101
KX-MB1500RU/KX-MB1520RU/KX-MB1530RU
10.1.2. Button Code Table (KX-MB1500 ONLY)
10.1.3. Button Code Table (KX-MB1520/KX-MB1530 ONLY)
102
KX-MB1500RU/KX-MB1520RU/KX-MB1530RU
10.1.4. Print Test Pattern
1. NO.01
2. NO.06
3. NO.03
• These print test patterns are just image printing, and differ-
ent from actual ones.
• When it is required to judge the print quality, compare with
the printing of a nondefective machine.
103
KX-MB1500RU/KX-MB1520RU/KX-MB1530RU
11 Service Mode
The programming functions are used to program the various features and functions of the machine, and to test the machine.
This facilitates communication between the user and the service man while programming the unit.
11.1. Programming and Lists
11.1.1. Operation
There are 2 basic categories of programming functions, the User Mode and the Service Mode. The Service Mode is further broken
down into the normal and special programs. The normal programs are those listed in the Operating Instructions and are available to
the user. The special programs are only those listed here and not displayed to the user. In both the User and Service Modes, there
are Set Functions and Test Functions. The Set Functions are used to program various features and functions, and the Test Func-
tions are used to test the various functions. The Set Functions are accessed by entering their code, changing the appropriate value,
then pressing the SET key. The Test Functions are accessed by entering their code and pressing the key listed on the menu. While
programming, to cancel any entry, press the STOP key.
Note:
When changing the set values on the service function table, they should not be set beyond the local regulation.
Follow the laws and regulations of your area.
11.1.2. Operation Flow
104
KX-MB1500RU/KX-MB1520RU/KX-MB1530RU
11.1.3. Service Function Table (KX-MB1500 ONLY)
11.1.4. Service Function Table (KX-MB1520/KX-MB1530 ONLY)
Code
Function
Set Value
Effective 
Range
Default
Remarks
529
Call Service Clear
550
Memory clear
Refer to Memory Clear Specification (P.106).
551
ROM check
See Test Functions (P.99).
555
Scanner test
See Test Functions (P.99).
556
Motor test
0
See Test Functions (P.99).
557
LED test
See Test Functions (P.99).
558
LCD test
See Test Functions (P.99).
561
KEY test
See Test Functions (P.99).
628
H.V.P.S. check
See Test Functions (P.99).
639
LSU test
See Test Functions (P.99).
655
Cause Distinction Code of Call Service 3
See  CALL SERVICE Troubleshooting Guide
(P.130).
677
FAN test
See Test Functions (P.99).
710
Memory clear except History data
Refer to Memory Clear Specification (P.106).
815
Sensor check
See Test Functions (P.99).
852
Print test pattern
See Test Functions (P.99).
853
Top margin
1~11
6
 ---------- 
854
Left margin
1~11
6
 ---------- 
880
History list
See  History (Example of a printed out list)
(P.113).
Code
Function
Set Value
Effective 
Range
Default
Remarks
501
Pause time set 
X 100 msec
001~600
035
 ---------- 
503
Dial speed select 
1:10 pps 
2:20 pps
1, 2
1
 ---------- 
507
V34 transmission start speed 
0: Disable
1: 33.6
2: 31.2
3: 28.8
4: 26.4
5: 24.0
6: 21.6
7: 19.2
8: 16.8
0~8
1
If the code 527 is set at 2, the code 507 and 508
work.
508
V34 reception start speed 
0: Disable
1: 33.6
2: 31.2
3: 28.8
4: 26.4
5: 24.0
6: 21.6
7: 19.2
8: 16.8
0~8
1
If the code 527 is set at 2, the code 507 and 508
work.
514
Bell signal detect time 
X 100msec
1~9
6
 ---------- 
520
CED frequency select
1:2100 Hz
2:1100 Hz
1, 2
1
See How To Output The Journal Report (P.163).
521
International mode select 
1:ON / 2:OFF 1, 2
1
See How To Output The Journal Report (P.163).
522
Auto standby select
1:ON / 2:OFF 1, 2
1
The resolution reverts to the default when transmis-
sion is complete.
523
Receive equalizer select
1: 0 km
2: 1.8 km
3: 3.6 km
4: 7.2 km
1~4
1
Set RX equalizer to automatic mode.
524
Transmission equalizer select 
1: 0 km
2: 1.8 km
3: 3.6 km
4: 7.2 km
1~4
1
527
V.8 function select 
1:OFF / 2:ON 1, 2
2
529
Call Service Clear
550
Memory clear
Refer to Memory Clear Specification (P.106).