SECTION 1  SERVICE  INFORMATION
< RZ670/RW630 >
  5. 2. Service
    5. 2. 1. Supporting Methods
The basic service policy is shown below.
PC-P.C.Board (Specified components are replaced)
D-P.C.Board
DMD block (Specified components are replaced)
Lens unit
LD unit
Rod ASSY
    5. 2. 2. Jig and Tool
1. Hexalobe (TORX type) driver [2.72 mm]
VESSEL T10H or comparable product
Part No. : TZSH07035
2. Hexalobe (TORX type) driver [3.94 mm]
VESSEL T20H or comparable product
Part No. : TZSH07042
3. Hex wrench  [2.5 mm]
Use the Hex wrench on the commercially available.
4. Laser safety glass
Please wear glasses for safety when checking with the cover removed.
Type : Full absorption, Adaptation laser : Ar, Wavelength : 448 - 462nm
Part No. : TZSH07038  (or comparable product)
    5. 2. 3. Repair
1. Energization check and adjustment, after assembling the lighting block completely.
Before turning on the power, please make sure that the lighting block is completely assembled.
The service engineer who works on this model and also other people who are in the same room need
to wear the laser safety glasses for avoiding the laser irradiation just in case.
2. Before repair, make sure to turn off the main power and unplug the power cord from the power outlet.
* When replacing the print board, the internal electrical parts can be broken by the static electricity of clothes or
  human body. Be careful of static electricity and wear the anti-static electricity gloves.
3. After repairing, please check the gradation (10step or the gray scale) test pattern or moving image. 
    Also, please check that it is ormal on a self check screen.
4. Do handling and safekeeping carefully because the user setup information remains in the projector.
    5. 2. 4. Replacement of A-P.C. board
1. When the replacement of A-P.C.Board (assembly) is needed, back up the memory information such as adjustment data
    from the old board to PC with the service soft. Then transfer this data to the new A-P.C.Board.
    For more information refer to the SECTION 3 "Adjustment".
2. If you cannot transfer the data that uses the service software, remove [ IC3711 ] from the original board and mount
    them on the new board.
3. When A-P.C.Board is replaced, the MAC address of wired LAN will be changed. Explain it to the customers in advance.
Applied parts
        Other electrical parts and mechanism parts
Repair contents
  Block replacement
  P.C.Board replacement
  Replaced by discrete components
INF - 21
SECTION 1  SERVICE  INFORMATION
< RZ670/RW630 >
6. Troubleshooting
  6. 1. Shutdown system
Indicator indication
STANDBY/ON
Red lights
TEMP
Red lights
Not lighting or flashing
Blown out of the fuse
( with some reason )
Main microcomputer boot process error
Air intake port clogging
Something wrong with power
block
DMD temperature sensor bad connection
Connector (DG4/FM2) disconnecting
Temperature sensor failure
Connector disconnection
Cooling pump rotation failure
Power fuse <K-P.C.B>
  ⇒12A
DMD temperature sensor
  ⇒ Below -20 ℃
Each FAN sense signal
 ⇒
No signal
Power circuit Thermal protector
  ⇒(CF9000,CF9001): 115±15℃
Probable cause
Intake air temperature sensor bad
connection
Connector (M11/DG18) disconnecting
Temperature sensor failure
FPGA initialized or communication error
Signal processing unit circuit failure
OSD warning, etc
Intake air temperature sensor
  ⇒ Below -20 ℃
Main software activation error
Shutdown detection
Connector disconnection
Fan rotation failure
LD2 temperature sensor bad connection
Connector (RT12/RT1) disconnecting
STANDBY/ON
Blinks red 3 times
Fan rotation failure
Life time of the fan
Trimming wheel rotation speed
 ⇒
 Under 100Hz
Rotation problem with Trimming wheel
Phosphor1 wheel rotation speed
 ⇒
 Under 100Hz
Rotation problem with Phosphor1 wheel
Formatter Initialization error
DG printed circuit board failure
Cable connection failure
Connector contact failure
Phosphor2 wheel rotation speed
 ⇒
 Under 100Hz
Rotation problem with Phosphor2 wheel
TEMP
Blinks red 3 times
Each fan sense signal
 ⇒
Slower than 70% of target
  
 for more than 5 sec.
LD2 temperature sensor
  ⇒ Below -20 ℃
Each cooling pump sense signal
 ⇒
No signal
Exhaust air temperature sensor
  ⇒ Below -20 ℃
Exhaust air temperature sensor bad
connection (M11/BR4)
Temperature sensor failure
LD1 temperature sensor
  ⇒ Below -20 ℃
LD1 temperature sensor bad connection
Connector (DR6) disconnecting
Each cooling pump sense signal
 ⇒
Slower than 70% of target
  
 for more than 5 sec.
cooling pump rotation failure
Life time of the cooling pump
INF - 2
2
SECTION 1  SERVICE  INFORMATION
< RZ670/RW630 >
*1 :
 
