Panasonic CQ-xxx Service Manual / Other ▷ View online
IDC Module 4 : Removal and Reinstallation of the Stocker block
Part Two,18
Reinstalling the Stocker block
Inspect the
installation for
alignment.
Finish tightening
the cover plate
screws.
Reconnect the
elevator motor
cable to the
control jig.
IDC Module 4 : Removal and Reinstallation of the Stocker block
Part Two,19
Reinstalling the Stocker block
Operate the stocker assembly with the control jig to confirm
that all trays separate evenly.
Caution!
Do not allow tab on stocker Cam Gear #1 to travel
higher than the top plate or lower than the bottom plate. This
will cause the stocker assembly to jam.
IDC Module 4 : Removal and Reinstallation of theStocker block
Part Two,20
Reinstalling the Stocker block
After confirming proper
operation of the stocker
block , turn off the power
supply and disconnect the
control jig. Insert the
ribbon cable into
CN401
.
Insert and tighten the
single
screw
that secures
the stocker switch PCB to
the chassis.
IDC Module 4 : Removal and Reinstallation of the Stocker block
End Module 4
Reinstalling the Stocker block
Reinstall the Upper chassis unit (Module 3).
Confirm that all deck functions are working properly.
Click on the first or last page to see other CQ-xxx service manuals if exist.