6 Service Mode
6.1.
Error Code Memory Function
1. General description
This unit is equipped with history of error code memory function, and can be memorized 16 error codes in sequence from the                   
latest. When the error is occurred more than 16, the oldest error is overwritten in sequence.
The error code is not memorized when the power supply is shut down forcibly (i.e.,when the unit is powered on by the battery, 
the battery is pulled out) The error code is memorized to FLASH ROM when the unit has just before powered off.
2. How to display
The error code can be displayed by ordering the following procedure:
• Preparation:
1. Attach the Battery to the unit.
Note: 
*Since this unit has built-in memory, it can be performed without inserting SD memory card.
*Select the mode other than "3D" mode (such as normal picture / iA / Sports / Snow / SCN)
      to display the error code.
• Step 1. The temporary cancellation of "INITIAL SETTINGS":
While keep pressing "UP of Cursor button" and MOTION PICTURE button simultaneously, turn the Power on.
• Step 2. Execute the error code display mode:
Press the "LEFT of Cursor button", MENU/SET button and MOTION PICTURE button simultaneously.
The display is changed as shown below when the above buttons are pressed simultaneously.
Normal display 
→ Error code display → CAMERA INFO → Normal display → .....
23
3. Error Code List
The error code consists of 8 bits data and it shows the following information.
Attribute Main item Sub item
Error code
Contents (Upper)
Error Indication
High 4bits Low 4 bits
Check point (Lower)
Detecting
device
Part/Circuit
LENS
Lens drive OIS
18*0
1000
PSD (X) error. Hall element (X axis) position detect 
error in OIS unit.
OIS X
LENSu NG
OIS Unit
2000
PSD (Y) error. Hall element (Y axis) position detect 
error in OIS unit.
OIS Y
OIS Unit
3000
GYRO (X) error. Gyro (IC7101) detect error on Main 
P.C.B.
GYRO X
GYRO NG
IC7101 (Gyro element) or IC6001 (VENUS ENGINE)
4000
GYRO (Y) error. Gyro (IC7101) detect error on Main 
P.C.B.
GYRO Y
IC6302 (Gyro element) or IC6001 (VENUS ENGINE)
5000
MREF error (Reference voltage error).
OIS REF
LENSSd/DSP 
NG
IC9101 (LENS DRIVE) or IC6001 (VENUS ENGINE)
6000
Drive voltage (X) error.
OISX REF
LENSu/LENS 
FPC
LENS Unit, LENS flex breaks, IC6001(VENUS 
ENGINE) AD value error, etc.
7000
Drive voltage (Y) error.
OISY REF
LENS Unit, LENS flex breaks, IC6001(VENUS 
ENGINE) AD value error, etc.
Zoom
0?10
Collapsible barrel Low detect error
(Collapsible barrel encoder always detects Low.)
ZOOM L
ZOOMm/
LENSu
Mechanical lock, FP9003-(2) signal line or IC6001 
(VENUS ENGINE)
0?20
Collapsible barrel High detect error
(Collapsible barrel encoder always detects High.)
ZOOM H
Mechanical lock, FP9003-(2) signal line or IC6001 
(VENUS ENGINE)
0?60
The zoom position jump is detected due to the 
impact (i.e. drop.) to the camera occurs.
(No indication) (No indication)
Lens unit
Focus
0?01
HP High detect error
(Focus encoder always detects High, and not 
becomes Low)
FOCUS L
LENS FPC/
DSP
Mechanical lock, FP9003-(40) signal line or IC6001 
(VENUS ENGINE)
0?02
HP Low detect error
(Focus encoder always detects Low, and not 
becomes High)
FOCUS H
Mechanical lock, FP9002-(40) signal line or IC6001 
(VENUS ENGINE)
Lens
18*1
0000
Power ON time out error.
LENS DRV
LENSu
Lens drive system
18*2
0000
Power OFF time out error.
