INF - 13
4. External Controls
  4. 1. Control through Serial terminal
    4. 1. 1. Connection
● 
Single projector
● 
Multiple projectors
    4. 1. 2. Pin assignments and signal names
    4. 1. 3. Communication conditions
    4. 1. 4. Communication condition setting
1. Press MENU button of main body or remote controller.
   Go to Main menu --> Projector setup. In sub menu,
    select "RS-232C" and press ENTER.
2. Select communication condition by pressing  ▲ ▼ button.
    Set it with pressing  
    button.
3. Press MENU button 3 times and return to regular display.
    4. 1. 5. Cable specification
・When connected to a computer
・When multiple projectors are connected
SERIAL terminals which are on the side of the projector conform to RS-232C standard. This projector can be controlled
by a PC which is connected as shown below. Also SERIAL OUT terminal is provided to enable plural projector control.
INF - 14
    4. 1. 6. Basic format
Transmission from the computer starts with STX, then the ID, command, parameter, and ETX are sent in this order.
Add parameters according to the details of control.
1. Basic control command (without parameter)
2. Basic control command (with parameters)
3. Basic control command (with sub command)
4. Operation
Specifies the method of processing the value specified by parameters.
 Description
 Sets the value specified by the parameter.
 Adds the value specified by the parameter to the current value.
5. Sign
Specifies positive or negative of the value specified by parameters.
 Description
 The value specified by the parameter is a positive value or 0 (zero).
 The value specified by the parameter is a negative value.
6. Parameters
Specify the setting or adjustment value by right justification (0 is not suppressed).
For example, when the setting value is "1", set it as "00001".
7. ID of the basic control command
This projector will respond to the computer only in the following cases.
    - If the sent ID coincides with the projector ID.
    - RESPONSE(ID ALL) in RS232C settings of this projector is ON and the sent ID is ALL.
    - Or If Group (A-Z) of the sent ID coincides with GROUP in RS232C settings of this projector and
       RESPONSE(ID GROUP) in RS232C settings of this projector is ON.
Specifically, please refer to a separate volume "Control Commands". 
8. Response (Callback) of the basic control command
In the period when the command can be accepted.
Differs according to each command.
In the period when commands cannot be accepted.
In case of the parameter error or REMOTE2 effective.
52h
32h
34h
30h
4
0
Hexadecimal
30h
31h
02h
45h
Hexadecimal
Character
Character
03h
E
R
4
0
2
03h
1
E
R
02h
45h
Code
=
End
(ETX)
1 byte
52h
4 byte
Code
Undefined length
3 byte
_( underbar)
1 byte
34h
1 byte
1 byte
5 byte
1 byte
Parameter
Sign
4 byte
1 byte
3 byte
Start
(STX)
1 byte
Command
Start
(STX)
ID
1 byte
1 byte
4 byte
1 byte
1 byte
1 byte
End
(ETX)
End
(ETX)
Separator
(colon)
Separator
(colon)
Parameter
Parameter
Operation
5 byte
1 byte
ID
Separator
(semicolon)
Command
Separator
(semicolon)
Command
Separator
(semicolon)
Start
(STX)
3 byte
ID
INF - 15
9. Attention
・ If a command is transmitted after the lamp starts illuminating, there may be a delay in response or the command
may not be executed. Try sending or receiving any command after 60 seconds.
・ When transmitting multiple commands, be sure to wait until 0.5 seconds has elapsed after receiving the response
from the projector before sending the next command.
・ It might take time by the time the response returns because the command is processed in the projector.
Set the time-out to 10 seconds or longer.
・ When multiple projectors are all controlled
  1) Set a different ID for each projector
  2) Set [RESPONSE(ID ALL)] to [ON] in only one projector
  3) Set [RESPONSE(ID ALL)] to [OFF] for all other projectors set in Step 2)
・ When multiple projectors are all controlled by group unit
  1) Set a different ID for each projector
  2) Set [RESPONSE(ID GROUP)] to [ON] in only one projector
  3) Set [RESPONSE(ID GROUP)] to [OFF] for all other projectors set in Step 2)
  4. 2. Control through LAN terminal
Connection and command transmission changes depending on mode (admin password is set or not with web control).
Control according to the procedure in "4.2.2" on the protection mode (the password is set), and according to the
procedure in "4.2.3" on the unprotected mode (the password is not set).
    4. 2. 1. Connection example
    4. 2. 2. When Web control administrator rights password is set (Protect mode)
      4. 2. 2. 1. Connecting
1. Obtain the IP address and port number (Initial setting value = 1024) of the projector and request for a connection 
     to the projector. 
     You can obtain both the IP address and the port number from the menu screen of the projector.
: Obtain from the main menu → [NETWORK] → [NETWORK STATUS]
: Obtain from the main menu → [NETWORK] → [NETWORK CONTROL] → [COMMAND PORT]
2. Check the response from the projector
・ Response data
Mode: 1 = Protect mode
3. Generate a 32-byte hash value from the following data using MD5 algorithm.
“xxxxxx:yyyyy:zzzzzzzz”
 Administrator rights user name for Web control (default user name is “admin1”)
 Password of above administrator rights user (default password is “panasonic”)
 8-byte random number obtained in Step 2)
: colon : Separator
yyyyy
zzzzzzzz
‘1’
IP address
Port number
1 byte
1 byte
“zzzzzzzz”
8 bytes
(ASCII string)
Note: Lan cable and Hub are not standard accessories.
          When connected directly, cross type cable is
          recommended.
Termination symbol
Data section
Blank
Mode
Blank
Random number section
“NTCONTROL”
‘  ’
(CR)
9 bytes
1 byte
xxxxxx
‘  ’
Possible to control this projector by connecting PC to the LAN terminal on the side of this projector.
0x20
0x31
0x20
0x0d
(ASCII code hexadecimal number)
1 byte
INF - 16
      4. 2. 2. 2. Command transmission method
Transmit using the following command formats.
Transmitted data
Received data
Error response
“ERR1”
Undefined control command
“ERR2”
Out of parameter range
“ERR3”
Busy state or no-acceptable period
“ERR4”
Timeout or no-acceptable period
“ERR5”
Wrong data length
“ERRA”
Password mismatch
Example: Query Power "QPW"
1. Connects to the projector
IP = 192.168.0.8      port = 1024
2. Receives a response
Response = "NTCONTROL 1 1aa6c14e" + (CR)
"1aa6c14e" = 8 bytes random characters
3. Generates a hash value (message digest) from "admin1:panasonic:1aa6c14e" by using the MD5 algorism.
"admin1" = Administrator authority user-name
"panasonic" = Password corresponding to "admin1"
Hash value = "01466bc27ed8c0b7e607471580c55953"
4. Transmits the command
Transmission data = "01466bc27ed8c0b7e607471580c5595300QPW" + (CR)
5. Receives a response.
Reception data = "00000" + (CR)
6. Disconnects the connection with the projector.
1 byte
0x30
Control command
0x0d
1 byte
0x0d
1 byte
1 byte
Undefined length
Termination symbol
‘0’
(CR)
Data section
Control command
‘0’
‘0’
(ASCII string)
1 byte
(ASCII string)
Undefined length
Header
‘0’
0x30
1 byte
Hash value
32 bytes
(4.2.2.1.-3)
Data section
Termination symbol
(CR)
Error message
Termination symbol
4 bytes
 1 byte
0x30
0x30
Header
(CR)
0x0d