DOWNLOAD Panasonic DMC-G10KPP / DMC-G10KEB / DMC-G10KEC / DMC-G10KEG / DMC-G10KGC / DMC-G10KGD / DMC-G10KGH / DMC-G10KGT / DMC-G10KGK / DMC-G10KGN / DMC-G10WGC / DMC-G10WGH / DMC-G10WGN Service Manual ↓ Size: 8.35 MB | Pages: 68 in PDF or view online for FREE

Model
DMC-G10KPP DMC-G10KEB DMC-G10KEC DMC-G10KEG DMC-G10KGC DMC-G10KGD DMC-G10KGH DMC-G10KGT DMC-G10KGK DMC-G10KGN DMC-G10WGC DMC-G10WGH DMC-G10WGN
Pages
68
Size
8.35 MB
Type
PDF
Document
Service Manual
Brand
Device
Digital Camera / DIGITAL CAMERA/LENS KIT/DOUBLE ZOOM LENS KIT
File
dmc-g10kpp-dmc-g10keb-dmc-g10kec-dmc-g10keg-dmc-g1.pdf
Date

Panasonic DMC-G10KPP / DMC-G10KEB / DMC-G10KEC / DMC-G10KEG / DMC-G10KGC / DMC-G10KGD / DMC-G10KGH / DMC-G10KGT / DMC-G10KGK / DMC-G10KGN / DMC-G10WGC / DMC-G10WGH / DMC-G10WGN Service Manual ▷ View online

41
9.2.
Disassembly and Assemble Procedure for the Lens (H-FS014042)
It is recommended dealing with clean box, to keep maintaining the dustproof environment.
(Refer to “8.2. Clean Box” section of this service manual for details.)
Important:
1. When servicing the enclosure part (refer to Fig. K1), it must be performed inside of satisfied clean level.
(Satisfied clean level: Less than class 10,000 (Federal Standard 209D))
As for procedure, refer to the “11 Maintenance” for detailes.
2. To minimize the possibilities/risk of getting the dust/dirt on the lens surface, keep covering the lens unit with lens caps (front &
rear), other than necessary cases.
3. Do not touch the surface of the lens glasses with your fingers.
4. Blow off the dust on the surface of the lens with a blower brush.
5. Use lens cleaning KIT (BK)(VFK1900BK).
Proceed disassemble/assemble, by referring the following table and Fig. K1.
NOTE:
1. When installing the screws, be sure to use the torque driver (RFKZ0456) and tighten the screws with specified torque, men-
tioned on the above table.
2. The Ref.B213 is no need to remove/install for disassembly and assembly.
If necessary, use VFK1390 (small driver) when screwing it.
Interchangeable Lens (H-FS014042)
(Fig. K1)
42
9.3.
Disassembly and Assemble Procedure for the Lens (H-FS045200)
It is recommended dealing with clean box, to keep maintaining the dustproof environment.
(Refer to “8.2. Clean Box” section of this service manual for details.)
Important:
1. When servicing the enclosure part (refer to Fig. W1), it must be performed inside of satisfied clean level.
(Satisfied clean level: Less than class 10,000 (Federal Standard 209D))
As for procedure, refer to the “11 Maintenance” for detailes.
2. To minimize the possibilities/risk of getting the dust/dirt on the lens surface, keep covering the lens unit with lens caps (front &
rear), other than necessary cases.
3. Do not touch the surface of the lens glasses with your fingers.
4. Blow off the dust on the surface of the lens with a blower brush.
5. Use lens cleaning KIT (BK)(VFK1900BK).
Proceed disassemble/assemble, by referring the following table and Fig. W1.
NOTE:
1. When installing the screws, be sure to use the torque driver (RFKZ0456) and tighten the screws with specified torque, men-
tioned on the above table.
2. The Ref.B309 is no need to remove/install for disassembly and assembly.
3. Use small driver (VFK1390) when removing/tighten the B308.
Interchangeable Lens (H-FS045200)
(Fig. W1)
43
10 Measurements and Adjustments
10.1. Matrix Chart for Replaced Part and Necessary Adjustment
The relation between Replaced part and Necessary Adjustment is shown in the following table.
When concerned part is replaced, be sure to achieve the necessary adjustment(s).
As for Adjustment condition/procedure, consult the “Adjustment Manual” which is available in Adjustment software.
NOTE:
After adjustments have been terminated, make sure to achieve “INITIAL SETTINGS”.
After updates it to the latest firmware, the adjustment is executed.
*1
• Inspect it, not only corresponding part is replaced, but also camera body is shocked and/or dropped. 
• The DMC-G1/DMC-GH1/DMC-GF1 unit (marketed commodity: operates normal) etc. in accordance with the Micro Four Thirds
System and normal zoom lens H-FS014045 (marketed commodity) are necessary.
• Refer to the adjustment instruction in the adjustment software for details.
*2 NOTE: (When exchange the MAIN P.C.B.)
• Correspond by either the following when exchange the MAIN P.C.B. unavoidably by destruction and damage etc. of MAIN
P.C.B..
1. When it can turn on power, and the adjustment software can communicate with the camera body:
• Before replacing, proceed the FLASH-ROM data backup from the unit. After replacing, overwrite the FLASH-ROM data with
backup data from the unit, before proceeding the main body adjustment.
2. When it cannot turn on power, or the adjustment software cannot communicate with the camera body:
• The readjustment of mount box unit etc. are necessary.
• Refer to the adjustment instruction in the adjustment software for details.
44
*3 NOTE: (After exchange the mount box unit)
• Execute the resolution inspection by the comparison with the standard model (DMC-G1K etc.: operates normal). 
• Refer to the adjustment instruction in the adjustment software for details.
*4
• Confirm self recording/playback motion picture of AVCHD mode by the LCD.
• Confirm it on the TV with HDMI socket when repair HDMI relation.
* There are no LCD/LVF adjustment model.
Page of 68
Display

Click on the first or last page to see other DMC-G10KPP / DMC-G10KEB / DMC-G10KEC / DMC-G10KEG / DMC-G10KGC / DMC-G10KGD / DMC-G10KGH / DMC-G10KGT / DMC-G10KGK / DMC-G10KGN / DMC-G10WGC / DMC-G10WGH / DMC-G10WGN service manuals if exist.