Panasonic PT-VW355N / PT-VW355ND / T-VW355NT / PT-VX425N / PT-VX425ND / PT-VX425NT (serv.man2) Service Manual ▷ View online
INF-17
SECTION 1 SERVICE INFORMATION
4. 3. 5. Air filter maintenance
Perform maintenance of the air filter in the following case.
• The air filter is clogged with dust, causing the filter replacement message to appear on the screen.
• The air filter is clogged with dust, causing the filter replacement message to appear on the screen.
Attention
• Make sure to turn off the power before performing maintenance on the air filter unit.
• Make sure that the projector is stable, and perform the maintenance in a safe place where the unit will not be damaged even
• Make sure that the projector is stable, and perform the maintenance in a safe place where the unit will not be damaged even
if you drop the air filter unit.
4. 3. 6. Replacement procedure for air filter unit
1) Remove the air filter cover. (Fig. 1)
• Open the air filter cover in the direction of the arrow and remove it.
2) Remove the air filter unit. (Fig.2)
• Hold the tab of the air filter unit and pull out in the direction of the arrow.
• After removing the air filter unit, remove foreign objects and dust from the air filter compartment and the projector’s air
• Open the air filter cover in the direction of the arrow and remove it.
2) Remove the air filter unit. (Fig.2)
• Hold the tab of the air filter unit and pull out in the direction of the arrow.
• After removing the air filter unit, remove foreign objects and dust from the air filter compartment and the projector’s air
intake port if there are any.
3) Attach the unused air filter unit to the projector (Fig.3)
• Hold the air filter unit that the tab is in up-left side in the figure, put the right side in the figure first, and press the tab side
• Hold the air filter unit that the tab is in up-left side in the figure, put the right side in the figure first, and press the tab side
until make a click sound.
• Please press the tab of the air filter unit other than the pleated filter during installation.
4) Install the air filter cover.
• Perform Step 1) in “Removing the air filter unit” in the reverse order to close the air filter cover and press
it firmly until make a click sound.
• Make sure that the air filter cover is closed tightly.
4) Install the air filter cover.
• Perform Step 1) in “Removing the air filter unit” in the reverse order to close the air filter cover and press
it firmly until make a click sound.
• Make sure that the air filter cover is closed tightly.
Air filter cover
Fig. 1
Air filter unit
Tab
Tab
Fig. 2
Fig. 3
Attention
• Turn off the power before you replace the air filter unit.
• When attaching the air filter unit, make sure that the projector is stable, and work in an environment that is safe, even in the
• When attaching the air filter unit, make sure that the projector is stable, and work in an environment that is safe, even in the
event of the air filter unit dropping.
• Make sure that the air filter unit is properly attached before using the projector. If it is not attached, the projector will suck in
dirt and dust causing a malfunction.
• Do not put anything into the air vents. Doing so may result in malfunction of the projector.
• The air filter unit to be replaced should be an unused product.
• After replacing the air filter, reset the filter counter. Otherwise, “FILTER COUNTER has reached the set time.” will appear on
• The air filter unit to be replaced should be an unused product.
• After replacing the air filter, reset the filter counter. Otherwise, “FILTER COUNTER has reached the set time.” will appear on
screen.
Note
• The replacement cycle of the air filter unit varies greatly depending on the usage environment.
INF-18
SECTION 1 SERVICE INFORMATION
5. Troubleshooting
5. 1. Shutdown system
This projector provides the shutdown function to set into the standby mode immediately for product safety when the projector
has the fan operation error or lamp lightning error.
has the fan operation error or lamp lightning error.
LED indication status
Shutdown detection
Probable cause
OSD warning
Not lighting or flashing
Power supply block
Fuse : Rated 6.3A
Fuse : Rated 6.3A
Blown out of fuse (with another reason)
Disconnecting the connectors
Power board failure
Ballast board failure
Disconnecting the connectors
Power board failure
Ballast board failure
-
Thermal fuse
⇒ Over 113ºC
Blown out of thermal fuse (with another reason)
Check usage environment
Disconnecting the thermal fuse
Check usage environment
Disconnecting the thermal fuse
-
Sub-microprocessor communication error
Sub-microprocessor failure
Disconnection the communication lines
Disconnection the communication lines
-
LAMP LED lights
Lamp runtime
⇒ More than 5000 hours
(Shutdown in 10 minutes)
Lamp runtime is over
“REPLACE LAMP IN ** MIN-
UTES, POWER WILL TURN OFF
AND GO INTO STANDBY
UTES, POWER WILL TURN OFF
AND GO INTO STANDBY
MODE
AUTOMATICALLY.”
