5. 3. 4. Error cord of system log
Bit
Error code (hex)
Details
Probable cause
0
LOW
ER
00000000 00000001 Intake air temperature warning
External temperature is too high,
Intake/exhaust holes are blocked,
Mounting of heatsink/heat pipe is abnormal,
Intake fan deterioration,
Atmospheric pressure sensor failure
1
00000000 00000002 DMD module temperature warning
2
00000000 00000004 LD1 temperature warning
3
00000000 00000008 LD2 temperature warning
4
00000000 00000010 Low temperature warning
Internal low-temperature anomaly (use environment temperature is low)
5
00000000 00000020 Intake air temperature error
External temperature is too high,
Intake/exhaust holes are blocked,
Mounting of heatsink/heat pipe is abnormal,
Intake fan deterioration,
Atmospheric pressure sensor failure
6
00000000 00000040 DMD module temperature error
7
00000000 00000080 LD1 temperature error
8
00000000 00000100 LD2 temperature error
9
00000000 00000200 Low temperature error
Internal low-temperature anomaly (use environment temperature is low)
10
00000000 00000400 Not used
11
00000000 00000800 LD1-1 synchronization signal abnormality
Abnormal occurrence at the time of light source lighting
(can be lit)
12
00000000 00001000 LD1-2 synchronization signal abnormality
13
00000000 00002000 LD2-1 synchronization signal abnormality
14
00000000 00004000 LD2-2 synchronization signal abnormality
15
00000000 00008000 LD1-1 factory adjusted value abnormality
16
00000000 00010000 LD1-2 factory adjusted value abnormality
17
00000000 00020000 LD2-1 factory adjusted value abnormality
18
00000000 00040000 LD2-2 factory adjusted value abnormality
19
00000000 00080000 LD1-1 voltage abnormality
Abnormal occurrence at the time of light source lighting
(lighting failure)
20
00000000 00100000 LD1-2 voltage abnormality
21
00000000 00200000 LD2-1 voltage abnormality
22
00000000 00400000 LD2-2 voltage abnormality
23
00000000 00800000 LD1-1 +20V voltage abnormality
24
00000000 01000000 LD1-2 +20V voltage abnormality
25
00000000 02000000 LD2-1 +20V voltage abnormality
26
00000000 04000000 LD2-2 +20V voltage abnormality
27
00000000 08000000 LD1-1 WDT reset abnormality
28
00000000 10000000 LD1-2 WDT reset abnormality
29
00000000 20000000 LD2-1 WDT reset abnormality
30
00000000 40000000 LD2-2 WDT reset abnormality
31
00000000 80000000 Not used
32
00000001 00000000  DC OUT error
USB terminal DC5V supply failure
33
00000002 00000000  Atmospheric pressure sensor error
Atmospheric pressure sensor failure (IC1513)
34
00000004 00000000 Intake air temperature sensor error
Temperature sensor failure, connector disconnect
35
00000008 00000000 DMD module temperature sensor error
36
00000010 00000000 LD1 temperature sensor error
37
00000020 00000000 LD2 temperature sensor error
38
00000040 00000000 Not used
39
00000080 00000000 Battery replacement warning for internal clock Battery level is low. (A-P.C.B)
40
00000100 00000000 Not used
41
00000200 00000000 Not used
42
00000400 00000000 Intake fan error
Fan or fan drive circuit is failure
Fan replacement time
43
00000800 00000000 Power fan error
44
00001000 00000000 Not used
45
00002000 00000000 Not used
46
00004000 00000000 Not used
47
00008000 00000000 Not used
48
00010000 00000000 Not used
49
00020000 00000000 Not used
50
00040000 00000000 Not used
51
00080000 00000000 Not used
52
00100000 00000000 Not used
53
00200000 00000000 Not used
54
00400000 00000000 Not used
55
00800000 00000000 Not used
56
01000000 00000000 Not used
57
02000000 00000000 Not used
58
04000000 00000000 Not used
59
08000000 00000000 Not used
60
10000000 00000000 Not used
61
20000000 00000000 Not used
62
40000000 00000000 Not used
63
80000000 00000000 Not used
INF-20
SECTION 1 SERVICE INFORMATION
< JX200F >
Bit
Error code (hex)
Details
Probable cause
64
U
PP
ER
00000000 00000001 LD1-1 synchronization signal abnormality
Abnormality occurred after lighting
(lighting state continuation)
65
00000000 00000002 LD1-2 synchronization signal abnormality
66
00000000 00000004 LD2-1 synchronization signal abnormality
67
00000000 00000008 LD2-2 synchronization signal abnormality
68
00000000 00000010 LD1-1 voltage abnormality
Abnormality occurred after lighting
(unlit state)
69
00000000 00000020 LD1-2 voltage abnormality
70
00000000 00000040 LD2-1 voltage abnormality
71
00000000 00000080 LD2-2 voltage abnormality
72
00000000 00000100 LD1-1 +20V voltage abnormality
73
00000000 00000200 LD1-2 +20V voltage abnormality
74
00000000 00000400 LD2-1 +20V voltage abnormality
75
00000000 00000800 LD2-2 +20V voltage abnormality
76
00000000 00001000 LD1-1 WDT reset abnormality
77
00000000 00002000 LD1-2 WDT reset abnormality
78
00000000 00004000 LD2-1 WDT reset abnormality
79
00000000 00008000 LD2-2 WDT reset abnormality
80
00000000 00010000 FPGA configuration error
FPGA configuration fault
81
00000000 00020000 Phosphor wheel error
Rotation speed is out of the specified value
82
00000000 00040000 Color wheel error
83
