Panasonic DP-2000 / DP-2500 / DP-3000 Service Manual ▷ View online
93
(44) Remove the Turn Guide (1007) in the direction
of the arrow.
(45) 3 Screws (4N).
(46) Push slightly on both sides of the Fuser Frame
(46) Push slightly on both sides of the Fuser Frame
(1017) outwards and remove the Side Fuser
Cover (1004).
Cover (1004).
(47) 3 Screws (4N).
(48) Remove the Lower Fuser Cover (1003).
(48) Remove the Lower Fuser Cover (1003).
(49) 2 Screws (4N).
(50) Remove the Fuser Paper Guide (1019).
(50) Remove the Fuser Paper Guide (1019).
(44)
(45)
(46)
(45)
(47)
(48)
(49)
(50)
94
(51) Remove the 2 Screws (1033), the 2 Pressure
Springs (1029) and the 2 Washers (1052).
(52) Remove the Pressure Roller (1027).
(53) Remove 2 Bearings (1039).
Note:
1. When re-installing, make sure to install
with Bearing’s Retainer Ring facing
towards the Roller.
towards the Roller.
2. Do not scratch the surface of the Pressure
Roller when removing or re-installing it.
Cleaning Pressure Roller:
Clean the surface of the Pressure Roller with
a soft cloth, saturated with isopropyl alcohol.
a soft cloth, saturated with isopropyl alcohol.
(54) Remove the Right Pressure Roller Plate
(1015) and the Left Pressure Roller Plate
(1016).
(1016).
<Precautions in handling Pressure Roller Plates>
When re-installing the Pressure Roller Plates,
make sure that the Bearings are installed properly
first (Refer to the step (53) and then install the
Pressure Roller Plates as shown in the illustration.
make sure that the Bearings are installed properly
first (Refer to the step (53) and then install the
Pressure Roller Plates as shown in the illustration.
(51)
(52)
(53)
(53)
(54)
(54)
Pressure Roller
Plate
Bearing
95
(55) Remove the E20 Gear (937), E25 Gear (941),
and E41 Free Gear (1012).
(56) Remove the 2 C-Type Rings (1030).
(57) Remove the E40 Heat Roller Gear (1014).
(58) Remove the Plate Spacer (1023).
(59) Remove the 2 Insulation Bushings (1006).
(60) Remove the 2 Bearings (1046).
(61) Remove the Fuser Roller (1026).
(58) Remove the Plate Spacer (1023).
(59) Remove the 2 Insulation Bushings (1006).
(60) Remove the 2 Bearings (1046).
(61) Remove the Fuser Roller (1026).
Note:
1. The Plate Spacer is installed only to the non-
Gear side.
2. Do not scratch the surface of the Fuser Roller
when removing or re-installing it.
Cleaning Insulation Bushings:
Clean the Insulation Bushings with a soft cloth,
saturated with isopropyl alcohol.
saturated with isopropyl alcohol.
Cleaning Fuser Roller:
Clean the surface of the Fuser Roller with a soft
cloth, saturated with isopropyl alcohol.
cloth, saturated with isopropyl alcohol.
(55)
(56)
(56)
(57)
(59)
(60)
(61)
(58)
(59)
(60)
96
2.2.9.
OPC Drum, Cleaning Blade Assembly, Mag Roller, Dr Blade, Mag Roller Joint, Bias
Charge Roller, Front Cleaning Felt, Rear Cleaning Felt, Cleaning Sponge, Scoop
Sheet, Gap Roller, Development Felt
Charge Roller, Front Cleaning Felt, Rear Cleaning Felt, Cleaning Sponge, Scoop
Sheet, Gap Roller, Development Felt
(1) Turn the Power Switch to the OFF (O) position.
(2) Open the Front Cover (528).
(3) Remove the Waste Toner Box and the Toner
(2) Open the Front Cover (528).
(3) Remove the Waste Toner Box and the Toner
Cartridge. (Refer to Users Guide)
(4) Open the Right Cover (1201) Assembly.
(5) Press down on the Release Latch (1109) and
(5) Press down on the Release Latch (1109) and
pull the Process Assembly out slowly until it
stops.
stops.
(6) 2 Screws and then remove the Process
Assembly from the machine.
(7) Release 2 OPC Drum Latches (713) and turn
the OPC Assembly in the direction of the arrow.
Note:
Note:
To prevent Toner Spill, do not turn the
Process Unit over.
Process Unit over.
(8) 1 Thumb Screw (779).
(9) Remove the Waste Toner Chamber (704)
(9) Remove the Waste Toner Chamber (704)
Assembly.
(4)
(6)
(6)
(6)
(5)
(7)
(8)
(9)
Click on the first or last page to see other DP-2000 / DP-2500 / DP-3000 service manuals if exist.