Panasonic VL-G201RU-N / VL-G201RU-S Service Manual ▷ View online

Upper/lower range
     • 
• 
• 
• 
Side view of when the camera is facing the front at 0°.
Left/right range
     • 
• 
• 
• 
Top view of when the camera is facing the front at 0°.
     • 
• 
• 
• 
Top view of when the camera is facing the left at 15°.
     • 
• 
• 
• 
Top view of when the camera is facing the right at 15°.
5 INSTALLATION
5.1. BEFORE INSTALLATION
To avoid malfunction or communication disturbances, do not install either the door station or the monitor station in the following
locations:
     • 
• 
• 
• 
Places where vibration or any other kind of impact occurs.
     • 
• 
• 
• 
Places where echoing is frequent.
     • 
• 
• 
• 
Places where a high concentration of dust, hydrogen sulfide, phosphorus, ammonia, sulfur, carbon, acid, or noxious fumes
occur.
     • 
• 
• 
• 
Within 2 m (6´7") of a TV, microwave, personal computer, air conditioner or any other electrical device.
5.1.1. Standard installation position of the door station and camera range
Note:
     • 
• 
• 
• 
The measurements and angles are for reference purposes and may vary depending on the environment.
     • 
• 
• 
• 
If a strong light is shining on the door station, the visitor’s face may not be distinguishable. Do not place the door station in
the following locations.
     − 
− 
− 
− 
Where most of the background is the sky.
     − 
− 
− 
− 
Where the background is a white wall, and direct sunlight will reflect off it.
     − 
− 
− 
− 
Where direct sunlight will shine on the door station.
     − 
− 
− 
− 
Where echoing occurs, causing the unit to beep frequently.
     • 
• 
• 
• 
Make sure the back of the door station is not subject to water.
5.1.2. Standard installation position of the monitor station
     • 
• 
• 
• 
Place the monitor station in a location so that your eyes are the same height as the center of the display.
Note:
     • 
• 
• 
• 
In areas surrounded by high electrical field, disturbance may occur in the monitor station’s image or sound.
     • 
• 
• 
• 
Be sure to install the monitor station more than 5 m away from the door station.
     • 
• 
• 
• 
Do not place any objects within 20 cm of the monitor station. This may cause communication errors or malfunction.
     • 
• 
• 
• 
Do not install the monitor station inside a wall.
9
VL-G201RU-N / VL-G201RU-S
5.1.3. Wiring schematic diagram
Note:
     • 
• 
• 
• 
The Door Opener wiring schematic diagram is an example. To connect to a Door Opener, make sure the Door Opener is:
     − 
− 
− 
− 
Normal open (Low active)
     − 
− 
− 
− 
Less than AC30 V (1 A), DC24 V (1 A)
     • 
• 
• 
• 
Please see the PBX/Door Opener manuals for further details.
5.1.4. Power cable/wire type and distance
     • 
• 
• 
• 
Power cable (between the monitor station and the AC adaptor):
Type:
1.2 Fire alarm cable 16 AWG
Distance: Maximum 30 m
     • 
• 
• 
• 
Wire (between the monitor station and the door station):
Type: General cable CAT-3 24 AWG
Distance: Maximum 100 m (about 328 feet)
Loop resistance: 18.4
or lower.
     • 
• 
• 
• 
Wire (between the monitor station and PBX):
Type: General cable CAT-3 24 AWG
Distance: Maximum 100 m (about 328 feet)
10
VL-G201RU-N / VL-G201RU-S
5.2. INSTALLING THE DOOR STATION
Make sure to install the door station on a flat, vertical wall.
Important information:
On the bottom surface of the door station, there is a hole to allow water to drain. Do not cover it up when installing.
1. Unscrew the hex-head screw using the longer end of the allen
wrench and remove the mounting bracket from the rear of the door
station.
2. Attach the mounting bracket to the wall using the wood screws (3.8
mm × 20 mm).
     • 
• 
• 
• 
Before drilling, see Standard installation position of the door
station and camera range 
for installation location (P.9).
3. Connect the wires that connect to the monitor station to the terminal
by unscrewing the screws, pushing in the wires, then tightly fastening
the screws.
     • 
• 
• 
• 
See Power cable/wire type and distance for the wire type and
distance (P.10).
     • 
• 
• 
• 
You can change the camera angle using the camera angle control
lever. See Standard installation position of the door station and
camera range 
for details (P.9).
11
VL-G201RU-N / VL-G201RU-S
     • 
• 
• 
• 
If you want to connect the wires without them passing through a
hole in the wall, connect the wires by passing them through the ribs
and the wire hole.
4. Mount the door station to the mounting bracket.
5. Insert the hex-head screw using the longer end of the allen wrench.
6. Attach the bolt cover using the shorter end of the allen wrench.
     • 
• 
• 
• 
Use protrusion on the shorter end of the allen wrench to rotate the
bolt cover until it is secure.
12
VL-G201RU-N / VL-G201RU-S