Panasonic DP-C262 / DP-C322 (serv.man2) Service Manual ▷ View online

121
APR 2005
Ver. 1.1
DP-C262/322
(15) Remove 1 Screw (S6).
(16) Remove the Hopper Unit as illustrated.
Note:
Pull out the bottom portion by clasping with the left
forefinger.
<Cleaning the Supply Cylinder>
(17) Clean the Supply Cylinder with a Vacuum 
cleaner.
(18) Clean the Toner Entrance
 
with a Vacuum 
cleaner.
122
DP-C262/322
APR 2005
Ver. 1.1
(19) Release the Lever Arm.
(20) Remove 2 Screws (Y1).
(21) Remove the WTB Lower Cover (4401).
(22) Release 2 Harness Clamps.
(23) Disconnect the Developer Harness.
(24) Remove 3 Screws (X5).
(25) Remove the Developer Front Bracket (4422).
123
APR 2005
Ver. 1.1
DP-C262/322
<Cleaning the Developer Cover>
(26) Clean the Developer Front Bracket (4422) with 
a Vacuum cleaner.
(27) Pull out the Developer Unit (Cyan) (5443).
Note:
Do not open the shutter, or Toner will spill out. 
Note:
Ensure the Lever Arm is at the maximum down 
position, or Drum may get damaged.
<Installing the new Developer Unit>
(28) Remove the new Developer Unit out of the box.
(29) Remove all the Shipping materials.
(30) Gently peel the Tape off in the direction of the 
arrow.
124
DP-C262/322
APR 2005
Ver. 1.1
(31) Remove 2 Screws (X8).
(32) Remove the Developer Cover (5401) by 
releasing 4 latches.
<Replacing the Developer>
 
Note:
Only if a problem occurs, perform the step below.
If there is no problem, skip to the step (34).
(33) Turn the Developer Unit upside down over a 
suitable waste container or a sheet of paper, and 
dump the used Developer and Toner by rotating 
the gear counterclockwise. 
<Pouring the Developer>
(34) Shake the Developer Bottle a few times to 
loosen its contents.
(35) Carefully pour the developer evenly into the 
developer unit while turning the Gear as 
illustrated. Make sure to empty the bottle.
(36) Reinstall the Developer Cover.
(37) Install the new Developer Unit.
(38) Connect the Developer Harness.
(39) Hook 2 Harness Clamps.
(40) Reinstall the Developer Front Bracket.
Note:
When reinstalling the Developer Cover, exercise
care not to pinch the Harness with the Cover.