DOWNLOAD Panasonic SC-HC37EC / SC-HC37EE / SC-HC37EF / SC-HC37EG Service Manual ↓ Size: 11.51 MB | Pages: 127 in PDF or view online for FREE

Model
SC-HC37EC SC-HC37EE SC-HC37EF SC-HC37EG
Pages
127
Size
11.51 MB
Type
PDF
Document
Service Manual
Brand
Device
Audio / COMPACT STEREO SYSTEM
File
sc-hc37ec-sc-hc37ee-sc-hc37ef-sc-hc37eg.pdf
Date

Panasonic SC-HC37EC / SC-HC37EE / SC-HC37EF / SC-HC37EG Service Manual ▷ View online

17
8.2.
Self Diagnostic Function Error Code
8.2.1.
CD Mechanism Error Code Table
8.2.2.
Power Amp Error Code Table
8.2.3.
iPod Error Code Table
8.2.4.
Sliding Door Operation Error Code Table
 of error
Automatic FL Display
Remarks
CD H15
CD Open Abnormal
During operation 
POS_SW_R On fail to be 
detected within 4 sec. Error 
No. shall be clear by force 
or during cold start.
Press [ ] on main unit for 
next error.
CD H16
CD Closing Abnormal
During operation 
POS_SW_CEN On fail to 
be detected within 4 sec. 
Error No. shall be clear by 
force or during cold start.
Press [ ] on main unit for 
next error.
F26
Communication between 
CD servo LSI and micro-p 
abnormal.
During switch to CD func-
tion, if SENSE = “L” within 
failsafe time of 20ms.
Press [ ] on main unit for 
next error.
Error Code
Diagnostic Contents
Description of error
of error
Automatic FL Display
Remarks
F61/F76
Power Amp IC output
SMPS NG
Checking SMPS Type
abnormal
During power-on, PDET1,
SMPS type and REGION 
not match.
The unit will shutdown.
PDET2 & MAINV_DET /
TEMP_DET is “L” after 1
sec.
Press [ ] on main unit for
next error.
Press [ ] on main unit for
next error.
Error Code
Diagnostic Contents
Description of error
 of error
Automatic FL Display
Remarks
IPD H15
iPod Open Abnormal
During operation 
POS_SW_L On fail to be 
detected within 3 sec. Error 
No. shall be clear by force 
or during cold start.
Press [ ] on main unit for 
next error.
IPD H16
iPod Closing Abnormal
During operation 
POS_SW_CEN On fail to 
be detected within 3 sec. 
Error No. shall be clear by 
force or during cold start.
Press [ ] on main unit for 
next error.
Error Code
Diagnostic Contents
Description  of error
 of error
Automatic FL Display
Remarks
ILLEGAL   OPEN Sliding Door Open/Close 
Abnormal
Refer to 8.4 for more 
information
During Operation
1. Motor set to FREE RUN 
condition after 2 retry fail to 
detect any POS_SW.
2. Sliding Door Stop from 
neutral to iPod open and 
position sensor could not be 
detected.
Press [ ] on main unit for 
next error.
Error Code
Diagnostic Contents
Description  of error
18
8.3.
Doctor Mode Table
Note : To enter the Doctor Mode, please use HC35 remote control.
Here is the procedures to enter into Doctor Mode.
Step 1 : Turn on the unit.
Step 2 : Select CD mode.
Step 3 : Pressing and hold [Q] on main unit then press [4] follow by [7] using the remote control.
Step 4 : The display show as follow.
To exit the Doctor mode
Use either one of the following methods to cancel the Doctor mode.
• Press the power button of the unit or using the remote control.
• Unplug the AC cord.
8.3.1.
Doctor Mode Table 1
Item
FL Display
Key Operation
Mode Name
Description
Front Key
Doctor Mode
To enter into Doctor Mode
for checking of various
items and displaying
EEPROM and firmware ver-
sion.
Note: The micro-processor
version as shown is an
example. It will be revise
when there is an updates.
FL Display sequence Dis-
play 1
2
(Display 1)
Checksum : (Condition 1)
(Display 2)
The Checksum of EEPROM and firmware
version will be display for 2 sec.
In any mode:
Press
 [    ]
button on main unit follow by
[4] & then [7] on the remote control of
HC35.
To exit Doctor Mode, press
[
TA
]
button
on main unit or on the remote control of 
HC35.
Version Display
(DEC)
Check sum
(HEX)
No Rom correction
19
8.3.2.
Doctor Mode Table 2
Item
FL Display
Key Operation
Mode Name
Description
Front Key
FL Display Test
To check the FL segments
display (All segments will
light up)
In Doctor Mode:
Press [1] button on the remote control of
HC35.
To cancel, press [0] button on remote
control. It returns Doctor Mode.
