Panasonic UF-590 / UF-790 Service Manual ▷ View online
121
4.6.3.
Dialing Problems
START
END
No
Yes
Does the unit proceed to
Phase B?
Phase B?
1. Set documents on the ADF correctly.
4. Refer to Sect. 4.6.
3. The called party is busy.
2. Check the telephone line connection.
Are you using One-Touch
or ABBR dialing?
or ABBR dialing?
Are you using direct dialing?
No
Yes
Check the registered telephone number.
Is the Monitor Volume
too loud or too low?
too loud or too low?
No
Yes
Check the dialed telephone number.
No
Yes
Adjust the monitor volume by pressing the
"/\" button or "\/" button.
"/\" button or "\/" button.
122
4.6.4.
Transmission Problems
START
END
Yes
No
Does the ID display?
1. No ID function at the remote unit.
2. The ID is not set for the remote unit.
2. The ID is not set for the remote unit.
Does the Verification Stamp
operate?
operate?
Is the copy quality OK?
Yes
No
No
1. Set "STAMP=ON"
2. Check CN3 (SC PCB).
3. Replace the Stamp Solenoid.
4. Replace the SC PCB.
2. Check CN3 (SC PCB).
3. Replace the Stamp Solenoid.
4. Replace the SC PCB.
Any other problems?
Yes
No
Make a copy and refer to Sect. 4.4.16
Yes
See Sect. 4.3 (Troubleshooting with the
Information Codes).
Information Codes).
123
4.6.5.
Reception Problems
START
END
Yes
No
Does the machine answer
the Ringing signal?
the Ringing signal?
1. Set "RCV = AUTO"
2. Check that all covers are closed firmly.
3. Check the telephone line connection.
4. Check the Ringer Timing or DRD setting.
5. Check the recording paper path.
6. Check CN18 (SC PCB) and CN28 and
29 (MJR PCB).
7. Replace the MJR PCB.
8. Replace the SC PCB.
2. Check that all covers are closed firmly.
3. Check the telephone line connection.
4. Check the Ringer Timing or DRD setting.
5. Check the recording paper path.
6. Check CN18 (SC PCB) and CN28 and
29 (MJR PCB).
7. Replace the MJR PCB.
8. Replace the SC PCB.
Is the received copy OK?
Any other problems?
Yes
No
Make a copy and refer to Sect. 4.4.14.
Yes
No
See Sect. 4.3 (Troubleshooting with the
Information Codes).
Information Codes).
124
4.6.6.
Polling Problems
Note:
No-check Mode means that password is not set.
START
END
Yes
No
Is Polling reception OK?
1. Set the same polling password as the other party
is using.
2. Check the password of the remote unit.
is using.
2. Check the password of the remote unit.
Is Polling transmission OK?
Any other problems?
Yes
No
1. Set the polling password or no - check mode.*
2. Check the password of the remote unit.
2. Check the password of the remote unit.
Yes
No
See Sect. 4.3 (Troubleshooting using information codes).
Click on the first or last page to see other UF-590 / UF-790 service manuals if exist.