Panasonic KX-MB263RU / KX-MB263UA (serv.man7) Service Manual ▷ View online
89
KX-MB263RU-B/KX-MB263UA-B
11.2.6.3. CALL SERVICE 3
"CALL SERVICE 3" means that the temperature of the fuser does not rise up to or exceed a constant temperature.
The temperature is monitored with the thermistor inside the fuser and detected with the voltage input into IC 300-D19.
The temperature is monitored with the thermistor inside the fuser and detected with the voltage input into IC 300-D19.
* When Call Service 3 is occurred, the cause can be distinguished by service mode 655.
Refer to P.86 for details.
Refer to P.86 for details.
90
KX-MB263RU-B/KX-MB263UA-B
11.2.6.4. CALL SERVICE 4
"CALL SERVICE 4" means that the FAN does not run or the running of the FAN cannot be detected normally.
The running of the FAN is detected by IC300-AC20 and W24pin. "CALL SERVICE 4" is displayed when it detects NG three times
continuously.
After repairing, copy three times.If “CALL SERVICE 4 “ is displayed, check again.
The running of the FAN is detected by IC300-AC20 and W24pin. "CALL SERVICE 4" is displayed when it detects NG three times
continuously.
After repairing, copy three times.If “CALL SERVICE 4 “ is displayed, check again.
91
KX-MB263RU-B/KX-MB263UA-B
11.2.6.5. CALL SERVICE 5
“CALL SERVICE 5” means that Engine DC motor’s rotation detection signal (LD) does not become Low.
92
KX-MB263RU-B/KX-MB263UA-B
11.2.6.6. CALL SERVICE 6
“CALL SERVICE 6” indicates that abnormal charge voltage is output from the high voltage unit.