LAMP LED brinks
(0.5 seconds cycle)
(0.5 seconds cycle)
Lamp igniting error/Lamp goes off
Lamp cover not installed
Disconnecting the connectors
Lamp error/burning
Ballast block error
Disconnecting the connectors
Lamp error/burning
Ballast block error
-
WARNING LED lights
Temperature exceeds a threshold (*1)
Temperature error
-
Sum of the fan voltage level and filter
clogged level (*2)
clogged level (*2)
Filter clogged
-
WARNING LED blinks
(2 seconds cycle)
(2 seconds cycle)
No fan sense signal
Each fan sense signal level
Each fan sense signal level
⇒ The signal is less than 50% of target
level for more than 5 seconds
Disconnecting the connectors
Fan rotation error/ abnormal
Fan control circuit on the main bard has error.
Fan rotation error/ abnormal
Fan control circuit on the main bard has error.
-
Power supply error
Disconnecting the connectors
Board error
Board error
-
*1 It depends on the lamp mode , fan mode or installed environment.
*2 It depends on the various levels of the filter clogged and fan voltage.
*2 It depends on the various levels of the filter clogged and fan voltage.
The count down number 10 to 1
will be indicated in **.
will be indicated in **.
INF-19
SECTION 1 SERVICE INFORMATION
5. 2. Troubleshooting
* The letters in the left of inspection items indicate the P.C. Boards related to their respective descriptions.
* Please check items with the interlock switch on.
* Please check items with the interlock switch on.
■ Power does not turn ON. ([ON(G)/STANDBY(R)] LED does not light in red)
Check the connection of each connector
AC inlet, K6B - K602, K6R - K8R
NG
Connect the cables properly
A
Disconnect the connectors [K8R]. Check the short circuit
between pins (5)-(6), (10)-(11) of connector [K8R].
NG
A
Replace the [A] P.C.Board
P
Check and replace the [P] P.C.Board
OK
OK
INF-20
SECTION 1 SERVICE INFORMATION
■ Lamp does not turn ON.
Confirm the connection of each connector on A-P.C
Board and lamp.
Confirm the lamp fixing screws.
NG
Connect the cables properly
Confirm the lamp condition
NG
Replace the lamp
Is each thermal sensor operating in normal?
NG
Check each thermal sensor and connection
A
Confirm that the short circuit between terminals (K6D_1A) and
(K6D_2A). (DC 380V is observed in normal)
(K6D_2A). (DC 380V is observed in normal)
NG
A
Check or replace [P] P.C.Board
Is each fan rotating when the projector turns on?
NG
Check each fan and connection
A
Confirm that the voltage at pin (2) of connector [K8R] changes
from Low to Hi when the power is ON.
from Low to Hi when the power is ON.
NG
A
Check or replace [A] P.C.Board
A
Confirm that the voltage at pin (1) of connector [K8R] changes
from Low to Hi when the power is ON.
from Low to Hi when the power is ON.
NG
A
Check or replace [A] P.C.Board
OK
OK
OK
OK
OK
OK
OK
BQ Replace [BQ] P.C.Board
BQ
Confirm the voltages between pins of connector [CN1] below;
(1) - (3) DC 380V ± 20V
(3) - (4) DC 16.5V ± 1.6V
NG
BQ Check the cable [ZK6D].
P
Confirm that the short circuit between terminals (K6D_3A) and
(K6D_2A). (DC 16.5V is observed in normal)
(K6D_2A). (DC 16.5V is observed in normal)
NG
P
Check or replace [P] P.C.Board
OK
OK
Click on the first or last page to see other PT-VW355N / PT-VW355ND / T-VW355NT / PT-VX425N / PT-VX425ND / PT-VX425NT (serv.man2) service manuals if exist.