4) Motor troubles and other electric faults 
 
a) Motor windings have been burned or short-circuited between turns Analysis of Trouble 
When motor windings have been burned or short-circuited between turns, the fuse will be blown 
repeatedly, and the blowout occurs particularly at the instant when you close the knife switch. 
Remedy Check the terminals and the outer casing to see whether they are short-circuited, and 
measure the resistance of each phase with an ohmmeter. If short circuit occurs or the resistance of 
a certain phase is low, this means that short circuit does exist in the windings and/or between turns, 
and insulation layers have been burned or deteriorated. A multimeter can be used in this inspection, 
too. I f the insulation resistance is lower than 2 M
, this means that the insulation layer is already 
breakdown. If the motor has been burned, repair it or replaced it with a new one. 
 
b) Fault of control relay 
Analysis of Trouble 
Overheat burnout or wear of control relay contacts may occur generally. All these will cause poor 
contact in electricity. 
Remedy 
Dismantle it to repair, or replace it with a new one. 
 
c) Poor electric contactor in thermostat 
Analysis of Trouble 
Burnout of contactor and leakage of temperature sensing agent may occur generally. 
Remedy 
Replace the old with a new one. 
 
d) Check the terminals for loose connection and electric circuits for other abnormal phenomena. 
 
5) Mechanical faults of compressor 
a) Seizing of shaft 
This phenomenon is caused mostly by poor lubrication, such as insufficient quantity of lubricant, 
clogging in the lubricant oil line, or intermittent lubricant oil supply. Dirt and other impurities in the 
lubricant oil will increase its viscosity and cause the shaft to be seized. Copper plating may also 
result in seizing of shaft. 
 
b) Seizing of piston 
This is caused by too small fit clearance between the piston and cylinder or expansion due to heat. 
Judgement of seizing shaft and piston: After the refrigerator has been powered on, the compressor 
will not start and run, but a slight hum sound can be heard, and several seconds later, thermal 
protective relay will actuate and make the contacts open; this process will occur repeatedly, but the 
compressor cannot be started. 
E. Compressor won't stop 
Sometimes, the compressor will run continuously (for several hours or run without end), If the food 
placed in the refrigerator is not too much, there may be the following two situations: i) the refrigerator 
very low, this means that the control system is probably out of order; ii) the control system works 
normally, and there are troubles in the refrigerating system or other parts. 
 
 
 
22 
1) Temperature is set improperly 
 
a) The temperature control knob is set to the "coldest" position. This position is to be used for fast 
freezing or continuous running, its temperature for power off is too low, therefore, the compressor 
won't stop and the temperature in the refrigerator becomes lower and lower . 
 
b) Inspection method: check the temperature control knob to see whether it is set in the position 
"coldest". 
 
2) Thermostat is malfunctioning and makes the compressor running continuously 
Analysis of Trouble 
When the thermostat doesn't work normally, it will make the compressor run continuously, and 
hence very low temperature will be achieved in the refrigerator. The fault is generally due to the fact 
that the contacts of the thermostat cannot be released. 
Remedy 
Dismantle the thermostat and make a through checkup, if it is totally out of functioning, replace it 
with a new one. 
 
3) Evaporation temperature is too high in refrigerating system, resulting in lower refrigerating 
capacity and hence continuous running of compressor 
Analysis of Trouble 
Leakage of refrigerant and clogging in a refrigerating system will directly affect its refrigerating 
capacity. Due to the reduction in its refrigerating capacity, the refrigerator temperature cannot reach 
its rated value, the thermostat won't work, thus the compressor runs continuously. When the 
evaporation temperature in the system is too high, the temperature sensing agent in the 
temperature sensor is also hotter, therefore, the thermostat is unable to cut off the power supply to 
the compressor and stop it. 
Remedy 
If it has been found that the refrigerant in the system is insufficient in quantity, recharge it with 
refrigerant. In case clogging occurs, disassemble the part where it is blocked. If the evaporation 
temperature is too high, settle this problem with an appropriate quantity of refrigerant. 
 
4) No stoppage of compressor due to damaged heat-insulation layer inside case body and/or door 
seal Analysis of Trouble 
When the heat-insulation layer inside the case body deteriorates or the door seal is not closely 
touches the door frame, the temperature in the refrigerator will rise and makes the compressor 
running continuously. Remedy Check the heat-insulation layer for its damaged parts, repair it to 
improve its heat-insulation property. If the door has deformed or the door seal is not tightly sealed 
against the case body, repair them, respectively. 
 