To cancel, press [0] button on remote
control. It returns Doctor Mode.
To cancel, press [0] button on remote
control. It returns Doctor Mode.
To cancel, press [0] button on remote
control. It returns Doctor Mode.
To exit Doctor Mode, press
but-
ton on main unit or on the remote control
of HC35.
Volume Setting
In Doctor Mode:
Press [7] button on the remote control of
HC35.
In Doctor Mode:
Press [8] button on the remote control of
HC35.
In Doctor Mode:
Press [9] button on the remote control of
HC35.
Mecha Sliding Panel
Reliability
In Doctor Mode:
Press [
] follow by [2] & then [1]
button on the remote control of HC35. 
To cancel, press [0] button on remote
control. It returns Doctor Mode.
To exit Doctor Mode, press
but-
ton on main unit or on the remote control
of HC35.
To exit Doctor Mode, press
but-
ton on main unit or on the remote control
of HC35.
To exit Doctor Mode, press
but-
ton on main unit or on the remote control
of HC35.
To exit Doctor Mode, press
but-
ton on main unit or on the remote control
of HC35.
To check the operation of
sliding Panel.
Sequence as follow :
1. CD Door set to CLOSE 
position.
2. CD Door move to the left 
(CD Open direction) and 
stop at LEFT position for 1 
sec.
3. CD Door move to the 
right (CD Close direction) 
and stop at CLOSE position 
for 1 sec.
4. All the process above is 
considered as 1 cycle. Step 
(2) ~ (3) will repeat; Cycle 
Counter display increase 
every 1 cycle completed.
Refer to 8.3.5 for more 
information
To check for preset volume
setting
Note : In tuner mode this
function is not possible
20
8.3.3.
Doctor Mode Table 3
Item
FL Display
Key Operation
Mode Name
Description
Front Key
Cold Start
The [NO DISC] display will appear after 2s,
To display result of self
adjustment for CD.
The [NO DISC] display will appear after 3s,
In Doctor Mode:
Press [
] follow by [1] & then [4] 
button on the remote control of HC35. 
To cancel, press [0] button on remote 
control. It returns Doctor Mode.
To exit Doctor Mode, press 
 but-
ton on main unit or on the remote control 
of HC35.
In Doctor Mode:
Press [
] follow by [1] & then [5] 
button on the remote control of HC35. 
To cancel, press [0] button on remote 
control. It returns Doctor Mode.
To exit Doctor Mode, press 
 but-
ton on main unit or on the remote control 
of HC35.
In Doctor Mode:
Press [SLEEP] button on remote
control. 
To cancel, press [0] button on remote 
control. It returns Doctor Mode.
To exit Doctor Mode, press 
 but-
ton on main unit or on the remote control 
of HC35.
To cancel, press [0] button on remote 
control. It returns Doctor Mode.
To exit Doctor Mode, press 
 but-
ton on main unit or on the remote control 
of HC35.
CD Self-Adjusment 
Display
CD Combination Test
To check the open/close 
operation & inner outer disc 
access operation.
1. It fails when CD 
open/close is not completed 
by 4s.
2. The disc access fails in 
10s.
3. The traverse is out of 
focus for more than 2s.
Refer to 8.3.7 for more 
information
To activate cold start upon 
next power up.
(Backup data are initialized)
EEPROM Checksum
To check sum of EEPROM 
for a simplifield ROM 
correction.
1. When EEPROM is not 
detected, the only micro-p’s 
version shall be displayed 
without an EEPROM’s 
check sum
In any mode:
Press
 [    ] 
button on main unit follow by 
[4] & then [7] on the remote control of 
HC35.
EEPROM not detected only firmware is display
Version Display
(DEC)
Check sum
(HEX)
CD Traverse Test 
Mode
To check for the traverse unit 
operation. In this mode, the 
first & last track is access & 
read. (TOC). It fails when 
TOC is not completed by 10s 
or the traverse is out of 
focus. for more than 2s
Refer to 8.3.6 for more 
information
In Doctor Mode:
Press [
] follow by [1] & 
then [2] 
button on the remote control of HC35. 
To cancel, press [0] button on remote 
control. It returns Doctor Mode.
To exit Doctor Mode, press 
 but-
ton on main unit or on the remote control 
of HC35.
The counter will increment by 1 until reach 
99999999
Page of 127
Display