DOWNLOAD Panasonic PT-RZ570 (serv.man4) Service Manual ↓ Size: 30.41 MB | Pages: 99 in PDF or view online for FREE

Model
PT-RZ570 (serv.man4)
Pages
99
Size
30.41 MB
Type
PDF
Document
Service Manual
Brand
Device
Projector / 1-CHIP DLP BASED PROJECTOR
File
pt-rz570-sm4.pdf
Date

Panasonic PT-RZ570 (serv.man4) Service Manual ▷ View online

INF-20
SECTION 1 SERVICE INFORMATION
< RZ570 >
5. 1. 2. Light source/temperature indicators
  • If a problem occurs inside the projector, the light source indicator <LIGHT> or the temperature indicator <TEMP> will inform 
you by lighting or blinking.
Light source indicator <LIGHT>
Indicator status
Lighting in red
Blinking in red
(2 times)
Blinking in red
(3 times)
Status
Some of the elements of the light 
source are defective and the light 
output has decreased.
The light source does not light up, or the light source turns off while the 
projector is in use.
Cause
Solution
f
  Turn the <MAIN POWER> switch to <OFF> , and turn on the power again.
Note
f
  The light source indicator <LIGHT> lights in green while the projector is in projection mode if there is no notification by lighting or blinking in 
red.
Temperature indicator <TEMP>
Indicator status
Lighting in red
Blinking in red
(2 times)
Blinking in red
(3 times)
Status
Warm-up status
Internal temperature is high 
(warning).
Internal temperature is high 
(standby status).
The cooling fan has 
stopped.
Cause
f
  Did you turn on the power 
when the temperature 
was low (around 0 °C 
(32 °F))?
f
  Is the air intake/exhaust port blocked?
f
  Is the room temperature high?
Solution
f
  Wait at least five minutes
in the current status.
f
  Use the projector 
in an appropriate 
operating environment 
temperature
*1
.
f
  Remove any objects that are blocking the air intake/
exhaust port.
f
  Use the projector in an appropriate operating 
environment temperature
*1
.
f
  Do not use the projector at an altitude of 4 200 m 
(13 780') or higher above sea level
*2
.
f
  Repair 
*1 The operating environment temperature of the projector differs depending on the altitude or the setting of the [PROJECTOR SETUP] menu → [ECO
     MANAGEMENT] → [OPERATING MODE]. Refer to “Operating environment temperature” for details.
*2 When the [PROJECTOR SETUP] menu → [ECO MANAGEMENT] → [OPERATING MODE] is set to [ECO] or [SILENT], the projector cannot be
used at an altitude of 2 700 m (8 858') or higher above sea level.
INF-21
SECTION 1 SERVICE INFORMATION
< RZ570 >
5. 2. Shutdown system
•   This projector provides the shutdown function to set into the standby mode immediately for product safety when the projector    
has the fan operation error or lightning error. 
Indicator status
Self-test
display
Shutdown detection
Probable cause
OSD warning, others
Not lighting or flashing
Power circuit (P-P.C.Board)
Fuse (F9100) : Rated 10A
Blown out of fuse
(with another reason)
STANDBY/ON blinks
3 times in red
F90/F91/F92 FPGA config error or communication 
error
Failure on signal processing part
Main software boot error
Main microprocessor rewrite error
F97/F98
Formatter initializing error (A97)
Formatter status error (A98)
A-P.C.Board failure. 
FH0/FH1
Phosphor wheel rotation speed
Detected by Main CPU (FH0)
Detected by FPGA (FH1)
 a
 Under 60Hz
*  Shutdown if the 60 msec (3 times by 
30 msec) NG is detected before turn-
ing on the light at power-on.
Connector contact failure
Phosphor wheel or drive circuit failure
C2-P.C.Board failure 
F85/F86
Color wheel rotation speed
Detected by Main CPU (F85)
Detected by FPGA (F86)
 a
 Under 60Hz
*  Shutdown if the 60 msec (3 times by 
30 msec) NG is detected before turn-
ing on the light at power-on.
Connector contact failure
Color wheel or drive circuit failure
C1-P.C.Board failure 
F99
[RZ570BT/RZ570WT only]
AC input voltage
a
  Over AC 160V
Rated voltage NG
STANDBY/ON lights
in red
TEMP lights
H11
Intake air temperature sensor
     a Lower than -20ºC
Intake air temperature sensor error
Connector contact failure or disconnect
H12
Optical module temperature sensor
     a Lower than -20ºC
Optical module temperature sensor error
(FM-P.C.Bosrd)
H13
Exhaust air temperature sensor
     a Lower than -20ºC
Exhaust air temperature sensor error
Connector contact failure or disconnect
H14/H16
LD1/2 units temperature sensor (H14)
LD3/4 units temperature sensor (H16)
     a Lower than -20ºC
Temperature sensor error or disconnect
  LD1/2 : Connector BR11 
  LD3/4 : Connector BR10
TEMP blinks 3 times 
(In Warning: TEMP lights)
FE1~FE7
(F50~F56)
Each FAN sense signal undetectable
     a  Fan rotation signal is not detected 
for more than 5 sec.
Each FAN sense signal  
     a  Fan rotation is lower than 70% of 
target for more than 5 seconds
Connector disconnection
Fan control circuit failure
Fan rotation error, end of life
If one of the fans stops, 
the projector does not 
shut down and reduces 
the LD output power until 
turning off.
If more than two fans have 
an error, the projector shut 
down.
(Warning) Each FAN sense signal  
     a  Fan rotation is lower than 80% of 
target for more than 5 seconds
TEMP blinks 2 times 
(In Warning: TEMP lights)
U21
(U11)
Intake air temperature sensor
     a More than 48ºC *1
Abnormal intake air temperature
  External air temperature is high
  Ventilation holes are blocked
"TEMPERATURE 
WARNING"
U22
(U12)
Optical module temperature sensor
     a More than 75ºC *1
Abnormal optical module temperature
  External air temperature is high
  Ventilation holes are blocked
"TEMPERATURE 
WARNING"
U23
(U13)
Exhaust module temperature sensor
     a More than 65ºC *1
Abnormal exhaust air temperature
  External air temperature is high
  Ventilation holes are blocked
"TEMPERATURE 
WARNING"
U24
(U14)
Optical module temperature sensor
     a  Lower than 8 ºC for more than 5 
min, after power on.
Operating environment temperature is 
too low.
U25/U27
(U16/U18)
LD1/2 units temperature sensor (U25)
LD3/4 units temperature sensor (U27)
     a More than 80ºC *1
Abnormal LD units temperature
  External air temperature is high
  Ventilation holes are blocked
"TEMPERATURE 
WARNING"
INF-22
SECTION 1 SERVICE INFORMATION
< RZ570 >
Indicator status
Self-test
display
Shutdown detection
Probable cause
OSD warning, others
LIGHT blinks 3 times
(In Warning: LIGHT lights)
F61
LD driver communication error
(No response)
Communication line failure between the 
LD driver
FL1
(FL5/FL6
FL7/FL8)
LD driver microprocessor status
     a Abnormality on LD
Light source open failure
LD units deterioration
Lighting failure of the LD units
LD driver circuit is abnormal
"LD*  ERROR"
Shutdown if all of LD have 
an error.
 
