6 Service Mode
6.1.
CAT (Computer Aided Test) mode
To exit the CAT mode, access the ID mode and switch off the main power.
6.1.1.
IIC mode
Select the IIC mode by Up/Down button on the remote control at the front page of CAT mode and then press the Action button on
the remote control.
the remote control.
Subject and item are mentioned on “IIC mode structure”.
To exit the IIC mode, press the R button on the remote control.
To exit the IIC mode, press the R button on the remote control.
14
TH-65PF30W / TH-65PF30T / TH-65PF30G
6.1.2.
CD mode
Select the CD mode by Up/Down button on the remote control at the front page of CAT mode and then press the Mute button on
the remote control more than 3 seconds.
the remote control more than 3 seconds.
Memory data change
To exit the CD mode, press the R button on the remote control.
6.1.3.
NW mode
Note :
To use the network function, set each “Network Setup” setting and make sure to set the “Control I/F Select” to “LAN”.
Select the NW mode by Up/Down button on the remote control at the front page of CAT mode and then press the Action button
on the remote control.
on the remote control.
To exit the NW mode, press the R button on the remote control.
15
TH-65PF30W / TH-65PF30T / TH-65PF30G
6.1.4.
SD mode
Select the SD mode by Up/Down button on the remote control at the front page of CAT mode and then press the Action button on
the remote control.
the remote control.
To exit the SD mode, press the R button on the remote control.
6.1.5.
MS mode
Select the MS mode by Up/Down button on the remote control at the front page of CAT mode and then press the Mute button on
the remote control more than 3 seconds.
the remote control more than 3 seconds.
To exit the MS mode, press the R button on the remote control.
Caution:
Market Select should be set after exchange of A-Board.
Destination number
Default setting
Number
Model (Destination)
0
60/65PF30 (Japan)
1
60/65PF30U (North America)
3
60/65PF30W (Asia, Oceania, ME)
5
65PF30T (Taiwan)
15
65PF30G (Global)
18
60/65PF30C (China)
20
60/65PF30ER (Europe, CIS)
Number
Destination
1
North America
16
TH-65PF30W / TH-65PF30T / TH-65PF30G
6.1.6.
ID mode
Select the ID mode by Up/Down button on the remote control at the front page of CAT mode and then press the Mute button on
the remote control more than 3 seconds.
the remote control more than 3 seconds.
To exit the ID mode, press the R button on the remote control.