 
LD driver circuit (D/DR) abnormality,
LD unit abnormality
LD2 temperature sensor
  ⇒ More than 80 ℃
DMD temperature sensor
 ⇒
After power-on, Is below
  
 5 ℃ for more than 5 min.
High temperature of environment
Air intake ports  are blocked
Intake air temperature sensor abnormality
Abnormal installation of heatsink
Ventilation holes are blocked
At highlands, high altitude mode is not set
OSD warning, etc
Exhaust air temperature sensor
  ⇒ More than 65 ℃
LD1 temperature sensor
  ⇒ More than 80 ℃
LIGHT
Blinks red 2 times
Lamps memory (EEPROM) communication
 ⇒
No response
 ⇒
Noncompliant lamp info
LD status
 ⇒
All LD units are off, during the status
      other than normal operation
Coolant is insufficient or the deterioration
of the cooling pump,
Clogging of the radiator
At highlands, high altitude mode is not set
78℃⇒“U16  LD1 unit
temp. warning“ *1
76℃⇒Error cancel
Exhaust fan is deterioration, abnormal
Ventilation holes are blocked
At highlands, high altitude mode is not set
63℃⇒ “U13  Exhaust air
temp. warning“ *1
61℃⇒Error cancel
Usage environment temperature is lower
than the rated
Lamp is not installed
Lamp memory cable bad contact or
disconnecting
Other models lamp installed
TEMP
Blinks red 2 times
LIGHT
Blinks red 3 times
Coolant is insufficient or the deterioration
of the cooling pump,
Clogging of the radiator
At highlands, high altitude mode is not set
DMD temperature sensor
  ⇒ More than 75 ℃
Intake air temperature sensor
  ⇒ 48℃ or more
Display of error information in status menu.
When ERROR OSD of service mode is set to [ON].
46℃⇒ “U11  Intake air
temp. warning“ *1
44℃⇒Error cancel
73℃⇒ “U12  Optical
module temp. warning“ *1
71℃⇒Error cancel
78℃⇒“U17  LD2 unit
temp. warning“ *1
76℃⇒Error cancel
LD1:“FL1  LD1 unit error“
LD2:“FL2  LD2 unit error“
Light source1 abnormality
   “FA8  LD1 error“  *1
Light source2 bnormality
   “FC8  LD2 error“ *1
Indicator indication
Shutdown detection
Probable cause
INF - 2
3
SECTION 1  SERVICE  INFORMATION
< RZ670/RW630 >
*1 :
 
 
LD driver circuit (D/DR) abnormality,
LD unit abnormality
LD2 temperature sensor
  ⇒ More than 80 ℃
DMD temperature sensor
 ⇒
After power-on, Is below
  
 5 ℃ for more than 5 min.
High temperature of environment
Air intake ports  are blocked
Intake air temperature sensor abnormality
Abnormal installation of heatsink
Ventilation holes are blocked
At highlands, high altitude mode is not set
OSD warning, etc
Exhaust air temperature sensor
  ⇒ More than 65 ℃
LD1 temperature sensor
  ⇒ More than 80 ℃
LIGHT
Blinks red 2 times
Lamps memory (EEPROM) communication
 ⇒
No response
 ⇒
Noncompliant lamp info
LD status
 ⇒
All LD units are off, during the status
      other than normal operation
Coolant is insufficient or the deterioration
of the cooling pump,
Clogging of the radiator
At highlands, high altitude mode is not set
78℃⇒“U16  LD1 unit
temp. warning“ *1
76℃⇒Error cancel
Exhaust fan is deterioration, abnormal
Ventilation holes are blocked
At highlands, high altitude mode is not set
63℃⇒ “U13  Exhaust air
temp. warning“ *1
61℃⇒Error cancel
Usage environment temperature is lower
than the rated
Lamp is not installed
Lamp memory cable bad contact or
disconnecting
Other models lamp installed
TEMP
Blinks red 2 times
LIGHT
Blinks red 3 times
Coolant is insufficient or the deterioration
of the cooling pump,
Clogging of the radiator
At highlands, high altitude mode is not set
DMD temperature sensor
  ⇒ More than 75 ℃
Intake air temperature sensor
  ⇒ 48℃ or more
Display of error information in status menu.
When ERROR OSD of service mode is set to [ON].
46℃⇒ “U11  Intake air
temp. warning“ *1
44℃⇒Error cancel
73℃⇒ “U12  Optical
module temp. warning“ *1
71℃⇒Error cancel
78℃⇒“U17  LD2 unit
temp. warning“ *1
76℃⇒Error cancel
LD1:“FL1  LD1 unit error“
LD2:“FL2  LD2 unit error“
Light source1 abnormality
   “FA8  LD1 error“  *1
Light source2 bnormality
   “FC8  LD2 error“ *1
Indicator indication
Shutdown detection
Probable cause
INF - 2
3
Page of 23
Display