DOWNLOAD Panasonic UF-590 / UF-790 Service Manual ↓ Size: 15 MB | Pages: 127 in PDF or view online for FREE

Model
UF-590 UF-790
Pages
127
Size
15 MB
Type
PDF
Document
Service Manual
Brand
Device
Fax / LASER
File
uf-590-uf-790.pdf
Date

Panasonic UF-590 / UF-790 Service Manual ▷ View online

89
4.3.1.
Information Codes: 400, 420
START
400
END
END
Enable the monitor 
speaker. (Refer to Sect. 
5.2 Parameter No. 008)
Does the remote unit 
repeat the 300 bps 
signal every 3 sec.?
1. Refer to Sect. 4.6.
2. Check the remote unit.
(Remote unit is defective)
    (Remote unit is defective)
2. Check the telephone
1. Check the remote unit.
    number to the remote unit.
Perform a transmission 
test to the remote unit in 
question.
Does the remote unit 
send the CED and 300 
bps Fax signal ?
Is transmission to the
reference unit successful?
1. Replace the MJR PCB.
2. Replace the SC PCB.
Does the trouble still occur?
Yes
Yes
Yes
No
No
No
Yes
No
START
420
END
2. Check the remote unit.
1. Misdialed call.
    (Remote unit is defective)
3. Refer to Sect. 4.6.
Check the line 
connection from the wall 
jack to the "Line" on the 
MJR PCB.
Is reception from a 
reference unit 
successful?
Replace the SC PCB.
Yes
No
90
4.3.2.
Information Codes: 401, 402, 422
Replace the SC PCB.
Check the remote unit in question.
(Remote unit is defective)
Is Communication with the
reference unit successful?
No
Yes
402, 422
END
Is the ID Number programmed
into your machine?
Is the Receiving unit set up for
Selective Receive?
Program the ID Number.
Yes
No
START
401
Is the Receiving unit set up for
Password Reception?
Are you sending a Confidential
Mail?
Check the Selective Receive
settings at the receiving unit.
Yes
No
No
No
Program the Receive Password
to match the receiving unit.
(Fax Parameter No. 44)
Yes
Check with the receiving end,
the mailboxes may be full.
Yes
Are you sending a document
by Relayed Transmission?
No
Check the Relayed Transmission
settings at the Relay Station.
Yes
END
 START
91
4.3.3.
Information Codes: 404, 405, 407
START
END
Is communication with reference
unit successful?
Change Function Parameter #010:
Reduce Tx Attenuation Level
Yes
No
Yes
No
Change Function Parameter #017:
Reduce Tx Modem Speed
Does the problem still occur?
1. Replace the MJR PCB.
2. Replace the SC PCB.
Does the problem still occur?
Change Function Parameter #025:
Communication Startup to 2nd
Does the problem still occur?
Change Funciotn Parameter #014:
Increase G3 Tx Equalization
Does the  problem still occur?
END
Does the problem still occur?
Check the telephone line condition.
Does the problem still occur?
(Recording paper may have run
Check the remote unit.
out or paper may have jammed.)
Refer to Sect. 4.6.
Yes
No
Yes
No
Yes
Yes
No
No
Yes
No
92
4.3.4.
Information Code: 416
START
END
Is communication with the
reference unit successful?
Change Function Parameter 
#011: Reduce Rx Sensitivity 
Level
Yes
No
Yes
No
Change Function Parameter
#023: Increase Training 
Check Period
Does the problem still occur?
1. Replace the MJR PCB.
2. Replace the SC PCB.
Refer to Sect. 4.6.
Does the problem still occur?
Change Function Parameter 
#013: Increase G3 Rx 
Equalization
Does the problem still occur?
END
Does the problem still occur?
Yes
No
No
Yes
No
Yes
Check the telephone line 
condition.
Page of 127