DOWNLOAD Panasonic DP-2000 / DP-2500 / DP-3000 Service Manual ↓ Size: 82.23 MB | Pages: 127 in PDF or view online for FREE

Model
DP-2000 DP-2500 DP-3000
Pages
127
Size
82.23 MB
Type
PDF
Document
Service Manual
Brand
Device
Copying Equipment / DIGITAL
File
dp-2000-dp-2500-dp-3000.pdf
Date

Panasonic DP-2000 / DP-2500 / DP-3000 Service Manual ▷ View online

89
(11) Remove the Harnesses from the Clamp and the 
Band. The Band on the rear of the machine is 
easily removed as shown on the left. Do not cut it 
off.
Note:
When re-installing, makes sure to tighten the 
Band properly so that harnesses are not 
touching the gears of the Fuser Unit.
(12) 1 Screw (19).
(13) Remove the Fuser Lamp Harness Cover 
(1022).
(14) 4 Screws (4N).
(15) Disconnect 3 Connectors.
Note:
When re-installing, make sure to connect the 
White Connector to the rear, the Blue 
Connector to the middle, and the Red 
Connector to the front of the Fuser Unit as 
shown on the left. 
If the Dual-Path Exit Guide Unit (DA-FK200) 
is installed, it must be removed first.
(16) Remove the Fuser Unit.
(17) 1 Screw (36).
Note:
To prevent damaging the recessed screw 
seat, ensure to insert this shorter machine 
Screw (36) when re-attaching the Shield Plate 
onto the Fuser Unit.
(18) Remove the Shield Plate (1054).
(19) Remove the 2 Star Wheel Plates (1057) 
Assembly.
(11)
(11)
(14)
(12)
(13)
(14)
(16)
(15)
White
Blue
Red
(18)
(17)
(19)
90
(20) 1 Screw (4N).
(21) 2 Screws (16).
(22) Remove 2 Lamp Brackets (1018).
(23) Remove 2 Fuser Lamps.
Note:
Make sure to check the wattage of each 
Fuser Lamp when replacing.
<Precautions in handling the Fuser Lamps>
Note:
1. When re-installing, route the Harnesses along 
the hooks as illustrated on the left.
2. Be sure to install the longer Harness to the Gear 
side and the shorter Harness to the other side.
3. Make sure that the 850W Fuser Lamp (White 
Harness) is plugged into the upper left slot and 
the 400W Fuser Lamp (Red Harness) is plugged 
into the lower right slot.
4. Route the Harnesses along the 3 hooks as 
illustrated by (A) on the left.
5. Do not touch the glass portion of the Fuser Lamp 
with bare hands. Grease from the fingerprints will 
shorten its life cycle, use a soft cloth, saturated 
with isopropyl alcohol to clean fingerprints.
6. Use care when handling the Fuser Lamps to 
avoid breakage.
(20)
(21)
(22)
(22)
(23)
(A)
(A)
91
(24) Remove the 2 Separation Wire Springs (A) 
(1048) and the 2 Separation Springs (B) 
(1053).
(25) Remove the 6 Separations (1047).
 
Cleaning Separations:
Clean the Separations with a soft cloth, 
saturated with isopropyl alcohol.
(26) Disconnect the Sensor Connector.
(27) Move the Actuator in the direction of the arrow, 
release the Latch Hooks and remove the Paper 
Exit Sensor
 (1045).
(28) 2 Screws (1Q).
(29) Release the Harness from the Hook.
(30) Remove the Thermistor Assembly 1 (1041) 
and the Thermistor Assembly 2 (1042).
Note:
When re-installing, make sure that the 
Thermistor Assembly 1 (the longer Harness) 
is installed in the center and the Thermistor 
Assembly 2 (the shorter Harness) is installed 
to the left side as shown in the illustration.
Cleaning Thermistors:
Clean the surface of the Thermistors only with 
a soft dry cloth.
(31) 2 Screws (23).
(32) Remove the Thermal Fuse (1040).
(A)
(25)
(25)
(B)
(25)
(26)
(27)
(28)
(30)
(28)
(29)
(32)
(31)
92
(33) 1 Screw (4N).
(34) Remove the Thermostat (1038).
(35) Open the Fuser Jam Cover (1011).
(36) Remove the 5 Separation Sheets (1060).
(37) Remove the Guide A Spring (1032).
(38) 4 Screws (4N).
(39) 1 Screw (16).
(40) Remove the Fuser Upper Cover (1002).
(41) Remove the E18 Drive Gear (1013).
(42) Remove the 2 P3.5L5 Bushings (1008, 1009).
Note:
When re-installing, make sure to install the 
Green Colored Bushing (1009) to the Gear 
side and the Black Colored Bushing (1008) to 
the non-Gear side.
(43) Remove the Exit Roller (1028).
Cleaning Exit Roller:
Clean the surface of the Exit Roller with a soft 
cloth, saturated with isopropyl alcohol.
(33)
(34)
(35)
(36)
(37)
(40)
(38)x4
(39)
(41)
(42)
(43)
Page of 127