Panasonic NR-BN30PGW / NR-BN30PGB / NR-BN30PS1 / NR-BN30QGW / NR-BN30QGB / NR-BN30QW1 / NR-BN30QS1 Service Manual ▷ View online

 
 
Maintenance Service and Trouble Shooting 
 
4. The compressor doesn't work 
 
 
 
                                                    YES 
 
 
                                                                                                        NO 
 
 
 
                                                                                                                                                                                        NO 
                                                        YES 
                                                                            YES 
                                                                         
 
                                                                                              NO 
 
 
                                                                                                                                                                                                                    YES   
                                                    YES 
 
 
 
 
                                                                                                        NO 
   
 
                                                      YES 
                                                       
 
                                                                                                              NO 
                                                                                                                   
 
 
 
                                                      YES 
 
 
 
 
The compressor doesn't work. 
Is the interior 
light on when 
door is opened? 
Is  the  power  of 
220V output? 
Do  the  compressor 
have 220V output? 
Check and repair compressor 
and accessory 
Is the ambient 
temperature 
low than 16
°
Check the power 
source and power 
Check the 
thermostat is 
correct? 
Repair 
Adjust and instruct 
consumer how to use 
Check and repair the 
control panel. 
Check all cords and 
power cords
 
 
 
10 
Maintenance Service and Trouble Shooting 
 
5. Normal Phenomena
—Not Troubles for Refrigerators 
In a domestic refrigerator, there is not only a complicated electric control system, but also a 
refrigerating system that is difficult to discern whether it is in a good working condition. Both the 
systems are related and affect each other. If a certain part of a refrigerator works abnormally .Its 
refrigerating efficiency will decrease, operation properties will become unstable ,or even it cannot be 
used normally for those serious cases. 
 
Refrigerators are generally of larger volume, once troubles appear ,to send them to a service 
department is really a tough thing ,if such is the case ,the user will always be in 
suspense ,sometimes ,normal phenomena will be erroneously regarded as 
troubles .Therefore ,before we deal with the topics of frequently occurring troubles of refrigerators 
and their remedies ,we should firstly give a brief account of some normal 
phenomena which are not troubles .In case any one of such phenomena occurs ,there is no need to 
worry about it ,and the user can use it at total ease . 
 
1). When the compressor of a refrigerator has just stopped running, a rumbling sound can be heard 
from inside its evaporator .This is a sound caused by the flowing of refrigerant in the evaporator 
tubing .Because the pressure difference is still greater after the compressor has just stopped 
running ,the refrigerant will flow for a certain time , therefore ,this sound is a normal phenomenon. 
 
2). A click sound can often be heard from the refrigerator. This is a normal sound produced by the 
pull-in or release of the armature of a current deadweight start relay when starting the 
compressor .The compressor motor will produce a slight and uniform sound while it is running. This 
sound is not easy to be heard in the daytime, but of course it can be heard distinctly at night. 
 
3). The compressor consists of an electric motor and a compressing apparatus .During its normal 
operation ,the motor's stator core and windings will rise to a temperature in the range of 100°
C~110°C ,and the temperature of the piston and cylinder of the compressing mechanism can also 
reach as above 100°C due to the heat produced when compressing refrigerant .Most of the heat 
radiates to the air through the compressor casing ,therefore ,its casing is generally at a temperature 
between 85°C ~90°C ,it is very hot ,particularly in summer when the ambient temperature is 
higher .All these are normal phenomena . 
 
4). For the direct cooling refrigerator, a kind of irregular crack sound can be often heard when the 
compressor is running for a certain period of time or has just stopped its running. This sound is 
caused by the stress relief due to expansion and contraction when temperature changes, and will 
not affect the normal application of refrigerator.
 
 
 
 
11 
Maintenance Service and Trouble Shooting 
6. Common Troubles in Refrigerators and Their Remedies 
Causes for troubles occurring in refrigerators are closely related to the quality of components and 
workmanship in assembling by manufacturers as whether refrigerators are properly used and 
maintained .The parameters generally used to express the working conditions of a refrigerator 
include the temperature inside the refrigerator ,operation rate ,electric power consumption ,noise 
level ,and other functional indexes .If any one of these parameters is beyond its permissible 
range ,this indicates that there is a fault or trouble in the refrigerator . 
During the whole service life of a refrigerator ,the probability of troubles occurring within a union time 
is called its failure rate .Making a comparison between the control circuit system of a refrigerator and 
its refrigerating system ,we can find that the failure rate of the former is higher ,and that of the 
thermostat is the highest . In troubleshooting ,the first thing you must do is to determine where the 
trouble comes from --- the control system or the refrigerating system .There is general no trouble 
indicating instrument mounted on the domestic refrigerator ,locations and natures of troubles should 
be determined according to their respective features ,therefore ,experience in servicing is very 
important to troubleshooting. Service technicians with rich experience can correctly locate them and 
take reasonable remedy measures based on their comprehensive analysis of trouble characteristics 
as well as operating conditions for various kinds of refrigerators. 
 
Three Essentials for Checkup 
1) Look 
a) Check the tubing of refrigerating system for cracks and various welding points for leaks; if leakage 
occurs ,an oil stain can be seen definitely . 
b) Check the suction and exhaust pressure values (high pressure and low pressure) of compressor 
to see whether they are normal. 
c) Check the conditions of frost attached to its evaporator and gas return tube .It is abnormal if frost 
has formed on part of the evaporator or there is no frost attached to it. 
d) Pay attention to the speed of temperature drop inside freezer compartment .It is abnormal if the 
speed of temperature drop is obviously slower than the corresponding normal speed. 
e) Check the environment to see if the whether is suitable for placing a refrigerator. 
f)    Check refrigerator door seal, case, table surface and heat insulation 
g) Look at the main control board to ascertain if various indication states are normal. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
12 
2) Listen 
 
a) Listen to the noises produced when the compressor is running hums from a fully enclosed 
aggregate unit is the sound caused by overload indicating that the motor cannot be started normally, 
meanwhile ,a clattering sound can be heard from inside the start relay ,which is produced because 
the start contacts cannot be released normally .A whistling sound is caused by the high pressure 
gas flowing out of the crack of the pressure tube inside the compressor ,and clucks are the sound of 
striking after the suspended spring inside the compressor has broken . 
During the normal operation of compressor ,a slight and uniform hum sound due to undulation of 
electric current can be heard generally ,this is a normal phenomenon .However ,if it sounds like 
"tong ,tong 
",i.e., an impact sound inside the compressor ,this means that a large quantity of wet 
vapour of refrigerant or refrigerating oil has come into the compressor cylinder ;if it sounds like 
"dang ,dang
", a striking sound of metal parts inside the compressor ,this means that some moving 
parts have loosened (note to differentiate this sound from those formed during starting or stopping 
the compressor). 
 
b) Listen to the sound caused by the flowing of gas in the evaporator. Open the refrigerator door 
while the compressor is in operation, incline your ear and listen attentively the gas   
flow sound inside the evaporator .If it sounds like gentle whistling accompanied by a sound similar to 
water flowing, this is the sound produced by the normal circulation of refrigerant within the 
evaporator .In case only the gas flowing sound can be heard and there is no water flowing 
sound ,this indicates that the refrigerant has already percolated .If neither the flowing sound nor the 
gas sounds from the evaporator can be heard ,this means that the filter or capillary has been 
clogged . 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 