 
 
 
*1 :   The threshold values are just reference temperature at operation mode (Normal), floor installed and less
                                                    than 1400m altitude. They are depending on the operating mode and installed condition.
 [Note]
 • 
[SELF TEST] can be checked in the [PROJECTOR SETUP] menu → [STATUS] → [SELF TEST].
 
  Can not checked if projector shutdown.
INF-23
SECTION 1 SERVICE INFORMATION
< RZ570 >
5. 3. System log data acquisition method
* The log data acquisition via LAN terminal or serial terminal.
5. 3. 1. Equipment to be used
1. Computer : Use it for the log data acquisition.
2. Communication cable :
    
 
 
 
 
   
Serial terminal connection
D-sub 9pin (male/female RS-232C straight)
LAN terminal connection
LAN cable. (When connecting directly, use a cross cable)
3. Service Software : [DataLogBackup.exe] Download from the projector service Web (PASS).
5. 3. 2. Connection preparations
1. Check the settings of the projector.
 
Serial terminal connection
  1) The [INPUT SELECT] of sub menu [RS-232C] must be set according to the connection method.
  2) The [EMULATE] of sub menu [RS-232C], please set to [DEFAULT]. (in service mode)
  3) Check the RS-232C settings (ID, Baudrate and Parity) and take a note.
 
 
LAN terminal connection
  1) Check the network IP address of the projector and take a note.
  2) Set the IP address of computer to approximate value of projector IP address.
  3) When connecting using DIGITAL LINK compatible device.
      The [DIGITAL LINK MODE] of sub menu [NETWORK], please set to [AUTO] or [ETHERNET].
   
  [Note]
  •  If you have changed the each menu settings, please return settings of the original (customers) after work.
2. Connect the projector and the PC by using a communication cable.
5. 3. 3. Acquisition of log data
1. Switch the projector to "Normal-Standby" mode (STANDBY/ON indicator is lighting in red).
2. Activate a [DataLogBackup.exe] service software.
Serial terminal connection example
LAN terminal connection example
Projector
SERIAL IN
Communication cable (straight)
Computer
D-Sub 9P
(male)
LAN cable (straight)
LAN cable (straight)
Hub
Projector
LAN
Computer
Page of 99
Display