10 Replacement of Lamp Unit
Cautions
     ·    
Wait until the lamp is cooled sufficiently before replacing the lamp unit.
10.1. Precautions on Lamp Unit Replacement
Remove the power plug and confirm that the surroundings of the lamp unit have cooled off.
     ·    
Be careful when handling a light source lamp. The lamp unit has high internal pressure. If improperly handled, explosion might
result.
     ·    
A used lamp unit may burst if it is handled violently.
For disposition of used lamps, request an industrial waste disposal contractor.
     ·    
Do not reset the cumulative time, except when the lamp unit has been replaced with a new unit.
     ·    
If you continue to use a lamp after the replacement time, the lamp may break.
     ·    
Philips screwdriver is necessary when replacing a lamp unit.
Take care not to slip your hand when using a screwdriver.
     ·    
A lamp unit is an optional part. Contact the dealer.
Replacement lamp unit model No.: ET-LAD55 (single bulb), ET-LAD55W (double bulbs)
Rating: 300 W
Long life lamp unit model No.: ET-LAD55L (single bulb), ET-LAD55LW (double bulbs)
Rating: 160 W
     ·    
Other lamps than specified above cannot be used. Be sure to use the specified lamp.
10.2. Timing of Lamp Unit Replacement
The lamp used for the light source has its due life. The life of light source lamp used in the main unit is 1 500 hours
*1
(when “LAMP
POWER” is “HIGH” and “LAMP SELECT” is “DUAL”). However, it may happen that the lamp becomes dead (will not light) by the
time of 1 500 hours
*1
depending on the characteristics of individual lamps and working conditions (lamps may reduce their life
affected by the times of lighting and the intervals between previous lighting and next lighting). Therefore, it is strongly
recommended for the user to keep a spare bulb. If your lamp unit is not replaced after 1 300 hours
*2
(with “LAMP POWER” set at
“HIGH”), power supply will be turned off automatically at the time of 1 500 hours
*1
, entering a standby state. After 1 500 hours
*1
of
initial lighting, power supply is turned off automatically about 10 minutes later, entering a standby state even if it is turned on again.
21
PT-D5600U / PT-D5600E / PT-D5600UL / PT-D5600EL / PT-DW5000U / PT-DW5000E / PT-DW5000UL / PT-DW5000EL
10.3. Indication of Lamp Monitor
10.4. Procedure of Lamp Unit Replacement
NOTE:
     ·    
Be sure to follow steps 11 to 17 in ten minutes after turning on the projector because the projector is turned off in ten
minutes if the RUNTIME indication is 1 500h or more.
22
PT-D5600U / PT-D5600E / PT-D5600UL / PT-D5600EL / PT-DW5000U / PT-DW5000E / PT-DW5000UL / PT-DW5000EL
23
PT-D5600U / PT-D5600E / PT-D5600UL / PT-D5600EL / PT-DW5000U / PT-DW5000E / PT-DW5000UL / PT-DW5000EL
24
PT-D5600U / PT-D5600E / PT-D5600UL / PT-D5600EL / PT-DW5000U / PT-DW5000E / PT-DW5000UL / PT-DW5000EL
Page of 127
Display

Click on the first or last page to see other PT-D5600U / PT-D5600E / PT-D5600UL / PT-D5600EL / PT-DW5000U / PT-DW5000E / PT-DW5000UL / PT-DW5000EL service manuals if exist.