DIS-19
SECTION 2 DISASSEMBLY PROCEDURES
Relay lens(IN)
Relay lens(IN)
Relay lens(OUT)*
Dichroic mirror (G)
Dichroic mirror B
Mirror (R)
Mirror (B)*
Condenser lens (G/B)
Mirror (R)
Coated side comes 
reflection side
Coated side comes 
reflection side
Marking comes this 
side up
Marking comes this 
side up
3.7. Parts location and direction in the lighting case
When mounting or assembling the parts in the lighting case, the parts must be mounted in the speci-
fied location and direction as shown in the figure below.
Note:  The parts indicated with (*) are mounted by adhesive, therefore, they cannot be replaced 
individually.
Condenser lens (G/B)
DIS-20
SECTION 2 DISASSEMBLY PROCEDURES
<Cable reforming>
Reform the cables as shown in the figure below. Place the cables at the original
position after replacing the parts.
Ferrite core
K9B
K8L
K8G
K9A
K8D
K9D
K8H
K8I
K9G
K8000
K9C
K9E
K8E
K9F
K8R
Connector
Connect to
K9B
Intake fan2
K8L
Intake temp. sensor [M1]-P.C.B
K8G
Air flow sensor [M2]-P.C.B
K9A
Intake fan1
K8D
RC [R]-P.C.B
K9D
Intake fan4
K8H
Lamp ballast [B]-P.C.B
K8I
Lamp connect [C]-P.C.B
Connector
Connect to
K9G
Power fan
K8R (Behind)
Power [P]-P.C.B
K8000
Iris unit
K9C
Intake fan3
K9E (Behind)
Lamp fan
K9F
Exhaust fan
K8E (Behind)
Exaust temp. sensor [M3]-P.C.B
DIS-21
SECTION 2 DISASSEMBLY PROCEDURES
Screen side
Lamp side
In-coming 
side
In-coming side
Out-going side
2.0mm
2.0mm
2.0mm
2.0mm
2.0mm
2.0mm
Contact prohibition area
Aluminum evaporated surface
4. Cleaning of Optical Parts
4.1. Note on handling of inorganic polarizer
This projector provides high durable inorganic polarizer which has a rib shaped evaporated aluminum on the glass surface. 
This surface is very delicate. If touching or wiping the surface, the polarizing function will be lost due to damage of the alu-
minium rib construction on the surface. Extreme care should be taken to handle the polarizer.
 Inorganic polarizer handling
Never grasp the surface or edges of the polarizer with bare hand. If fat and oil on your hand adheres on the edges 
of polarizer, the linear bolt may appear on the glass surface due to capillarity. Grasp the edges of the glass with 
new gloves or with tweezers when handling it.
 Inorganic polarizer cleaning
When removing the dust on the surface, use a commercial (inert gas) air spray or air blower to remove them. 
Never use organic solvents.
 Indication of light in-coming side and out-going side
The indication of "in-coming side" and "out-going side" of the polarizer or LCD panels is shown in the figure. It indicates the 
light in-coming and out-going from the lamp.
 Contact prohibition area of inorganic polarizer
The aluminum evaporated  surface of inorganic polarizer is contact prohibition area. Prohibit touching it with bare hand, wip-
ing or contacting with the other parts.
DIS-22
SECTION 2 DISASSEMBLY PROCEDURES
The optical block cannot be disassembled.
The optical block is composed of very sensitive parts. There are some parts to bring on the performance down by touching or 
wiping the surface of parts. Carry out the cleaning according to the cleaning guide table below.
The optical block has been adjusted preciously at the factory. Do not apply strong force to the LCD panel or frame on the 
block.
Type
Air blower 
cleaning
Wipe cleaning
Alcohol cleaning
Parts name
Type
in-coming side
out-going side
LCD panel
--
4
4
4
 *
*
Polarizer OUT(R)
Inorganic
4
NG
4
NG
Polarizer OUT(G)
Inorganic
4
NG
4
NG
Polarizer OUT(B)
Inorganic
4
NG
4
NG
Optical filter (R)
Optical filter (G)
Optical filter (B)
--
4
4
-
4
 *
Optical filter (R)
Optical filter (B)
Polarizer OUT(G)
(Inorganic)
Polarizer OUT(R)
(Inorganic)
Polarizer OUT(B)
(Inorganic)
Optical filter (G)
R-LCD Panel
B-LCD Panel
G-LCD Panel
4  
Cleaning OK
*  When taking the wipe cleaning or alcohol cleaning, please pay special attention not to 
touch the surface of inorganic polarizers.
Top view of the optical block
4.2. Cleaning the internal parts of the optical block