projection lens and optical block assy removal
 <note> Before removing the projection lens and optical block assy, take out the lighting case from the bottom case.
1. Remove 4 screws-A and remove the projection lens and optical block assy from the lighting case.
3.2.1 Optical block removal (only for PT-VW535N/VX605N)
1. Loosen 4 hex screws-A and remove the optical block upward.
 <note> When taking the cleaning or replacing the polarizers, we recommend not to remove the 
 optical block from the projection lens.
A
A
A
A
Lighting case
projection lens and optical block assy
Optical block
Projection lens
A
SBXAA257R8SAA
A
DIS-14
SECTION 2 DISASSEMBLY PROCEDURES
Polarizer OUT(G)
(Inorganic type)
Polarizer OUT(R)
(Inorganic type)
AL evaporated side
(In-coming side)
AL evaporated side
(In-coming side)
Polarizer OUT(B)
(Inorganic type)
AL evaporated side
(In-coming side)
Green marker (behind)
Red marker
Blue marker (behind)
1. Remove each polarizer. As the polarizers are attached with adhesive tape, remove them carefully.
<Note> When replacing, pay attention not to scratch or break the surrounding parts (Prism , LCD panel, etc.). As the part
of LCD panels are adjusted preciously at the factory, handle the optical block not to apply any power force on it.  
We recommend that the projection lens should be mounted on the optical block while taking the replacement.
  •  Insert the edge of flat screw driver into the adhesive part of the polarizer and remove it bit by bit by turning the driver.  
(See below figure)
3.2.3. Polarizer-out replacement
Before replacing the polarizer, refer to "Note on handling of inorganic polarizer" on item 4. optical parts cleaning.
Polarizer OUT(G)
Flat screw driver
3.2.2 Optical block mounting (only for VW535N/VX605N)
1. Mount the optical block onto the base mount as shown in the figure.
2.       Gently press bottom part of the optical block in the arrow direction and fix it by tighten 4 hex-screws in the numerical order 
in the figure. 
m
j
k
l
Base mount
Optical block