Lens drive system
Adj.History OIS
19*0
2000
OIS adj. Yaw direction amplitude error (small)
OIS ADJ
OIS ADJ
3000
OIS adj. Pitch direction amplitude error (small)
4000
OIS adj. Yaw direction amplitude error (large)
5000
OIS adj. Pitch direction amplitude error (large)
6000
OIS adj. MREF error
7000
OIS adj. time out error
8000
OIS adj. Yaw direction off set error
9000
OIS adj. Pitch direction off set error
A000
OIS adj. Yaw direction gain error
B000
OIS adj. Pitch direction gain error
C000
OIS adj. Yaw direction position sensor error
D000
OIS adj. Pitch direction position sensor error
E000
OIS adj. other error
24
1) About "*" indication:
 The third digit from the left is different as follows.
 In case of 0 (example: 18 0 01000)
  When the third digit from the left shows "0", this error occurred under the condition of INITIAL SETTINGS has been completed.
  It means that this error is occurred basically at user side.
 In case of 8 (example: 18 8 01000)
  When the third digit from the left shows "8", this error occurred under the condition of INITIAL SETTINGS has been released.                 
  (Example; Factory assembling-line before unit shipment, Service mode etc.)                 
  It means that this error is occurred at service side.
2) About "?" indication: ("18*0 0?01" to "18*0 0?50"):                 
 The third digit from the right shows one of the hexadecimal ("0" to "F") character.
HARD
VENUS A/
D
Flash
28*0
0000
Flash charging error.
STRB CHG
FLASH P.C.B./
FPC
IC6001-(AC16) signal line or Flash charging circuit
FLASH 
ROM
(EEPROM
Area)
FLASH 
ROM
(EEPROM
Area)
2B*0
0001
0003
0004
EEPROM read error
FROM RE
FROM
IC6002 (FLASH ROM)
0002
EEPROM write error
FROM WR
FROM
IC6002 (FLASH ROM)
0005
Firmware version up error
(No indication) (No indication)
Replace the firmware file in the SD memory card.
0008
SDRAM error
0009
SDRAM Mounting defective
SYSTEM
RTC
2C*0
0001
SYSTEM IC initialize failure error
SYS INIT
MAIN P.C.B.
Communication between IC6001 (VENUS ENGINE) 
and IC9101 (SYSTEM)
SOFT
CPU
Reset
30*0
0001
|
0007
NMI reset
Non Mask-able Interrupt
(30000001-30000007 are caused by factors)
NMI RST
MAIN P.C.B.
Card
Card
31*0
0001
Card logic error
SD CARD
SD CARD/
DSP
SD memory card data line or IC6001 (VENUS 
ENGINE)
0002
Card physical error
SD memory card data line or IC6001 (VENUS 
ENGINE)
0004
Write error
SD WRITE
SD memory card data line or IC6001 (VENUS 
ENGINE)
39*0
0005
Format error
INMEMORY
FROM
CPU,
ASIC hard
Stop
38*0
0001
Camera task finish process time out.
LENS COM
LENSu/DSP
Communication between Lens system and IC6001 
(VENUS ENGINE)
0002
Camera task invalid code error.
DSP
DSP
IC6001 (VENUS ENGINE)
0100
File time out error in recording motion image
IC6001 (VENUS ENGINE)
0200
File data cue send error in recording motion image
IC6001 (VENUS ENGINE)
0300
Single or burst recording brake time out.
Memory 
area
3A*0
0008
USB work area partitioning failure
(No indication) (No indication)
USB dynamic memory securing failure when 
connecting
Operation Power on
3B*0
0000
FLASHROM processing early period of camera 
during movement.
INIT
(No indication)
Zoom
Zoom
3C*0
0000
Imperfect zoom lens processing
ZOOM
ZOOMm/
LENSu
Zoom lens
35*0
0000
|
FFFF
Software error
(0-7bit : command, 8-15bit : status)
DSP
DSP
35*1
0000
Though record preprocessing is necessary, it is not 
called.
35*2
0000
Though record preprocessing is necessary, it is not 
completed.
(No indication) (No indication)
Attribute Main item Sub item
Error code
Contents (Upper)
Error Indication
High 4bits Low 4 bits
Check point (Lower)
Detecting
device
Part/Circuit
Page of 90
Display

Click on the first or last page to see other DMC-FT20EE service manuals if exist.