10.13. Removal of Power Module
(1)
Remove the A-P.C.Board block according to the steps 1 through
3 in the section 10.3. "Removal of A-P.C.Board".
3 in the section 10.3. "Removal of A-P.C.Board".
(2)
Unscrew the 2 screws and remove the power fan.
(3)
Unscrew the 7 screws and remove the power module block.
(4)
Unscrew the 2 screws, remove the AC POWER cover and AC IN
terminal block.
terminal block.
10.14. Removal of Lamp Unit
(1)
Loosen the 1 screw until it idles, then remove the lamp unit cover.
(2)
Loosen the 3 screws until they idle, hold the handles and pull the
lamp unit out from the main unit.
lamp unit out from the main unit.
33
PT-DZ6710U / PT-DZ6710E / PT-DZ6700U / PT-DZ6700E / PT-DW6300US / PT-DW6300ES / PT-D6000US / PT-D6000ES
(3)
Note:
·
When installing the lamp unit in the main unit, place it in
a specified position and press the right and left sides of
the lamp unit (arrow positions shown in the figure), and
confirm the lamp unit is inserted securely.
a specified position and press the right and left sides of
the lamp unit (arrow positions shown in the figure), and
confirm the lamp unit is inserted securely.
Then, tighten each of 3 screws fixing the lamp unit, and
install the lamp unit cover.
install the lamp unit cover.
10.15. Removal of Projection Lens
(1)
Turn the lens cover counterclockwise and remove.
(2)
Fully turn the projection Lens counterclockwise.
(3)
While pressing the lens release button, turn the projection lens
counterclockwise in addition.
counterclockwise in addition.
(4)
Remove the projection lens.
34
PT-DZ6710U / PT-DZ6710E / PT-DZ6700U / PT-DZ6700E / PT-DW6300US / PT-DW6300ES / PT-D6000US / PT-D6000ES
10.16. Removal of Analysis/Synthesis Block
(1)
Remove the A-P.C.Board block according to the steps 1 through
3 in the section 10.3. "Removal of A-P.C.Board".
3 in the section 10.3. "Removal of A-P.C.Board".
(2)
Loosen the each of 3 screws until they idle and remove the lamp
units 1 and 2.
units 1 and 2.
(3)
Unscrew the 1 screw and release the terminal for lamp unit 1.
(4)
Open the lamp socket holder and separate the socket and the
plug for the connection.
plug for the connection.
(5)
Unscrew the 4 screws and release the block of intake air duct
and ACF drive unit.
and ACF drive unit.
(6)
Unscrew the 7 screws and remove the Analysis/Synthesis block.
35
PT-DZ6710U / PT-DZ6710E / PT-DZ6700U / PT-DZ6700E / PT-DW6300US / PT-DW6300ES / PT-D6000US / PT-D6000ES
(7)
Unscrew the 2 screws and remove the lamp 1 cooling unit.
(8)
Unscrew each of 1 screw and remove the 2 thermofuse holders.
(9)
Unscrew the 1 screws and remove the color wheel cover.
(10) Unscrew the 2 screws and remove the optical holding metal
fixure.
(11) Unscrew the 4 screws and separate the analysis block and
synthesis block.
Note:
·
Work carefully because the rod is installed in the
synthesis block.
synthesis block.
36
PT-DZ6710U / PT-DZ6710E / PT-DZ6700U / PT-DZ6700E / PT-DW6300US / PT-DW6300ES / PT-D6000US / PT-D6000ES
Click on the first or last page to see other PT-DZ6710U / PT-DZ6710E / PT-DZ6700U / PT-DZ6700E / PT-DW6300US / PT-DW6300ES / PT-D6000US / PT-D6000ES / PT-DZ6710UL / PT-DZ6710EL / PT-DZ6700UL / PT-DZ6700EL / PT-DW6300ULS / PT-DW6300ELS / PT-D6000ULS / PT-D6000ELS / PT-D6000ELK / PT-D6000EK / PT-DW630 service manuals if exist.