Panasonic DP-2000 / DP-2500 / DP-3000 Service Manual ▷ View online
89
(11) Remove the Harnesses from the Clamp and the
Band. The Band on the rear of the machine is
easily removed as shown on the left. Do not cut it
off.
Note:
easily removed as shown on the left. Do not cut it
off.
Note:
When re-installing, makes sure to tighten the
Band properly so that harnesses are not
touching the gears of the Fuser Unit.
Band properly so that harnesses are not
touching the gears of the Fuser Unit.
(12) 1 Screw (19).
(13) Remove the Fuser Lamp Harness Cover
(13) Remove the Fuser Lamp Harness Cover
(1022).
(14) 4 Screws (4N).
(15) Disconnect 3 Connectors.
Note:
When re-installing, make sure to connect the
White Connector to the rear, the Blue
Connector to the middle, and the Red
Connector to the front of the Fuser Unit as
shown on the left.
If the Dual-Path Exit Guide Unit (DA-FK200)
is installed, it must be removed first.
White Connector to the rear, the Blue
Connector to the middle, and the Red
Connector to the front of the Fuser Unit as
shown on the left.
If the Dual-Path Exit Guide Unit (DA-FK200)
is installed, it must be removed first.
(16) Remove the Fuser Unit.
(17) 1 Screw (36).
Note:
To prevent damaging the recessed screw
seat, ensure to insert this shorter machine
Screw (36) when re-attaching the Shield Plate
onto the Fuser Unit.
seat, ensure to insert this shorter machine
Screw (36) when re-attaching the Shield Plate
onto the Fuser Unit.
(18) Remove the Shield Plate (1054).
(19) Remove the 2 Star Wheel Plates (1057)
(19) Remove the 2 Star Wheel Plates (1057)
Assembly.
(11)
(11)
(14)
(12)
(13)
(14)
(16)
(15)
White
Blue
Red
(18)
(17)
(19)
90
(20) 1 Screw (4N).
(21) 2 Screws (16).
(22) Remove 2 Lamp Brackets (1018).
(21) 2 Screws (16).
(22) Remove 2 Lamp Brackets (1018).
(23) Remove 2 Fuser Lamps.
Note:
Make sure to check the wattage of each
Fuser Lamp when replacing.
Fuser Lamp when replacing.
<Precautions in handling the Fuser Lamps>
Note:
1. When re-installing, route the Harnesses along
the hooks as illustrated on the left.
2. Be sure to install the longer Harness to the Gear
side and the shorter Harness to the other side.
3. Make sure that the 850W Fuser Lamp (White
Harness) is plugged into the upper left slot and
the 400W Fuser Lamp (Red Harness) is plugged
into the lower right slot.
the 400W Fuser Lamp (Red Harness) is plugged
into the lower right slot.
4. Route the Harnesses along the 3 hooks as
illustrated by (A) on the left.
5. Do not touch the glass portion of the Fuser Lamp
with bare hands. Grease from the fingerprints will
shorten its life cycle, use a soft cloth, saturated
with isopropyl alcohol to clean fingerprints.
shorten its life cycle, use a soft cloth, saturated
with isopropyl alcohol to clean fingerprints.
6. Use care when handling the Fuser Lamps to
avoid breakage.
(20)
(21)
(22)
(22)
(23)
(A)
(A)
91
(24) Remove the 2 Separation Wire Springs (A)
(1048) and the 2 Separation Springs (B)
(1053).
(1053).
(25) Remove the 6 Separations (1047).
Cleaning Separations:
Clean the Separations with a soft cloth,
saturated with isopropyl alcohol.
saturated with isopropyl alcohol.
(26) Disconnect the Sensor Connector.
(27) Move the Actuator in the direction of the arrow,
(27) Move the Actuator in the direction of the arrow,
release the Latch Hooks and remove the Paper
Exit Sensor (1045).
Exit Sensor (1045).
(28) 2 Screws (1Q).
(29) Release the Harness from the Hook.
(30) Remove the Thermistor Assembly 1 (1041)
(29) Release the Harness from the Hook.
(30) Remove the Thermistor Assembly 1 (1041)
and the Thermistor Assembly 2 (1042).
Note:
Note:
When re-installing, make sure that the
Thermistor Assembly 1 (the longer Harness)
is installed in the center and the Thermistor
Assembly 2 (the shorter Harness) is installed
to the left side as shown in the illustration.
Thermistor Assembly 1 (the longer Harness)
is installed in the center and the Thermistor
Assembly 2 (the shorter Harness) is installed
to the left side as shown in the illustration.
Cleaning Thermistors:
Clean the surface of the Thermistors only with
a soft dry cloth.
a soft dry cloth.
(31) 2 Screws (23).
(32) Remove the Thermal Fuse (1040).
(32) Remove the Thermal Fuse (1040).
(A)
(25)
(25)
(B)
(25)
(26)
(27)
(28)
(30)
(28)
(29)
(32)
(31)
92
(33) 1 Screw (4N).
(34) Remove the Thermostat (1038).
(34) Remove the Thermostat (1038).
(35) Open the Fuser Jam Cover (1011).
(36) Remove the 5 Separation Sheets (1060).
(36) Remove the 5 Separation Sheets (1060).
(37) Remove the Guide A Spring (1032).
(38) 4 Screws (4N).
(39) 1 Screw (16).
(40) Remove the Fuser Upper Cover (1002).
(38) 4 Screws (4N).
(39) 1 Screw (16).
(40) Remove the Fuser Upper Cover (1002).
(41) Remove the E18 Drive Gear (1013).
(42) Remove the 2 P3.5L5 Bushings (1008, 1009).
(42) Remove the 2 P3.5L5 Bushings (1008, 1009).
Note:
When re-installing, make sure to install the
Green Colored Bushing (1009) to the Gear
side and the Black Colored Bushing (1008) to
the non-Gear side.
Green Colored Bushing (1009) to the Gear
side and the Black Colored Bushing (1008) to
the non-Gear side.
(43) Remove the Exit Roller (1028).
Cleaning Exit Roller:
Clean the surface of the Exit Roller with a soft
cloth, saturated with isopropyl alcohol.
cloth, saturated with isopropyl alcohol.
(33)
(34)
(35)
(36)
(37)
(40)
(38)x4
(39)
(41)
(42)
(43)
Click on the first or last page to see other DP-2000 / DP-2500 / DP-3000 service manuals if exist.