5) Too much food is placed in the refrigerator, or is placed too densely, resulting in poor ventilation 
or poor conditions for temperature sensing, and hence no stoppage of the compressor. 
 
6) Too high ambient temperature, poorer ventilation and heat dissipation make the compressor 
running without stop. 
F. Electric leakage of refrigerator 
 
 
23 
 
1) Slight electric leakage 
Electric insulation has deteriorated due to being affected with damp, thus resulting in slight electric 
leakage. 
 
2) Serious electric leakage 
Refrigerator case has become live due to faults occurred in some electric devices or the erroneous 
wiring in installing power cord plug or outlet by the user. This is very dangerous. 
 
3) Electric leakage test 
 
a) Slight electric leakage 
A tingle sense will be experienced as soon as you touch the metal parts of the refrigerator with your 
hand .When you test them with a test pencil, its neon lamp will come on .In that case, the first thing 
you need to do is to determine whether the grounding is perfect .If the grounding is no problem, turn 
off the refrigerator immediately, then check the insulation of electric circuits with an multimeter. 
 
b) Serious electric leakage 
Never touch the case body of the refrigerator, its door handle or other metal parts with your 
hand .Test the refrigerator with a test pencil, it will light up intensively ;measure the resistance 
between the power cord plug and the case body with an avometer, the reading will be zero (0
); in 
the worst case, the fuse will be blown .Check the 3-prong outlet to see whether the live wire and the 
null line are inversely connected, this makes the ground protection lead-out from the power cord 
plug being connected to the live wire .Another possibility is that the live wire and null line of the 
outdoor power supply circuit have been inversely connected accordingly, this makes the null line 
become a live wire . 
 
 
G .Stronger vibration and loader noise 
1) 
Refrigerator placed improperly 
a) Uneven ground 
Uneven ground will cause there frigerator to be placed unsteadily, causing stronger vibration and 
noise during its operation . 
 
b) Leveling screws not properly adjusted 
If the leveling screws on refrigerator legs have not been adjusted properly, vibration and noise will 
still occur even if the refrigerator has been placed on a level ground. 
 
2) 
Abnormal noise from compressor 
Three suspended spring inside the compressor case are out of balance, and strike against the case, 
moreover, the wear of compressor parts may cause noise sometimes. 
 
3) 
Resonance of tubing and loosening of parts 
Improper and compact laying of tubes or the loosening of parts may cause vibration and noise. 
 
 
 
 
24 
4) Inspection method 
To find the sources of noise, press the vibration spot with your hand while the refrigerator is in 
operation and listen attentively whether the vibration becomes weake or vanishes. If the refrigerator 
has not been levelly placed, put a level meter on its top table and adjust the leveling screws on its 
legs .In case noise occurs from the compressor, strike different locations on the side surface of its 
case using a rubber hammer or hand hammer with a wood block in-between so as to determine 
whether the suspended springs are out of balance or being seized   
 
 
 
ERROR CODE ON CONTROL PANEL 
Analyses: 
User  may  have  changed  the  original  preset  parameters  of  the  refrigerator.  So  the  parameters  of  the  refrigerator 
Chamber have been increased. It means the parameters are now out of the Adjustable Range. 
 
Pressing the Number Keys can change the original preset parameters. Contents and Range are as below:   
 
Display  on 
Panel 
Meanings of the Display 
Original 
preset 
parameters 
Adjustable 
Range 
for 
parameters 
C1 
Fridge  Chamber  parameters 
(on) 
-30~30 
C2 
Fridge  Chamber  parameters 
(off) 
12 
2~31 
d1 
Freezer Chamber parameters 
(on) 
-1 
-30~30 
d2 
Freezer Chamber parameters 
(off) 
2~31 
 
So  if  user  changes  the  original  preset  parameters,  and  these  parameters  are  out  of  the  effective  range,  the 
refrigerator  chamber  will  not  work  as  normal.  And  if  you  change  the  parameters  into  the  adjustable  range  (see 
above sheet), the machine will return to work.   
 
Meanings of Error Code: 
 
Error Code 
 
E0  in  Fridge  area  on 
display 
Sensor  fault  in  Fridge 
chamber 
E0  in  Freezer  area  on 
display 
Sensor  fault  in  Freezer 
chamber 
E1  in  Freezer  area  on 
display 
Evaporator’s  Sensor  fault 
in Freezer chamber 
EC 
Communication failures 
E0 E1 E2 
Sensor 
fault 
and 
Evaporator’s Sensor fault   
 
Page of 40