5.2.
Program Details
5.3.
Program Details with Half Load Defection
Full Load / Half
Load
Programmes
Programme
Set Temperature
Available
Temperature
Program
Duration (min)*
Energy (kwh)*
Water
Consumption (L)
Full Load
Cotton Eco
40
Cold - 60
185
0,99
47
Cotton Eco
60
Cold - 60
200
1,02
47
Half Load
HL Cotton Eco
40
Cold - 60
160
0,58
44
HL Cotton Eco
60
Cold - 60
165
0,70
44
NA-106VC5WRU
10
5.4.
Child Lock
Activation
Press the fourth function button for 4-5 seconds.
The Child Lock Symbol is appears on the LCD display.
Deactivation
Press the fourth function button for 4-5 seconds.
The Child Lock Symbol is deleted on the lcd display.
6 Test Mode
6.1.
Autotest
After selecting spin speed to max, select the program 3
While pressing ‘Time Saver’button, change position of the third to second, and release the ‘Time Saver’ button immediately.
Autotest starts.
NA-106VC5WRU
11
NA-106VC5WRU
12
7 Service Mode
7.1.
Service Autotest
1. After selecting spin speed to max, select program 3
2. While pressing the T
°
C
button, change program position
third to second, and release the T
°
C
button within 1 sec-
ond.
3. During test “SAU” is visualized on display :
The test steps are as below ;
Step 1:
Step 1:
Selector Program 1
will be “HEATER ON”
Before heating it should take water till first level frequency
then start heating.
then start heating.
Heater will be on max. 8 minutes after this 8 minutes if the
temp. doesn’t change more than 2
temp. doesn’t change more than 2
°C then it will give NTC
failure. (E05).
Or if the NTC connection is broken then it should give again
E05 NTC failure.
E05 NTC failure.
At the end of heating, “SAU” visualization should make slow
blink to indicate that the step is over.
blink to indicate that the step is over.
Note:
If user changes the selector position, machine will do what
is defined for the new selected position.
is defined for the new selected position.
Step 2:
Selector Program 2
will
be “PUMP ON”
Temperature will be measured, if it is higher than 50
°C, it
should take 60 sec. cooling water, and then make “Drain + 5
sec.
sec.
At the end of pump activation, “SAU” visualization should
make slow blink to indicate that the step is over.
make slow blink to indicate that the step is over.
Step 3:
Selector Program 3
will be 15 minutes test
program.
So, time for selector position 3 is 15 minutes.
At the end of 15 minutes test program “END” is visualized
and door is unlocked. During test pressing other buttons
makes no change.
and door is unlocked. During test pressing other buttons
makes no change.
LD1 Start / Pause button LED
→ ON
LD9 Door Lock LED
→ When the door is unlocked it will be off
Display
→ “END”
15 Minutes Test Program
Total water consumption : 30 L (14L Main Wash, 16L Rinse)
Total duration : 15 min. (8 min Main Wash, 7 min Rinse)
Total 53 r/min motor movement : 6.5 min.
(4.5 min Main Wash , 2 min Rinse)
(4.5 min Main Wash , 2 min Rinse)
Heating: 1.5 min during Main Wash
Spinning: 400 r/min (After Main Wash) 800 r/min (After
Rinse)
Rinse)
Number of Rinses : 1
LD1 (Start / Pause Button LED)
→
ON
LD9 (Door Lock LED)
→
ON (in 30 sec)
Display
→