DIS-35
SECTION 2 DISASSEMBLY PROCEDURE
<MZ16K/MZ13K/MZ10K>
When mounting or assembling the parts in the lighting case, the parts must be mounted in the specified location and direction 
as shown in the figure below.
3.6. Parts location and direction in the lighting case
The parts indicated with (*) are mounted by adhesive, therefore, they cannot be replaced individually.
Dichroic mirror(G)
Dichroic mirror (B)
Condenser lens 1 *
Condenser lens 2 *
Condenser lens 2 *
Mirror (B)
(Marker comes to 
back side) 
Mirror (R)
(Marker come to back 
side.)
Mirror (R)
(Marker comes to 
back side.)
Relay lens 1
Relay lens 3
Relay lens 2 *
Field lens
Fileld lens
PD1-PCB
PD2-PCB
PD1-PCB
Marker
Marker
DIS-36
SECTION 2 DISASSEMBLY PROCEDURE
<MZ16K/MZ13K/MZ10K>
<Cable wiring>
Reform the cables as shown in the figure below. Place the cables at the original position after replacing the parts.
SECTION
3
ADJ-1
SECTION 3 ADJUSTMENTS
(2019-11)
Illustrations of the projector and other parts may vary from the actual product.
CONTENTS
1. Adjustment Items and Procedures   . . . . . . . . . . . . . . . . . . . . . . . . . . ADJ-2
1.1. Polarizer adjustment
1.2. Lens calibration
1.3. Electrical convergence adjustment 
1.4. Adjusted data transfer
1.5. Panel type setting
1.6. Flicker adjustment
1.7. Model setting
1.8.  Ghost feedback calibration 
1.9. Clog sensor calibration
1.10. LD unit runtime reset
1.11. Date and time setup
2. Firmware update procedure  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ADJ-12
ADJ-2
SECTION 3 ADJUSTMENTS
<MZ16K/MZ13K/MZ10K>
1. Adjustment Items and Procedures
When the following parts are disassembled or replaced, please adjust the items according to the table below.
 
l
 Need to adjust  
m
 Need to check
Adjustment Item
Replaced Component
Remarks
Polar-
izer
Optical 
block
A-PCB
Others
1.1. Polarizer adjustment
l
l
1.2. Lens calibration
l
Lens 
mounter
Stepping 
motors
Take this adjustment if the projection lens is 
moved manually or shutdown while the lens mo-
tor is operating.
Not necessary if "1.4. Adjusted data transfer" is 
taken.
1.3  Electric convergence adjust-
ment
m
m
1.4. Adjusted data transfer
l
Transfer the data from old A-PCB to new one. If 
the original data cannot be exported or the opti-
cal block is replaced, get the standard gamma/
uniformity data from service web site.
1.5. Panel type setting
l
l
Not necessary if "1.4. Adjusted data transfer" is 
taken.
1.6. Flicker adjustment
l
l
1.7. Model setting
l
Not necessary if "1.4. Adjusted data transfer" is 
taken.
1.8.  Panel ghost feedback cali-
bration
l
l
Not necessary if "1.4. Adjustment data transfer" 
is taken.
1.9 Clog sensor calibration
l
1.10. LD unit runtime reset
LD unit
1.11. Date and time set up
l
Setup after taking item "1.4. Adjustment data 
transfer".