00000000 00080000 Not used
84
00000000 00100000 Not used
85
00000000 00200000 Not used
86
00000000 00400000 Not used
87
00000000 00800000 LD driver communication error
Driver microprocessor no response
88
00000000 01000000 Not used
89
00000000 02000000 Not used
90
00000000 04000000 Not used
91
00000000 08000000 Not used
92
00000000 10000000 Not used
93
00000000 20000000 Not used
94
00000000 40000000 Not used
95
00000000 80000000 Not used
96
00000001 00000000 Not used
97
00000002 00000000 Network microprocessor communication error
Network microprocessor no response
98
00000004 00000000 Sub microprocessor communication error
Sub microprocessor no response
99
00000008 00000000 IIC communication error 1
HDMI receiver or FPGA or audio DAC communication error
100
00000010 00000000 IIC communication error 2
EEPROM communication error
101
00000020 00000000 Not used
102
00000040 00000000 Not used
103
00000080 00000000 Not used
104
00000100 00000000 Not used
105
00000200 00000000 Not used
106
00000400 00000000 Not used
107
00000800 00000000 Not used
108
00001000 00000000 Not used
109
00002000 00000000 Not used
110
00004000 00000000 Not used
111
00008000 00000000 Not used
112
00010000 00000000 Not used
113
00020000 00000000 Not used
114
00040000 00000000 Not used
115
00080000 00000000 Not used
116
00100000 00000000 Not used
117
00200000 00000000 Not used
118
00400000 00000000 Not used
119
00800000 00000000 Not used
120
01000000 00000000 Not used
121
02000000 00000000 Not used
122
04000000 00000000 DMD error
DMD device error
123
08000000 00000000 Not used
124
10000000 00000000 Not used
125
20000000 00000000 Not used
126
40000000 00000000 Not used
127
80000000 00000000 Internal error
Main microprocessor internal error
INF-21
SECTION 1 SERVICE INFORMATION
< JX200F >
5. 4. Troubleshooting
• The letters in the left of inspection items indicate the P.C. Boards related to their respective descriptions.
• Please take care for electro-static discharges by using grounded wrist straps to release the electricity from the body.
■ Power does not turn ON. ([ON/STANDBY] LED does not light in red)
A
Disconnect the connectors A28.
Check the short circuit between pins of connector A28.
(1)-(2), (3)-(4)
 NG
A Check and replace A-P.C.Board.
OK
OK
Check the connection of each connector
   A28 - P2, A22 - V1, A27 - NT2(BtoB), P1 - AC inlet
 NG
•Connect the cables firmly
•If the cable is broken, replace it
A
Disconnect the connectors A28 and connecting A-PCB to NT-
PCB.
Check the short circuit between pins on connector A28. (1)-(2)
 NG
NT Check and replace NT-P.C.Board.
A Check and replace the A-P.C.Board
OK
f
 How to read the returned value and the self-diagnosis serial control command.
  Use the command "QVX:ERRS1" to get the information of Self-diagnosis for this model.
  The returned value provides the 128bit self-diagnosis information as follows.
  (Table below shows no error occurs)
 
bit
127
126
125
124
123
• • • • • • • • • • • • • •
4
3
2
1
0
ERRS1=
N
N
N
N
N
• • • • • • • • • • • • • •
N
N
N
N
N
   The returned value "N" indicates normal and "E" indicates error status. The first bit 0 starts from right and it ends by 128th 
bit at left.
  Example:  If the self-diagnosis information is inquired under the condition of the intake fan error, the "E" will appear on 42th 
bit as the below.
 
"E" will appear on 42th bit. 
bit
128
127
126
125
124
 • • • • • 
42
 • • • • • 
4
3
2
1
0
ERRS1=
N
N
N
N
N
 • • • • • 
E
 • • • • • s
N
N
N
N
N
P Check the fuse (F9101, PA9301)
 NG
P Check and replace P-P.C.Board.
OK
P
•Check the short circuit of ZNR (D9115).
•Check the short circuit of each parts.
     D9104, D9106, Q9104(D-S), Q9201(D-S), Q9202(D-S)
     (Normal : Several hundred Ω - several MΩ)
 NG
P Check and replace P-P.C.Board.
OK
P
Check the short circuit between pins on connector P2.
    (9)-(10), (7)-(8)
    (Normal : (9) DC6-12V, (7) 0V or DC12V)
 NG
P Check and replace P-P.C.Board.
OK
NT Check the voltage of Q1033 (4) pin.
    DC 3.3V
 NG
NT Check and replace NT-P.C.Board.
OK
j
INF-22
SECTION 1 SERVICE INFORMATION
< JX200F >
V V1 connector (9) pin signal waveform can be detected when 
remote control is operated
 NG
V Check and replace the V-P.C.Board
A Check and replace the A-P.C.Board
OK
NG
■ Power does not turn ON. ([STANDBY/ON] LED  does not light in green)
Check cables between A22 - V1 connector
    (broken wire etc)
 NG
Replace the cable
OK
OK
Check the connection of each connector
    A28 - P2, A22 - V1
 NG
Connect the cables firmly
V V1 connector (9) pin signal waveform can be detected when 
remote control is operated
 NG
V Check and replace the V-P.C. Board.
A Check and replace the A-P.C.Board
OK
Check the connection of each connector
    A29 - P4, A22 - V1
 NG
•Connect the cables firmly
•If the cable is broken, replace it
V V1 connector (1) pin changes from "Low" to "Hi" when press the 
power button
 NG
V Check and replace the V-P.C.Board
OK
OK
j
■ Remote control does not respond