Panasonic PT-RZ570 (serv.man4) Service Manual ▷ View online
INF-12
SECTION 1 SERVICE INFORMATION
< RZ570 >
6. POWER OFF MESSAGE
• Operation setting of shutter at standby operation.
- SHUTTER KEEP: When pushing the standby key while the shutter mode is on, the projector keeps the shutter mode
on and sets into standby mode.
- SHUTTER OPEN: When pushing the standby key while the shutter mode is on, the projector opens the shutter and
displays the "Power OFF confirmation message". (Default setting)
7. ERROR OSD
• Enables to display the error information of the LIGHT indicators on the screen.
(It is useful when using the projector with rear projection mode)
- ON : "LD1\LD2 ERROR" is displayed on the screen if the lighting error occurs.
(It will disappear when any of the control buttons is pressed.)
- OFF : No message is displayed on the screen if the lighting error occurs. (Default setting)
8. MODEL
• This setting is necessary when the A-P.C. Board is replaced with new one.
* If you can copy EEPROM data from old A-P.C. Board, this setting is unnecessary.
* This model setting is effective after power restart.
9. LIGHT SELECT
• Select the LD to turn on. Press the [ENTER] key to switch.
- ALL : Both of LD1/LD2 turn on (Default)
- BANK1/2 : LD1 and LD2 turns on
- BANK3/4 : LD3 and LD4 turns on
• The selection will be reset to "ALL" after turning off the projector.
10. UNIFORMITY GRID MODE
• Set up the grid resolution for UniformityTool.
- 1 : Grid resolution 8 x 8
- 2 : Grid resolution 32 x 20 (Default)
11. COMMAND CONTROL TIMEOUT
• Set up the communication specifications of the command control.
- 0SEC : 1 Command 1 session mode. (Default)
- 30SEC : Keeps a session for 30 seconds.
3. 3. 2. Additional function of each menu
1. [POSITION] menu
• [DVI/HDMI EQUALIZER] is added to a sub menu.
- When noise contamination to DVI/HDMI input caused by long cable or external device, set this item so that the noise
decreases. (AUTO/LOW/MID/HIGH)
INF-13
SECTION 1 SERVICE INFORMATION
< RZ570 >
2. [DISPLAY OPTION] menu
• [OSD SIZE] is added to the setting of the sub menu [ON-SCREEN DISPLAY].
- Setting the size of on screen display. (DOUBLE/NORMAL)
3. [PROJECTOR SETUP] menu
(1) The following two items are added to the sub-menu.
1) [COOLING CONDITION]
- Fan control can be set manually. (Usually set to [AUTO].)
2) [HIGH ALTITUDE MODE]
- Altitude can be set manually. (Usually set to [AUTO].)
(2) In the [BRIGHTNESS CONTROL STATUS] sub menu, [DETAILED INFORMATION] is displayed by pressing the [ENTER]
key.
- The detailed information of brightness control can be checked.
INF-14
SECTION 1 SERVICE INFORMATION
< RZ570 >
(3) [EMULATE] is added in sub menu [RS-232C].
- The following choices will be added. (Default setting : DEFAULT)
MODE_HI / MODE_NE / MODE_EP / MODE_SA / MODE_SH /
MODE_MI / MODE_SO / MODE_CH / OTHER
(4) The following items are added to the sub menu [STATUS].
1) Page 2
- VERTICAL TILT
Vertical angle
- HORIZONTAL TILT
Horizontal angle
2) Page 3
- DIGITAL LINK VERSION
Digital LINK software version
- FPGA VERSION
FPGA software version (FPGA1/FPGA2)
- DDP VERSION
Formatter software version
- LD DRIVER VERSION
LD Driver software version (LD1/LD2)
- EMULATE
Status of EMULATE setting
- VERSION
EMULATE version
3) Page 5
- MAIN VER.
Main microprocessor software version
- FPGA VER.
FPGA software version (FPGA1/FPGA2)
- BMP
Bitmap data version
- ENG ~ CC.
Version of the each font data
(English/Russian/Korean/Chinese/
Japanese/Thai/Kazakh/Arabic/
Closed caption)
INF-15
SECTION 1 SERVICE INFORMATION
< RZ570 >
4) page 6
- TEMP (
- TEMP (
℃)
(IN) Intake air / (OPT) Optical module
(OUT) Exhaust air / (LD1) LD temperature1
(LD2) LD temperature2
- P.SENSOR
Luminance sensor detected value
(simplified calculation value)
R.SEG
Red segment : Y / x / y
G.SEG
Green segment : Y / x / y
B.SEG
Blue segment : Y / x / y
Y.SEG
Yellow segment : Y / x / y
[Note] •Different from the value measured by a illuminance meter.
- FAN MODE
Fan control mode
- atm
Atmospheric pressure sensor value [hPa]
- HEATPIPE1
- HEATPIPE2
- DMD
- CIRCUIT IN
Status of each fan [rpm]
- EXHAUST1
- EXHAUST2
- CENTER
5) page 7
- ON COUNT
Turn on times of each LD unit
- RUNTIME
Runtime of each LD unit
- LD STATUS
Number of the active laser elements
in each LD unit
(There is a case to be turned off intentionally
by menu setting)
6) page 8
- LD HISTORY
ON-OFF history log